{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-5985"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-5985","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation","abstract":"Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M™ True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax ™ bite registration yielded three of six acceptable inter-ach measurements. Conclusions: The iTero® and iTero® Element produced the most accurately articulated models. The 3M™ True Definition and Ortho Insight 3D® with Regisil® were the next most accurate. The Ortho Insight 3D® scanner with Coprwax ™ was the least accurate method tested.","abstract_html":"Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M™ True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax ™ bite registration yielded three of six acceptable inter-ach measurements. Conclusions: The iTero® and iTero® Element produced the most accurately articulated models. The 3M™ True Definition and Ortho Insight 3D® with Regisil® were the next most accurate. The Ortho Insight 3D® scanner with Coprwax ™ was the least accurate method tested.","abstract_has_math":false,"creators":["Porter, Jason L"],"institution":null,"degree_name":"Master of Science in Dentistry","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Eser Tüfekçi","Steven J. Lindauer","Caroline Carrico"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:12:10Z","subjects":["Digital Scanner","Orthodontics","Orthodontic Models","Orthodontic Records","Orthodontic Technology","Orthodontics and Orthodontology"],"languages":[],"rights":["© Jason Porter"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/4881"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/4881","href":"https://scholarscompass.vcu.edu/etd/4881","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/MGKE-8P85","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/MGKE-8P85","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-5985","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Eser Tüfekçi","Steven J. Lindauer","Caroline Carrico"]},{"key":"dc:creator","label":"Author","values":["Porter, Jason L"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-05-17T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Digital Scanner","Orthodontics","Orthodontic Models","Orthodontic Records","Orthodontic Technology","Orthodontics and Orthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© Jason Porter"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/MGKE-8P85","https://scholarscompass.vcu.edu/etd/4881"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M™ True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax ™ bite registration yielded three of six acceptable inter-ach measurements. Conclusions: The iTero® and iTero® Element produced the most accurately articulated models. The 3M™ True Definition and Ortho Insight 3D® with Regisil® were the next most accurate. The Ortho Insight 3D® scanner with Coprwax ™ was the least accurate method tested."]},{"key":"dc:title","label":"Title","values":["Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation"]}]}],"canonical_facts":{"dc:contributor":["Eser Tüfekçi","Steven J. Lindauer","Caroline Carrico"],"dc:creator":["Porter, Jason L"],"dc:date.available":["2017-05-17T07:00:00Z"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M™ True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax ™ bite registration yielded three of six acceptable inter-ach measurements. Conclusions: The iTero® and iTero® Element produced the most accurately articulated models. The 3M™ True Definition and Ortho Insight 3D® with Regisil® were the next most accurate. The Ortho Insight 3D® scanner with Coprwax ™ was the least accurate method tested."],"dc:identifier":["https://doi.org/10.25772/MGKE-8P85","https://scholarscompass.vcu.edu/etd/4881"],"dc:rights":["© Jason Porter"],"dc:subject":["Digital Scanner","Orthodontics","Orthodontic Models","Orthodontic Records","Orthodontic Technology","Orthodontics and Orthodontology"],"dc:title":["Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Dentistry"]},"updated_at":"2026-11-19T09:12:10Z"}