{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-6627"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-6627","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Motion-Induced Artifact Mitigation and Image Enhancement Strategies for Four-Dimensional Fan-Beam and Cone-Beam Computed Tomography","abstract":"Four dimensional imaging has become part of the standard of care for diagnosing and treating non-small cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and provide insight into the effects of regular organ motion and the nature of tissue deformation over time. While these imaging techniques can facilitate the use of more targeted radiotherapies, issues surrounding image quality and accuracy currently limit the utility of these images clinically. The purpose of this project is to develop methods that retrospectively compensate for anatomical motion in 4D-CBCT and correct motion artifacts present in 4D-CT to improve the image quality of reconstructed volume and assist in localizing respiration-influenced, diseased tissue and mobile structures of interest. In the first half of the project, a series of motion compensation (MoCo) workflow methods incorporating groupwise deformable image registration and projection-warped reconstruction were developed for use with 4D-CBCT imaging. In the latter half of the project, novel motion artifact observation and artifact- weighted groupwise registration-based image correction algorithms were designed and tested. Both deliverable components of this project were evaluated for their ability to enhance image quality when applied to clinical patient datasets and demonstrated qualitative and quantitative improvements over current state-of-the-art.","abstract_html":"Four dimensional imaging has become part of the standard of care for diagnosing and treating non-small cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and provide insight into the effects of regular organ motion and the nature of tissue deformation over time. While these imaging techniques can facilitate the use of more targeted radiotherapies, issues surrounding image quality and accuracy currently limit the utility of these images clinically. The purpose of this project is to develop methods that retrospectively compensate for anatomical motion in 4D-CBCT and correct motion artifacts present in 4D-CT to improve the image quality of reconstructed volume and assist in localizing respiration-influenced, diseased tissue and mobile structures of interest. In the first half of the project, a series of motion compensation (MoCo) workflow methods incorporating groupwise deformable image registration and projection-warped reconstruction were developed for use with 4D-CBCT imaging. In the latter half of the project, novel motion artifact observation and artifact- weighted groupwise registration-based image correction algorithms were designed and tested. Both deliverable components of this project were evaluated for their ability to enhance image quality when applied to clinical patient datasets and demonstrated qualitative and quantitative improvements over current state-of-the-art.","abstract_has_math":false,"creators":["Riblett, Matthew J","https://orcid.org/0000-0003-1049-1774"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"Dissertation","degree_discipline":"Medical Physics","degree_department":null,"school":null,"contributors":["Elisabeth Weiss","Geoffrey D. Hugo","Gary E. Christensen","Laura Padilla","Milos Manic"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:13:04Z","subjects":["lung cancer","computed tomography","cone-beam","motion compensation","machine learning","convolutional neural networks","Investigative Techniques","Oncology","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Physics","Radiology"],"languages":[],"rights":["© Matthew J. Riblett"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/5542"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/5542","href":"https://scholarscompass.vcu.edu/etd/5542","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/TA2C-6Y94","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/TA2C-6Y94","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-6627","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Elisabeth Weiss","Geoffrey D. Hugo","Gary E. Christensen","Laura Padilla","Milos Manic"]},{"key":"dc:creator","label":"Author","values":["Riblett, Matthew J","https://orcid.org/0000-0003-1049-1774"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["lung cancer","computed tomography","cone-beam","motion compensation","machine learning","convolutional neural networks","Investigative Techniques","Oncology","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Physics","Radiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© Matthew J. Riblett"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/TA2C-6Y94","https://scholarscompass.vcu.edu/etd/5542"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Four dimensional imaging has become part of the standard of care for diagnosing and treating non-small cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and provide insight into the effects of regular organ motion and the nature of tissue deformation over time. While these imaging techniques can facilitate the use of more targeted radiotherapies, issues surrounding image quality and accuracy currently limit the utility of these images clinically. The purpose of this project is to develop methods that retrospectively compensate for anatomical motion in 4D-CBCT and correct motion artifacts present in 4D-CT to improve the image quality of reconstructed volume and assist in localizing respiration-influenced, diseased tissue and mobile structures of interest. In the first half of the project, a series of motion compensation (MoCo) workflow methods incorporating groupwise deformable image registration and projection-warped reconstruction were developed for use with 4D-CBCT imaging. In the latter half of the project, novel motion artifact observation and artifact- weighted groupwise registration-based image correction algorithms were designed and tested. Both deliverable components of this project were evaluated for their ability to enhance image quality when applied to clinical patient datasets and demonstrated qualitative and quantitative improvements over current state-of-the-art."]},{"key":"dc:title","label":"Title","values":["Motion-Induced Artifact Mitigation and Image Enhancement Strategies for Four-Dimensional Fan-Beam and Cone-Beam Computed Tomography"]}]}],"canonical_facts":{"dc:contributor":["Elisabeth Weiss","Geoffrey D. Hugo","Gary E. Christensen","Laura Padilla","Milos Manic"],"dc:creator":["Riblett, Matthew J","https://orcid.org/0000-0003-1049-1774"],"dc:date.available":["2019-07-09T07:00:00Z"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["Four dimensional imaging has become part of the standard of care for diagnosing and treating non-small cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and provide insight into the effects of regular organ motion and the nature of tissue deformation over time. While these imaging techniques can facilitate the use of more targeted radiotherapies, issues surrounding image quality and accuracy currently limit the utility of these images clinically. The purpose of this project is to develop methods that retrospectively compensate for anatomical motion in 4D-CBCT and correct motion artifacts present in 4D-CT to improve the image quality of reconstructed volume and assist in localizing respiration-influenced, diseased tissue and mobile structures of interest. In the first half of the project, a series of motion compensation (MoCo) workflow methods incorporating groupwise deformable image registration and projection-warped reconstruction were developed for use with 4D-CBCT imaging. In the latter half of the project, novel motion artifact observation and artifact- weighted groupwise registration-based image correction algorithms were designed and tested. Both deliverable components of this project were evaluated for their ability to enhance image quality when applied to clinical patient datasets and demonstrated qualitative and quantitative improvements over current state-of-the-art."],"dc:identifier":["https://doi.org/10.25772/TA2C-6Y94","https://scholarscompass.vcu.edu/etd/5542"],"dc:rights":["© Matthew J. Riblett"],"dc:subject":["lung cancer","computed tomography","cone-beam","motion compensation","machine learning","convolutional neural networks","Investigative Techniques","Oncology","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Physics","Radiology"],"dc:title":["Motion-Induced Artifact Mitigation and Image Enhancement Strategies for Four-Dimensional Fan-Beam and Cone-Beam Computed Tomography"],"thesis:degree_discipline":["Medical Physics"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-11-19T09:13:04Z"}