{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-5341"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-5341","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"QUANTITATIVE ANALYSIS OF 5-CHLORO-2-METHOXY-N-[2-(4-SULFAMOYLPHENYL)ETHYL]BENZAMIDE (GLYBURIDE ANALOGUE, GA) IN MOUSE PLASMA AND WHOLE BLOOD USING A MICRO-EXTRACTION AND LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY","abstract":"Pharmacokinetic evaluation of 5-chloro-2-methoxy-N-[2-(4- sulfamoylphenyl)ethyl]benzamide in mouse plasma demanded for a suitable bioanalytical method. No reported bioanalytical method exists to-date that can quantify concentration of this compound in any biological matrix. The purpose of this study was 1) to develop and validate a new bioanalytical method using a micro-extraction and LC-MS/MS to quantify the target analyte in mouse plasma and 2) to partially validate the method in whole blood. A bioanalytical method was developed and validated in both matrices for a linear concentration range of 2-1000 ng/ml. For both matrices, the reverse predicted concentration of calibration standards (-8.95% to 12.16% and -9.54% to 12.90% respectively) and precision and accuracy (QCs) were within ±15% (%RSD and %BIAS). Four-hour bench top stability and post preparative stability results for plasma and whole blood matrices were within ±15% and ±20% respectively. Blood –plasma concentration correlation co-efficient was 0.9956 with a slope value of 1.018.","abstract_html":"Pharmacokinetic evaluation of 5-chloro-2-methoxy-N-[2-(4- sulfamoylphenyl)ethyl]benzamide in mouse plasma demanded for a suitable bioanalytical method. No reported bioanalytical method exists to-date that can quantify concentration of this compound in any biological matrix. The purpose of this study was 1) to develop and validate a new bioanalytical method using a micro-extraction and LC-MS/MS to quantify the target analyte in mouse plasma and 2) to partially validate the method in whole blood. A bioanalytical method was developed and validated in both matrices for a linear concentration range of 2-1000 ng/ml. For both matrices, the reverse predicted concentration of calibration standards (-8.95% to 12.16% and -9.54% to 12.90% respectively) and precision and accuracy (QCs) were within ±15% (%RSD and %BIAS). Four-hour bench top stability and post preparative stability results for plasma and whole blood matrices were within ±15% and ±20% respectively. Blood –plasma concentration correlation co-efficient was 0.9956 with a slope value of 1.018.","abstract_has_math":false,"creators":["Zalavadia, Ankit"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Pharmaceutical Sciences","degree_department":null,"school":null,"contributors":["Dr. Matthew S Halquist","Dr. Thomas H. Karnes","Dr. Sarah Rutan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:11:25Z","subjects":["Other Pharmacy and Pharmaceutical Sciences"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/4279"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/4279","href":"https://scholarscompass.vcu.edu/etd/4279","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/S5W8-0P17","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/S5W8-0P17","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-5341","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Matthew S Halquist","Dr. Thomas H. Karnes","Dr. Sarah Rutan"]},{"key":"dc:creator","label":"Author","values":["Zalavadia, Ankit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Pharmaceutical Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Other Pharmacy and Pharmaceutical Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/S5W8-0P17","https://scholarscompass.vcu.edu/etd/4279"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Pharmacokinetic evaluation of 5-chloro-2-methoxy-N-[2-(4- sulfamoylphenyl)ethyl]benzamide in mouse plasma demanded for a suitable bioanalytical method. No reported bioanalytical method exists to-date that can quantify concentration of this compound in any biological matrix. The purpose of this study was 1) to develop and validate a new bioanalytical method using a micro-extraction and LC-MS/MS to quantify the target analyte in mouse plasma and 2) to partially validate the method in whole blood. A bioanalytical method was developed and validated in both matrices for a linear concentration range of 2-1000 ng/ml. For both matrices, the reverse predicted concentration of calibration standards (-8.95% to 12.16% and -9.54% to 12.90% respectively) and precision and accuracy (QCs) were within ±15% (%RSD and %BIAS). Four-hour bench top stability and post preparative stability results for plasma and whole blood matrices were within ±15% and ±20% respectively. Blood –plasma concentration correlation co-efficient was 0.9956 with a slope value of 1.018."]},{"key":"dc:title","label":"Title","values":["QUANTITATIVE ANALYSIS OF 5-CHLORO-2-METHOXY-N-[2-(4-SULFAMOYLPHENYL)ETHYL]BENZAMIDE (GLYBURIDE ANALOGUE, GA) IN MOUSE PLASMA AND WHOLE BLOOD USING A MICRO-EXTRACTION AND LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY"]}]}],"canonical_facts":{"dc:contributor":["Dr. Matthew S Halquist","Dr. Thomas H. Karnes","Dr. Sarah Rutan"],"dc:creator":["Zalavadia, Ankit"],"dc:date.available":["2016-05-13T07:00:00Z"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["Pharmacokinetic evaluation of 5-chloro-2-methoxy-N-[2-(4- sulfamoylphenyl)ethyl]benzamide in mouse plasma demanded for a suitable bioanalytical method. No reported bioanalytical method exists to-date that can quantify concentration of this compound in any biological matrix. The purpose of this study was 1) to develop and validate a new bioanalytical method using a micro-extraction and LC-MS/MS to quantify the target analyte in mouse plasma and 2) to partially validate the method in whole blood. A bioanalytical method was developed and validated in both matrices for a linear concentration range of 2-1000 ng/ml. For both matrices, the reverse predicted concentration of calibration standards (-8.95% to 12.16% and -9.54% to 12.90% respectively) and precision and accuracy (QCs) were within ±15% (%RSD and %BIAS). Four-hour bench top stability and post preparative stability results for plasma and whole blood matrices were within ±15% and ±20% respectively. Blood –plasma concentration correlation co-efficient was 0.9956 with a slope value of 1.018."],"dc:identifier":["https://doi.org/10.25772/S5W8-0P17","https://scholarscompass.vcu.edu/etd/4279"],"dc:rights":["© The Author"],"dc:subject":["Other Pharmacy and Pharmaceutical Sciences"],"dc:title":["QUANTITATIVE ANALYSIS OF 5-CHLORO-2-METHOXY-N-[2-(4-SULFAMOYLPHENYL)ETHYL]BENZAMIDE (GLYBURIDE ANALOGUE, GA) IN MOUSE PLASMA AND WHOLE BLOOD USING A MICRO-EXTRACTION AND LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY"],"thesis:degree_discipline":["Pharmaceutical Sciences"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:11:25Z"}