{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-4272"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-4272","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Spectral Analysis of Nonstationary Heart Rate of Neonates Receiving Therapeutic Hypothermia Treatment","abstract":"We studied Heart Rate Variability (HRV) evolution during therapeutic hypothermia in newborns with hypoxic ischemic encephalopathy (HIE) using spectral analysis. We hypothesized that HRV measures are predictive of neurological outcome in babies with HIE. Non-stationarity in the data causes inaccurate quantification of the spectral power. A modification was proposed to power spectral analysis approach to mitigate the effect of non-stationarity. The modified and the standard approaches were applied to cardiac beat-to-beat intervals of newborns receiving hypothermia treatment. The performance of the approaches in distinguishing the RRi dynamics of two groups of newborns was assessed using area under the receiver operating characteristic (ROC) curve. Our results showed that the modified spectral analysis distinguished the two groups of neonates better than the standard approach. These results may be useful in identifying the deteriorating physiology of the infants receiving hypothermia treatment early in time and strategize alternate interventions for them.","abstract_html":"We studied Heart Rate Variability (HRV) evolution during therapeutic hypothermia in newborns with hypoxic ischemic encephalopathy (HIE) using spectral analysis. We hypothesized that HRV measures are predictive of neurological outcome in babies with HIE. Non-stationarity in the data causes inaccurate quantification of the spectral power. A modification was proposed to power spectral analysis approach to mitigate the effect of non-stationarity. The modified and the standard approaches were applied to cardiac beat-to-beat intervals of newborns receiving hypothermia treatment. The performance of the approaches in distinguishing the RRi dynamics of two groups of newborns was assessed using area under the receiver operating characteristic (ROC) curve. Our results showed that the modified spectral analysis distinguished the two groups of neonates better than the standard approach. These results may be useful in identifying the deteriorating physiology of the infants receiving hypothermia treatment early in time and strategize alternate interventions for them.","abstract_has_math":false,"creators":["Al-Shargabi, Tareq"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Ou Bai"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:10:12Z","subjects":["Hypoxic Ischemic Encephalopathy","Heart Rate Variability","Fast Fourier Transform","Spectral Analysis","RR Interval","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/3273"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/3273","href":"https://scholarscompass.vcu.edu/etd/3273","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/MY9M-YF13","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/MY9M-YF13","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-4272","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ou Bai"]},{"key":"dc:creator","label":"Author","values":["Al-Shargabi, Tareq"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-11-26T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hypoxic Ischemic Encephalopathy","Heart Rate Variability","Fast Fourier Transform","Spectral Analysis","RR Interval","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/MY9M-YF13","https://scholarscompass.vcu.edu/etd/3273"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["We studied Heart Rate Variability (HRV) evolution during therapeutic hypothermia in newborns with hypoxic ischemic encephalopathy (HIE) using spectral analysis. We hypothesized that HRV measures are predictive of neurological outcome in babies with HIE. Non-stationarity in the data causes inaccurate quantification of the spectral power. A modification was proposed to power spectral analysis approach to mitigate the effect of non-stationarity. The modified and the standard approaches were applied to cardiac beat-to-beat intervals of newborns receiving hypothermia treatment. The performance of the approaches in distinguishing the RRi dynamics of two groups of newborns was assessed using area under the receiver operating characteristic (ROC) curve. Our results showed that the modified spectral analysis distinguished the two groups of neonates better than the standard approach. These results may be useful in identifying the deteriorating physiology of the infants receiving hypothermia treatment early in time and strategize alternate interventions for them."]},{"key":"dc:title","label":"Title","values":["Spectral Analysis of Nonstationary Heart Rate of Neonates Receiving Therapeutic Hypothermia Treatment"]}]}],"canonical_facts":{"dc:contributor":["Ou Bai"],"dc:creator":["Al-Shargabi, Tareq"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2013-11-26T08:00:00Z"],"dc:description.abstract":["We studied Heart Rate Variability (HRV) evolution during therapeutic hypothermia in newborns with hypoxic ischemic encephalopathy (HIE) using spectral analysis. We hypothesized that HRV measures are predictive of neurological outcome in babies with HIE. Non-stationarity in the data causes inaccurate quantification of the spectral power. A modification was proposed to power spectral analysis approach to mitigate the effect of non-stationarity. The modified and the standard approaches were applied to cardiac beat-to-beat intervals of newborns receiving hypothermia treatment. The performance of the approaches in distinguishing the RRi dynamics of two groups of newborns was assessed using area under the receiver operating characteristic (ROC) curve. Our results showed that the modified spectral analysis distinguished the two groups of neonates better than the standard approach. These results may be useful in identifying the deteriorating physiology of the infants receiving hypothermia treatment early in time and strategize alternate interventions for them."],"dc:identifier":["https://doi.org/10.25772/MY9M-YF13","https://scholarscompass.vcu.edu/etd/3273"],"dc:rights":["© The Author"],"dc:subject":["Hypoxic Ischemic Encephalopathy","Heart Rate Variability","Fast Fourier Transform","Spectral Analysis","RR Interval","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["Spectral Analysis of Nonstationary Heart Rate of Neonates Receiving Therapeutic Hypothermia Treatment"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:10:12Z"}