{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-3322"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-3322","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy","abstract":"In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking. This paper presents a spatio-temporal model for four dimensional CT reconstruction. The method begins with a set of initial CT projections and a simultaneously acquired breathing trace. Two methods are explored to model the spatial components: principal component analysis and a pseudoinverse matrix method. An iterative approach is used to match the simulated projections to the actual projections. The simulated projections and the initial projections are evaluated using Normalized Root Mean Square Error (NRMSE). The proposed method shows simulated projections and actual projections match, and as such the model is able to accurately predict the deformation.","abstract_html":"In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking. This paper presents a spatio-temporal model for four dimensional CT reconstruction. The method begins with a set of initial CT projections and a simultaneously acquired breathing trace. Two methods are explored to model the spatial components: principal component analysis and a pseudoinverse matrix method. An iterative approach is used to match the simulated projections to the actual projections. The simulated projections and the initial projections are evaluated using Normalized Root Mean Square Error (NRMSE). The proposed method shows simulated projections and actual projections match, and as such the model is able to accurately predict the deformation.","abstract_has_math":false,"creators":["Zachariah, Elizabeth"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Ding-Yu Fei","Alen Docef"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:09:11Z","subjects":["4-D CT","deformation model","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/2323"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/2323","href":"https://scholarscompass.vcu.edu/etd/2323","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/QASM-J609","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/QASM-J609","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-3322","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ding-Yu Fei","Alen Docef"]},{"key":"dc:creator","label":"Author","values":["Zachariah, Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2010-12-10T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["4-D CT","deformation model","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/QASM-J609","https://scholarscompass.vcu.edu/etd/2323"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking. This paper presents a spatio-temporal model for four dimensional CT reconstruction. The method begins with a set of initial CT projections and a simultaneously acquired breathing trace. Two methods are explored to model the spatial components: principal component analysis and a pseudoinverse matrix method. An iterative approach is used to match the simulated projections to the actual projections. The simulated projections and the initial projections are evaluated using Normalized Root Mean Square Error (NRMSE). The proposed method shows simulated projections and actual projections match, and as such the model is able to accurately predict the deformation."]},{"key":"dc:title","label":"Title","values":["4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy"]}]}],"canonical_facts":{"dc:contributor":["Ding-Yu Fei","Alen Docef"],"dc:creator":["Zachariah, Elizabeth"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2010-12-10T08:00:00Z"],"dc:description.abstract":["In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking. This paper presents a spatio-temporal model for four dimensional CT reconstruction. The method begins with a set of initial CT projections and a simultaneously acquired breathing trace. Two methods are explored to model the spatial components: principal component analysis and a pseudoinverse matrix method. An iterative approach is used to match the simulated projections to the actual projections. The simulated projections and the initial projections are evaluated using Normalized Root Mean Square Error (NRMSE). The proposed method shows simulated projections and actual projections match, and as such the model is able to accurately predict the deformation."],"dc:identifier":["https://doi.org/10.25772/QASM-J609","https://scholarscompass.vcu.edu/etd/2323"],"dc:rights":["© The Author"],"dc:subject":["4-D CT","deformation model","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:09:11Z"}