{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-5430"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-5430","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Efficiency of the Thermal Jacket on the Delivered Temperature of Prewarmed Crystalloid Intravenous Fluid","abstract":"A quasi-experimental research design was used to determine the relationship between the flow rate and the delivered temperature of prewarmed crystalloid intravenous solutions when using the Thermal Jacket™, an insulation device designed for intravenous fluid bags, as compared to a conventional blood warming apparatus. One control and three experimental groups were used. Fluids in Group 1 (control group), Group 2, and Group 4 were prewarmed in a microwave oven to 41.45 ± 1.05 ° C. Fluids in Group 3 were left near ambient room temperature and measured at 22.05 ± 0.45 ° C. Fluids in the control group were infused through a standard intravenous pump tubing, 270 em in length, using no temperature maintenance device. Fluids in Group 2 and Group 3 were delivered through a standard intravenous pump tubing connected to a blood warming coil which was immersed in a water bath blood warmer. The distance from the exit point of the blood warmer to the distal end of the infusion line measured 174 em. Fluids in Group 4 were placed in a Thermal Jacket™ and delivered through standard intravenous pump tubing. After a baseline measurement, temperatures were recorded for all groups at two sites at 10 minute intervals over a 60 minute period. One site was the lower portion of the IV solution bag, and the other site was a point 2 em from the distal end of the infusion set. Temperatures were measured at flow rates of 100, 250, 500, 750, and 1,000 ml/hr for each group. Analysis of variance showed a highly significant group effect on the delivered temperature. A Bonferroni multiple comparisons test indicated no statistically significant difference between the delivered temperatures of Group 3 (room temperature fluid + blood warmer) and Group 4 (prewarmed fluid + Thermal Jacket™). Group 2 (prewarmed fluid + blood warmer) showed a significantly higher delivered temperature (p < .05) than the other groups, and the control group (prewarmed + no temperature maintenance device) showed a significantly lower delivered temperature (12. < .05). Analysis of variance also showed a highly significant flow rate effect on delivered temperature. A Bonferroni multiple comparisons indicated a significant difference (12. < .05) between the flow rates of 100, 250, 500, and 750 ml/hr, with the higher flow rates resulting in higher delivered temperatures. There was no significant difference noted between the delivered temperatures at 750 and 1,000 ml/hr. The Thermal Jacket™, used with prewarmed intravenous fluids, was as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a higher delivered temperature.","abstract_html":"A quasi-experimental research design was used to determine the relationship between the flow rate and the delivered temperature of prewarmed crystalloid intravenous solutions when using the Thermal Jacket™, an insulation device designed for intravenous fluid bags, as compared to a conventional blood warming apparatus. One control and three experimental groups were used. Fluids in Group 1 (control group), Group 2, and Group 4 were prewarmed in a microwave oven to 41.45 ± 1.05 ° C. Fluids in Group 3 were left near ambient room temperature and measured at 22.05 ± 0.45 ° C. Fluids in the control group were infused through a standard intravenous pump tubing, 270 em in length, using no temperature maintenance device. Fluids in Group 2 and Group 3 were delivered through a standard intravenous pump tubing connected to a blood warming coil which was immersed in a water bath blood warmer. The distance from the exit point of the blood warmer to the distal end of the infusion line measured 174 em. Fluids in Group 4 were placed in a Thermal Jacket™ and delivered through standard intravenous pump tubing. After a baseline measurement, temperatures were recorded for all groups at two sites at 10 minute intervals over a 60 minute period. One site was the lower portion of the IV solution bag, and the other site was a point 2 em from the distal end of the infusion set. Temperatures were measured at flow rates of 100, 250, 500, 750, and 1,000 ml/hr for each group. Analysis of variance showed a highly significant group effect on the delivered temperature. A Bonferroni multiple comparisons test indicated no statistically significant difference between the delivered temperatures of Group 3 (room temperature fluid + blood warmer) and Group 4 (prewarmed fluid + Thermal Jacket™). Group 2 (prewarmed fluid + blood warmer) showed a significantly higher delivered temperature (p &lt; .05) than the other groups, and the control group (prewarmed + no temperature maintenance device) showed a significantly lower delivered temperature (12. &lt; .05). Analysis of variance also showed a highly significant flow rate effect on delivered temperature. A Bonferroni multiple comparisons indicated a significant difference (12. &lt; .05) between the flow rates of 100, 250, 500, and 750 ml/hr, with the higher flow rates resulting in higher delivered temperatures. There was no significant difference noted between the delivered temperatures at 750 and 1,000 ml/hr. The Thermal Jacket™, used with prewarmed intravenous fluids, was as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a higher delivered temperature.","abstract_has_math":false,"creators":["Bowen, Danny R."],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Health Related Sciences","degree_department":null,"school":null,"contributors":["John T. Beeston"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:11:33Z","subjects":["Nursing"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/4372"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/4372","href":"https://scholarscompass.vcu.edu/etd/4372","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/FYAG-KQ68","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/FYAG-KQ68","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-5430","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["John T. Beeston"]},{"key":"dc:creator","label":"Author","values":["Bowen, Danny