{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-3514"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-3514","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Characterization of Lysophosphatidic Acid Subspecies Using a Novel HPLC ESI-MS/MS Method","abstract":"Lysophosphatidic acid (LPA) is a bioactive lipid with a plethora of biological functions, including roles in cell survival, proliferation, and migration. Although high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC ESI-MS/MS) technology has been used to measure the levels of LPA in human blood, serum and plasma, current methods cannot readily detect the minute levels of LPA from cell culture. In this study, a novel HPLC ESI-MS/MS method with enhanced sensitivity was developed which allows accurate measurements of LPA levels with a limit of quantitation at approximately 10 femtomoles. The method was validated by quantitation of LPA levels in the media of previously characterized cell lines ectopically expressing autotaxin. Autotaxin overexpression induced an increase in several subspecies of LPA while others remained unchanged. Lastly, this HPLC ESI-MS/MS method was validated via biological assays previously utilized to assay LPA production. Hence, this new HPLC ESI-MS/MS will allow researchers to measure in vitro LPA levels and also distinguish between specific LPA subspecies for the delineation of individual biological mechanisms.","abstract_html":"Lysophosphatidic acid (LPA) is a bioactive lipid with a plethora of biological functions, including roles in cell survival, proliferation, and migration. Although high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC ESI-MS/MS) technology has been used to measure the levels of LPA in human blood, serum and plasma, current methods cannot readily detect the minute levels of LPA from cell culture. In this study, a novel HPLC ESI-MS/MS method with enhanced sensitivity was developed which allows accurate measurements of LPA levels with a limit of quantitation at approximately 10 femtomoles. The method was validated by quantitation of LPA levels in the media of previously characterized cell lines ectopically expressing autotaxin. Autotaxin overexpression induced an increase in several subspecies of LPA while others remained unchanged. Lastly, this HPLC ESI-MS/MS method was validated via biological assays previously utilized to assay LPA production. Hence, this new HPLC ESI-MS/MS will allow researchers to measure in vitro LPA levels and also distinguish between specific LPA subspecies for the delineation of individual biological mechanisms.","abstract_has_math":false,"creators":["Mayton, Eric"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biochemistry","degree_department":null,"school":null,"contributors":["Charles Chalfant"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:09:17Z","subjects":["Lysophosphatidic Acid","HPLC ESI-MS/MS","Biochemistry, Biophysics, and Structural Biology","Life Sciences"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/2515"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/2515","href":"https://scholarscompass.vcu.edu/etd/2515","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/2D7H-MH88","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/2D7H-MH88","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-3514","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Charles Chalfant"]},{"key":"dc:creator","label":"Author","values":["Mayton, Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-07-14T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biochemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lysophosphatidic Acid","HPLC ESI-MS/MS","Biochemistry, Biophysics, and Structural Biology","Life Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/2D7H-MH88","https://scholarscompass.vcu.edu/etd/2515"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lysophosphatidic acid (LPA) is a bioactive lipid with a plethora of biological functions, including roles in cell survival, proliferation, and migration. Although high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC ESI-MS/MS) technology has been used to measure the levels of LPA in human blood, serum and plasma, current methods cannot readily detect the minute levels of LPA from cell culture. In this study, a novel HPLC ESI-MS/MS method with enhanced sensitivity was developed which allows accurate measurements of LPA levels with a limit of quantitation at approximately 10 femtomoles. The method was validated by quantitation of LPA levels in the media of previously characterized cell lines ectopically expressing autotaxin. Autotaxin overexpression induced an increase in several subspecies of LPA while others remained unchanged. Lastly, this HPLC ESI-MS/MS method was validated via biological assays previously utilized to assay LPA production. Hence, this new HPLC ESI-MS/MS will allow researchers to measure in vitro LPA levels and also distinguish between specific LPA subspecies for the delineation of individual biological mechanisms."]},{"key":"dc:title","label":"Title","values":["Characterization of Lysophosphatidic Acid Subspecies Using a Novel HPLC ESI-MS/MS Method"]}]}],"canonical_facts":{"dc:contributor":["Charles Chalfant"],"dc:creator":["Mayton, Eric"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2011-07-14T07:00:00Z"],"dc:description.abstract":["Lysophosphatidic acid (LPA) is a bioactive lipid with a plethora of biological functions, including roles in cell survival, proliferation, and migration. Although high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC ESI-MS/MS) technology has been used to measure the levels of LPA in human blood, serum and plasma, current methods cannot readily detect the minute levels of LPA from cell culture. In this study, a novel HPLC ESI-MS/MS method with enhanced sensitivity was developed which allows accurate measurements of LPA levels with a limit of quantitation at approximately 10 femtomoles. The method was validated by quantitation of LPA levels in the media of previously characterized cell lines ectopically expressing autotaxin. Autotaxin overexpression induced an increase in several subspecies of LPA while others remained unchanged. Lastly, this HPLC ESI-MS/MS method was validated via biological assays previously utilized to assay LPA production. Hence, this new HPLC ESI-MS/MS will allow researchers to measure in vitro LPA levels and also distinguish between specific LPA subspecies for the delineation of individual biological mechanisms."],"dc:identifier":["https://doi.org/10.25772/2D7H-MH88","https://scholarscompass.vcu.edu/etd/2515"],"dc:rights":["© The Author"],"dc:subject":["Lysophosphatidic Acid","HPLC ESI-MS/MS","Biochemistry, Biophysics, and Structural Biology","Life Sciences"],"dc:title":["Characterization of Lysophosphatidic Acid Subspecies Using a Novel HPLC ESI-MS/MS Method"],"thesis:degree_discipline":["Biochemistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:09:17Z"}