{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-3548"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-3548","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"The Effect of Insulating K-Type Files on Accuracy and Reliability as Used in Two Electronic Apex Locators","abstract":"The purpose of this in-vitro study is to compare the accuracy and reliability of a 3rd and 4th generation electronic apex locator (EAL) in locating the apical foramen when using insulated and non-insulated K files. Forty extracted human adult single-rooted teeth were coronally sectioned and placed in agar. EAL determined tooth length measurements were compared to actual tooth measurements. Comparisons to the standard measures used correlation and paired t-test. Preliminary comparisons of the groups used ANOVA to compare the means and the Brown-Forsythe test to compare variance. In the final analyses, the measurements were compared using a repeated-measures mixed-model multiway ANOVA that allowed for heterogeneous variance in the subgroups. Findings were that accuracy is not different due to insulation in the Root ZX group (p-value=0.50) but is improved in the Elements Diagnostic Unit group (p-value<.001). Reliability is nominally improved with insulation in both the Root ZX and Elements Diagnostic Unit.","abstract_html":"The purpose of this in-vitro study is to compare the accuracy and reliability of a 3rd and 4th generation electronic apex locator (EAL) in locating the apical foramen when using insulated and non-insulated K files. Forty extracted human adult single-rooted teeth were coronally sectioned and placed in agar. EAL determined tooth length measurements were compared to actual tooth measurements. Comparisons to the standard measures used correlation and paired t-test. Preliminary comparisons of the groups used ANOVA to compare the means and the Brown-Forsythe test to compare variance. In the final analyses, the measurements were compared using a repeated-measures mixed-model multiway ANOVA that allowed for heterogeneous variance in the subgroups. Findings were that accuracy is not different due to insulation in the Root ZX group (p-value=0.50) but is improved in the Elements Diagnostic Unit group (p-value&lt;.001). Reliability is nominally improved with insulation in both the Root ZX and Elements Diagnostic Unit.","abstract_has_math":false,"creators":["Finkler, Timothy"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Karan Replogle","Samuel Black"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:09:24Z","subjects":["electronic apex locator","Dentistry","Medicine and Health Sciences"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/2549"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/2549","href":"https://scholarscompass.vcu.edu/etd/2549","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/P150-WG74","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/P150-WG74","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-3548","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Karan Replogle","Samuel Black"]},{"key":"dc:creator","label":"Author","values":["Finkler, Timothy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-05-06T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electronic apex locator","Dentistry","Medicine and Health Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/P150-WG74","https://scholarscompass.vcu.edu/etd/2549"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this in-vitro study is to compare the accuracy and reliability of a 3rd and 4th generation electronic apex locator (EAL) in locating the apical foramen when using insulated and non-insulated K files. Forty extracted human adult single-rooted teeth were coronally sectioned and placed in agar. EAL determined tooth length measurements were compared to actual tooth measurements. Comparisons to the standard measures used correlation and paired t-test. Preliminary comparisons of the groups used ANOVA to compare the means and the Brown-Forsythe test to compare variance. In the final analyses, the measurements were compared using a repeated-measures mixed-model multiway ANOVA that allowed for heterogeneous variance in the subgroups. Findings were that accuracy is not different due to insulation in the Root ZX group (p-value=0.50) but is improved in the Elements Diagnostic Unit group (p-value<.001). Reliability is nominally improved with insulation in both the Root ZX and Elements Diagnostic Unit."]},{"key":"dc:title","label":"Title","values":["The Effect of Insulating K-Type Files on Accuracy and Reliability as Used in Two Electronic Apex Locators"]}]}],"canonical_facts":{"dc:contributor":["Karan Replogle","Samuel Black"],"dc:creator":["Finkler, Timothy"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2011-05-06T07:00:00Z"],"dc:description.abstract":["The purpose of this in-vitro study is to compare the accuracy and reliability of a 3rd and 4th generation electronic apex locator (EAL) in locating the apical foramen when using insulated and non-insulated K files. Forty extracted human adult single-rooted teeth were coronally sectioned and placed in agar. EAL determined tooth length measurements were compared to actual tooth measurements. Comparisons to the standard measures used correlation and paired t-test. Preliminary comparisons of the groups used ANOVA to compare the means and the Brown-Forsythe test to compare variance. In the final analyses, the measurements were compared using a repeated-measures mixed-model multiway ANOVA that allowed for heterogeneous variance in the subgroups. Findings were that accuracy is not different due to insulation in the Root ZX group (p-value=0.50) but is improved in the Elements Diagnostic Unit group (p-value<.001). Reliability is nominally improved with insulation in both the Root ZX and Elements Diagnostic Unit."],"dc:identifier":["https://doi.org/10.25772/P150-WG74","https://scholarscompass.vcu.edu/etd/2549"],"dc:rights":["© The Author"],"dc:subject":["electronic apex locator","Dentistry","Medicine and Health Sciences"],"dc:title":["The Effect of Insulating K-Type Files on Accuracy and Reliability as Used in Two Electronic Apex Locators"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:09:24Z"}