R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2016-07-14T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1989-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Health Related Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nursing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/FYAG-KQ68","https://scholarscompass.vcu.edu/etd/4372"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A quasi-experimental research design was used to determine the relationship between the flow rate and the delivered temperature of prewarmed crystalloid intravenous solutions when using the Thermal Jacket™, an insulation device designed for intravenous fluid bags, as compared to a conventional blood warming apparatus. One control and three experimental groups were used. Fluids in Group 1 (control group), Group 2, and Group 4 were prewarmed in a microwave oven to 41.45 ± 1.05 ° C. Fluids in Group 3 were left near ambient room temperature and measured at 22.05 ± 0.45 ° C. Fluids in the control group were infused through a standard intravenous pump tubing, 270 em in length, using no temperature maintenance device. Fluids in Group 2 and Group 3 were delivered through a standard intravenous pump tubing connected to a blood warming coil which was immersed in a water bath blood warmer. The distance from the exit point of the blood warmer to the distal end of the infusion line measured 174 em. Fluids in Group 4 were placed in a Thermal Jacket™ and delivered through standard intravenous pump tubing. After a baseline measurement, temperatures were recorded for all groups at two sites at 10 minute intervals over a 60 minute period. One site was the lower portion of the IV solution bag, and the other site was a point 2 em from the distal end of the infusion set. Temperatures were measured at flow rates of 100, 250, 500, 750, and 1,000 ml/hr for each group. Analysis of variance showed a highly significant group effect on the delivered temperature. A Bonferroni multiple comparisons test indicated no statistically significant difference between the delivered temperatures of Group 3 (room temperature fluid + blood warmer) and Group 4 (prewarmed fluid + Thermal Jacket™). Group 2 (prewarmed fluid + blood warmer) showed a significantly higher delivered temperature (p < .05) than the other groups, and the control group (prewarmed + no temperature maintenance device) showed a significantly lower delivered temperature (12. < .05). Analysis of variance also showed a highly significant flow rate effect on delivered temperature. A Bonferroni multiple comparisons indicated a significant difference (12. < .05) between the flow rates of 100, 250, 500, and 750 ml/hr, with the higher flow rates resulting in higher delivered temperatures. There was no significant difference noted between the delivered temperatures at 750 and 1,000 ml/hr. The Thermal Jacket™, used with prewarmed intravenous fluids, was as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a higher delivered temperature."]},{"key":"dc:title","label":"Title","values":["Efficiency of the Thermal Jacket on the Delivered Temperature of Prewarmed Crystalloid Intravenous Fluid"]}]}],"canonical_facts":{"dc:contributor":["John T. Beeston"],"dc:creator":["Bowen, Danny R."],"dc:date.available":["2016-07-14T07:00:00Z"],"dc:date.created":["1989-01-01T08:00:00Z"],"dc:description.abstract":["A quasi-experimental research design was used to determine the relationship between the flow rate and the delivered temperature of prewarmed crystalloid intravenous solutions when using the Thermal Jacket™, an insulation device designed for intravenous fluid bags, as compared to a conventional blood warming apparatus. One control and three experimental groups were used. Fluids in Group 1 (control group), Group 2, and Group 4 were prewarmed in a microwave oven to 41.45 ± 1.05 ° C. Fluids in Group 3 were left near ambient room temperature and measured at 22.05 ± 0.45 ° C. Fluids in the control group were infused through a standard intravenous pump tubing, 270 em in length, using no temperature maintenance device. Fluids in Group 2 and Group 3 were delivered through a standard intravenous pump tubing connected to a blood warming coil which was immersed in a water bath blood warmer. The distance from the exit point of the blood warmer to the distal end of the infusion line measured 174 em. Fluids in Group 4 were placed in a Thermal Jacket™ and delivered through standard intravenous pump tubing. After a baseline measurement, temperatures were recorded for all groups at two sites at 10 minute intervals over a 60 minute period. One site was the lower portion of the IV solution bag, and the other site was a point 2 em from the distal end of the infusion set. Temperatures were measured at flow rates of 100, 250, 500, 750, and 1,000 ml/hr for each group. Analysis of variance showed a highly significant group effect on the delivered temperature. A Bonferroni multiple comparisons test indicated no statistically significant difference between the delivered temperatures of Group 3 (room temperature fluid + blood warmer) and Group 4 (prewarmed fluid + Thermal Jacket™). Group 2 (prewarmed fluid + blood warmer) showed a significantly higher delivered temperature (p < .05) than the other groups, and the control group (prewarmed + no temperature maintenance device) showed a significantly lower delivered temperature (12. < .05). Analysis of variance also showed a highly significant flow rate effect on delivered temperature. A Bonferroni multiple comparisons indicated a significant difference (12. < .05) between the flow rates of 100, 250, 500, and 750 ml/hr, with the higher flow rates resulting in higher delivered temperatures. There was no significant difference noted between the delivered temperatures at 750 and 1,000 ml/hr. The Thermal Jacket™, used with prewarmed intravenous fluids, was as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a higher delivered temperature."],"dc:identifier":["https://doi.org/10.25772/FYAG-KQ68","https://scholarscompass.vcu.edu/etd/4372"],"dc:rights":["© The Author"],"dc:subject":["Nursing"],"dc:title":["Efficiency of the Thermal Jacket on the Delivered Temperature of Prewarmed Crystalloid Intravenous Fluid"],"thesis:degree_discipline":["Health Related Sciences"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:11:33Z"}