{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-6858"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-6858","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"FRICTIONAL PROPERTIES OF NOVEL BRACKET SYSTEMS: AN IN-VITRO STUDY","abstract":"Orthodontic brackets undergo resistance during sliding that includes classical friction, binding, and notching. Current bracket systems are hampered by these challenging forces. As a result, the clinician usually needs to apply additional forces to overcome the resistance which increases the risk of root resorption and discomfort for the patient. This study evaluated frictional properties of a novel bracket that had polytetrafluoroethylene (Teflon™) coated rollers in its design. Five types of brackets (n = 10, each), including a passive self-ligating bracket, a traditional ligated bracket, a three-dimensionally printed direct metal laser sintering (DMLS) bracket with and without Teflon™ rollers, and computer numeric controlled (CNC) machine milled bracket with Teflon™ rollers were tested. The peak resistance values were assessed at 0°, 4°, and 8° of tip on a 0.019 x 0.025” arch wire. At 8° of tip, the DMLS and the CNC milled bracket systems, both with Teflon™ rollers, exhibited less friction as compared to the other brackets tested (p","abstract_html":"Orthodontic brackets undergo resistance during sliding that includes classical friction, binding, and notching. Current bracket systems are hampered by these challenging forces. As a result, the clinician usually needs to apply additional forces to overcome the resistance which increases the risk of root resorption and discomfort for the patient. This study evaluated frictional properties of a novel bracket that had polytetrafluoroethylene (Teflon™) coated rollers in its design. Five types of brackets (n = 10, each), including a passive self-ligating bracket, a traditional ligated bracket, a three-dimensionally printed direct metal laser sintering (DMLS) bracket with and without Teflon™ rollers, and computer numeric controlled (CNC) machine milled bracket with Teflon™ rollers were tested. The peak resistance values were assessed at 0°, 4°, and 8° of tip on a 0.019 x 0.025” arch wire. At 8° of tip, the DMLS and the CNC milled bracket systems, both with Teflon™ rollers, exhibited less friction as compared to the other brackets tested (p","abstract_has_math":false,"creators":["Haverkos, Stephen M"],"institution":null,"degree_name":"Master of Science in Dentistry","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Dr. Eser Tufekci"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:13:19Z","subjects":["Teflon","Friction","Bracket Sliding","Direct Metal Laser Sintering","3D Printed Bracket","Rollers","Orthodontics and Orthodontology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/5770"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/5770","href":"https://scholarscompass.vcu.edu/etd/5770","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/9F95-AJ96","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/9F95-AJ96","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-6858","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Eser Tufekci"]},{"key":"dc:creator","label":"Author","values":["Haverkos, Stephen M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-04-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Teflon","Friction","Bracket Sliding","Direct Metal Laser Sintering","3D Printed Bracket","Rollers","Orthodontics and Orthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/9F95-AJ96","https://scholarscompass.vcu.edu/etd/5770"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Orthodontic brackets undergo resistance during sliding that includes classical friction, binding, and notching. Current bracket systems are hampered by these challenging forces. As a result, the clinician usually needs to apply additional forces to overcome the resistance which increases the risk of root resorption and discomfort for the patient. This study evaluated frictional properties of a novel bracket that had polytetrafluoroethylene (Teflon™) coated rollers in its design. Five types of brackets (n = 10, each), including a passive self-ligating bracket, a traditional ligated bracket, a three-dimensionally printed direct metal laser sintering (DMLS) bracket with and without Teflon™ rollers, and computer numeric controlled (CNC) machine milled bracket with Teflon™ rollers were tested. The peak resistance values were assessed at 0°, 4°, and 8° of tip on a 0.019 x 0.025” arch wire. At 8° of tip, the DMLS and the CNC milled bracket systems, both with Teflon™ rollers, exhibited less friction as compared to the other brackets tested (p"]},{"key":"dc:title","label":"Title","values":["FRICTIONAL PROPERTIES OF NOVEL BRACKET SYSTEMS: AN IN-VITRO STUDY"]}]}],"canonical_facts":{"dc:contributor":["Dr. Eser Tufekci"],"dc:creator":["Haverkos, Stephen M"],"dc:date.available":["2020-04-29T07:00:00Z"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["Orthodontic brackets undergo resistance during sliding that includes classical friction, binding, and notching. Current bracket systems are hampered by these challenging forces. As a result, the clinician usually needs to apply additional forces to overcome the resistance which increases the risk of root resorption and discomfort for the patient. This study evaluated frictional properties of a novel bracket that had polytetrafluoroethylene (Teflon™) coated rollers in its design. Five types of brackets (n = 10, each), including a passive self-ligating bracket, a traditional ligated bracket, a three-dimensionally printed direct metal laser sintering (DMLS) bracket with and without Teflon™ rollers, and computer numeric controlled (CNC) machine milled bracket with Teflon™ rollers were tested. The peak resistance values were assessed at 0°, 4°, and 8° of tip on a 0.019 x 0.025” arch wire. At 8° of tip, the DMLS and the CNC milled bracket systems, both with Teflon™ rollers, exhibited less friction as compared to the other brackets tested (p"],"dc:identifier":["https://doi.org/10.25772/9F95-AJ96","https://scholarscompass.vcu.edu/etd/5770"],"dc:rights":["© The Author"],"dc:subject":["Teflon","Friction","Bracket Sliding","Direct Metal Laser Sintering","3D Printed Bracket","Rollers","Orthodontics and Orthodontology"],"dc:title":["FRICTIONAL PROPERTIES OF NOVEL BRACKET SYSTEMS: AN IN-VITRO STUDY"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Dentistry"]},"updated_at":"2026-11-19T09:13:19Z"}