{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-3235"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-3235","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"REAL TIME 3-D TRACKING OF THE HIGH DOSE RATE RADIATION SOURCE USING A FLAT PANEL DETECTOR","abstract":"A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would follow in real time. The exit radiation of the HDR source was used to image a well defined matrix of markers. The images were acquired using FPD and were processed to obtain projection coordinates while an x-ray calibration image was processed to obtain marker coordinates. Each marker along with its projection represents a line in 3D. A mathematical solution for the ‘near-intersection’ of two 3D lines was implemented and used to determine the ‘true’ 3D source position. A matrix with N markers will produce N*(N-1)/2 points of intersection and their mean will result in a more accurate source position. This study has proved that the accuracy of source position detection using a FPD is sub-millimeter.","abstract_html":"A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would follow in real time. The exit radiation of the HDR source was used to image a well defined matrix of markers. The images were acquired using FPD and were processed to obtain projection coordinates while an x-ray calibration image was processed to obtain marker coordinates. Each marker along with its projection represents a line in 3D. A mathematical solution for the ‘near-intersection’ of two 3D lines was implemented and used to determine the ‘true’ 3D source position. A matrix with N markers will produce N*(N-1)/2 points of intersection and their mean will result in a more accurate source position. This study has proved that the accuracy of source position detection using a FPD is sub-millimeter.","abstract_has_math":false,"creators":["Bondal, Aditya"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Dorin Todor","Ding-Yu Fei"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:09:01Z","subjects":["HDR","Brachytherapy","Flat Panel Detector","Tracking","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/2236"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/2236","href":"https://scholarscompass.vcu.edu/etd/2236","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/DZ74-7T53","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/DZ74-7T53","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-3235","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dorin Todor","Ding-Yu Fei"]},{"key":"dc:creator","label":"Author","values":["Bondal, Aditya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2010-08-04T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["HDR","Brachytherapy","Flat Panel Detector","Tracking","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/DZ74-7T53","https://scholarscompass.vcu.edu/etd/2236"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would follow in real time. The exit radiation of the HDR source was used to image a well defined matrix of markers. The images were acquired using FPD and were processed to obtain projection coordinates while an x-ray calibration image was processed to obtain marker coordinates. Each marker along with its projection represents a line in 3D. A mathematical solution for the ‘near-intersection’ of two 3D lines was implemented and used to determine the ‘true’ 3D source position. A matrix with N markers will produce N*(N-1)/2 points of intersection and their mean will result in a more accurate source position. This study has proved that the accuracy of source position detection using a FPD is sub-millimeter."]},{"key":"dc:title","label":"Title","values":["REAL TIME 3-D TRACKING OF THE HIGH DOSE RATE RADIATION SOURCE USING A FLAT PANEL DETECTOR"]}]}],"canonical_facts":{"dc:contributor":["Dorin Todor","Ding-Yu Fei"],"dc:creator":["Bondal, Aditya"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2010-08-04T07:00:00Z"],"dc:description.abstract":["A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would follow in real time. The exit radiation of the HDR source was used to image a well defined matrix of markers. The images were acquired using FPD and were processed to obtain projection coordinates while an x-ray calibration image was processed to obtain marker coordinates. Each marker along with its projection represents a line in 3D. A mathematical solution for the ‘near-intersection’ of two 3D lines was implemented and used to determine the ‘true’ 3D source position. A matrix with N markers will produce N*(N-1)/2 points of intersection and their mean will result in a more accurate source position. This study has proved that the accuracy of source position detection using a FPD is sub-millimeter."],"dc:identifier":["https://doi.org/10.25772/DZ74-7T53","https://scholarscompass.vcu.edu/etd/2236"],"dc:rights":["© The Author"],"dc:subject":["HDR","Brachytherapy","Flat Panel Detector","Tracking","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["REAL TIME 3-D TRACKING OF THE HIGH DOSE RATE RADIATION SOURCE USING A FLAT PANEL DETECTOR"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:09:01Z"}