{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-4563"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-4563","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"An Investigation of NURBS-Based Deformable Image Registration","abstract":"Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation known as a Non-Uniform Rational B-Splines (NURBS). Beginning with the 1D fitting, heuristic rules are developed to determine the values of the additional free parameters introduced by NURBS. These rules are subsequently modified and extended to the 2D and 3D fitting of anonymized and publicly available patient DVFs. Based on the lessons learned from these increasingly complex test cases, a 2D DIR scheme is developed and tested on slices from a thoracic computed tomography (CT) scan. Finally, an automatic, non-uniform scheme is presented, and its registration performance is compared to the conventional uniform methods.","abstract_html":"Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation known as a Non-Uniform Rational B-Splines (NURBS). Beginning with the 1D fitting, heuristic rules are developed to determine the values of the additional free parameters introduced by NURBS. These rules are subsequently modified and extended to the 2D and 3D fitting of anonymized and publicly available patient DVFs. Based on the lessons learned from these increasingly complex test cases, a 2D DIR scheme is developed and tested on slices from a thoracic computed tomography (CT) scan. Finally, an automatic, non-uniform scheme is presented, and its registration performance is compared to the conventional uniform methods.","abstract_has_math":false,"creators":["Jacobson, Travis J"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"Thesis","degree_discipline":"Medical Physics","degree_department":null,"school":null,"contributors":["Martin J Murphy","Geoffrey D Hugo","Jeffrey F Williamson","Alan Docef"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:10:32Z","subjects":["DIR","B-splines","Deformable Image Registration","NURBS","Image Processing","Other Medical Sciences","Other Medicine and Health Sciences","Other Physics","Radiology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/3563"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/3563","href":"https://scholarscompass.vcu.edu/etd/3563","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/J349-DH36","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/J349-DH36","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-4563","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Martin J Murphy","Geoffrey D Hugo","Jeffrey F Williamson","Alan Docef"]},{"key":"dc:creator","label":"Author","values":["Jacobson, Travis J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-21T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["DIR","B-splines","Deformable Image Registration","NURBS","Image Processing","Other Medical Sciences","Other Medicine and Health Sciences","Other Physics","Radiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/J349-DH36","https://scholarscompass.vcu.edu/etd/3563"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation known as a Non-Uniform Rational B-Splines (NURBS). Beginning with the 1D fitting, heuristic rules are developed to determine the values of the additional free parameters introduced by NURBS. These rules are subsequently modified and extended to the 2D and 3D fitting of anonymized and publicly available patient DVFs. Based on the lessons learned from these increasingly complex test cases, a 2D DIR scheme is developed and tested on slices from a thoracic computed tomography (CT) scan. Finally, an automatic, non-uniform scheme is presented, and its registration performance is compared to the conventional uniform methods."]},{"key":"dc:title","label":"Title","values":["An Investigation of NURBS-Based Deformable Image Registration"]}]}],"canonical_facts":{"dc:contributor":["Martin J Murphy","Geoffrey D Hugo","Jeffrey F Williamson","Alan Docef"],"dc:creator":["Jacobson, Travis J"],"dc:date.available":["2014-08-21T07:00:00Z"],"dc:date.created":["2014-01-01T08:00:00Z"],"dc:description.abstract":["Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation known as a Non-Uniform Rational B-Splines (NURBS). Beginning with the 1D fitting, heuristic rules are developed to determine the values of the additional free parameters introduced by NURBS. These rules are subsequently modified and extended to the 2D and 3D fitting of anonymized and publicly available patient DVFs. Based on the lessons learned from these increasingly complex test cases, a 2D DIR scheme is developed and tested on slices from a thoracic computed tomography (CT) scan. Finally, an automatic, non-uniform scheme is presented, and its registration performance is compared to the conventional uniform methods."],"dc:identifier":["https://doi.org/10.25772/J349-DH36","https://scholarscompass.vcu.edu/etd/3563"],"dc:rights":["© The Author"],"dc:subject":["DIR","B-splines","Deformable Image Registration","NURBS","Image Processing","Other Medical Sciences","Other Medicine and Health Sciences","Other Physics","Radiology"],"dc:title":["An Investigation of NURBS-Based Deformable Image Registration"],"thesis:degree_discipline":["Medical Physics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-11-19T09:10:32Z"}