{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-4332"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-4332","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Using CBCT as a diagnostic tool for evaluation of infrabony defects in vivo","abstract":"BACKGROUND: Clinicians rely on radiographs and clinical exam to assess infrabony defects. However, two-dimensional radiographs have many limitations. Three-dimensional imaging has shown promise and has provided more precise measurements of defects created in skulls. The aim of this study is to compare the diagnostic efficacy of cone beam computed tomography to clinical measurements in patients presenting with infrabony defects. METHODS: The study population included 20 patients with 25 infrabony defects. Clinical measurements of pocket depth (PD), gingival margin (GM), bone sounding (BS) were obtained and PD and BS were compared to CBCT measurements. RESULTS: The average difference between the means of measurements obtained by BS and by CBCT was 1.08mm with BS always being the greater value. BS measurement was statistically significantly different with p<0.05 from CAL and CBCT values. CONCLUSION: The CBCT provided measurements that are on average 1.08mm smaller than bone sounding measurements.","abstract_html":"BACKGROUND: Clinicians rely on radiographs and clinical exam to assess infrabony defects. However, two-dimensional radiographs have many limitations. Three-dimensional imaging has shown promise and has provided more precise measurements of defects created in skulls. The aim of this study is to compare the diagnostic efficacy of cone beam computed tomography to clinical measurements in patients presenting with infrabony defects. METHODS: The study population included 20 patients with 25 infrabony defects. Clinical measurements of pocket depth (PD), gingival margin (GM), bone sounding (BS) were obtained and PD and BS were compared to CBCT measurements. RESULTS: The average difference between the means of measurements obtained by BS and by CBCT was 1.08mm with BS always being the greater value. BS measurement was statistically significantly different with p&lt;0.05 from CAL and CBCT values. CONCLUSION: The CBCT provided measurements that are on average 1.08mm smaller than bone sounding measurements.","abstract_has_math":false,"creators":["Rost, Anya"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Thomas Waldrop"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:10:18Z","subjects":["CBCT","Conebeam computed tomography","infrabony defect","periodontal defect","Dentistry","Medicine and Health Sciences"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/3333"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/3333","href":"https://scholarscompass.vcu.edu/etd/3333","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/RA9N-1N91","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/RA9N-1N91","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-4332","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Thomas Waldrop"]},{"key":"dc:creator","label":"Author","values":["Rost, Anya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-04-14T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CBCT","Conebeam computed tomography","infrabony defect","periodontal defect","Dentistry","Medicine and Health Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/RA9N-1N91","https://scholarscompass.vcu.edu/etd/3333"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["BACKGROUND: Clinicians rely on radiographs and clinical exam to assess infrabony defects. However, two-dimensional radiographs have many limitations. Three-dimensional imaging has shown promise and has provided more precise measurements of defects created in skulls. The aim of this study is to compare the diagnostic efficacy of cone beam computed tomography to clinical measurements in patients presenting with infrabony defects. METHODS: The study population included 20 patients with 25 infrabony defects. Clinical measurements of pocket depth (PD), gingival margin (GM), bone sounding (BS) were obtained and PD and BS were compared to CBCT measurements. RESULTS: The average difference between the means of measurements obtained by BS and by CBCT was 1.08mm with BS always being the greater value. BS measurement was statistically significantly different with p<0.05 from CAL and CBCT values. CONCLUSION: The CBCT provided measurements that are on average 1.08mm smaller than bone sounding measurements."]},{"key":"dc:title","label":"Title","values":["Using CBCT as a diagnostic tool for evaluation of infrabony defects in vivo"]}]}],"canonical_facts":{"dc:contributor":["Thomas Waldrop"],"dc:creator":["Rost, Anya"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2014-04-14T07:00:00Z"],"dc:description.abstract":["BACKGROUND: Clinicians rely on radiographs and clinical exam to assess infrabony defects. However, two-dimensional radiographs have many limitations. Three-dimensional imaging has shown promise and has provided more precise measurements of defects created in skulls. The aim of this study is to compare the diagnostic efficacy of cone beam computed tomography to clinical measurements in patients presenting with infrabony defects. METHODS: The study population included 20 patients with 25 infrabony defects. Clinical measurements of pocket depth (PD), gingival margin (GM), bone sounding (BS) were obtained and PD and BS were compared to CBCT measurements. RESULTS: The average difference between the means of measurements obtained by BS and by CBCT was 1.08mm with BS always being the greater value. BS measurement was statistically significantly different with p<0.05 from CAL and CBCT values. CONCLUSION: The CBCT provided measurements that are on average 1.08mm smaller than bone sounding measurements."],"dc:identifier":["https://doi.org/10.25772/RA9N-1N91","https://scholarscompass.vcu.edu/etd/3333"],"dc:rights":["© The Author"],"dc:subject":["CBCT","Conebeam computed tomography","infrabony defect","periodontal defect","Dentistry","Medicine and Health Sciences"],"dc:title":["Using CBCT as a diagnostic tool for evaluation of infrabony defects in vivo"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:10:18Z"}