{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-7277"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-7277","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"EXPLORING THE USE OF PULSED ERBIUM LASERS TO RETRIEVE A ZIRCONIA CROWN FROM A ZIRCONIA IMPLANT ABUTMENT","abstract":"Removal of zirconia crowns, commonly used as cement-retained implant fixed restorations, can be challenging. Conventional methods of crown removal are time consuming and often leave irreparable damage to the crown, which can be costly to patients and practitioners. This research explored the use of two different types of pulsed erbium lasers, erbium-doped yttrium aluminum garnet laser (Er:YAG) and erbium, chromium-doped yttrium, scandium, gallium and garnet (Er,Cr:YSGG), as non-invasive tools to retrieve cemented zirconia crowns from zirconia implant abutments. Times needed to remove the crowns were recorded and analyzed using ANOVA (��=0.05). No statistical differences between the debond times of each laser were observed. The surfaces of the crown and the abutment were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) examination. SEM and EDS examinations of the materials showed no visual surface damaging or material alteration from the two pulsed erbium lasers.","abstract_html":"Removal of zirconia crowns, commonly used as cement-retained implant fixed restorations, can be challenging. Conventional methods of crown removal are time consuming and often leave irreparable damage to the crown, which can be costly to patients and practitioners. This research explored the use of two different types of pulsed erbium lasers, erbium-doped yttrium aluminum garnet laser (Er:YAG) and erbium, chromium-doped yttrium, scandium, gallium and garnet (Er,Cr:YSGG), as non-invasive tools to retrieve cemented zirconia crowns from zirconia implant abutments. Times needed to remove the crowns were recorded and analyzed using ANOVA (��=0.05). No statistical differences between the debond times of each laser were observed. The surfaces of the crown and the abutment were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) examination. SEM and EDS examinations of the materials showed no visual surface damaging or material alteration from the two pulsed erbium lasers.","abstract_has_math":false,"creators":["Elkharashi, Ahmed"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biochemistry","degree_department":null,"school":null,"contributors":["Sompop Bencharit"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:13:47Z","subjects":["Crown Removal","Dental Lasers","Er:YAG","Er","Cr:YSGG","Zirconia Crowns","Zirconia Abutments","Dental Materials","Dentistry","Prosthodontics and Prosthodontology"],"languages":[],"rights":["© Ahmed Elkharashi"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/6146"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/6146","href":"https://scholarscompass.vcu.edu/etd/6146","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/8Z6S-PM92","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/8Z6S-PM92","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-7277","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sompop Bencharit"]},{"key":"dc:creator","label":"Author","values":["Elkharashi, Ahmed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-04-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biochemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Crown Removal","Dental Lasers","Er:YAG","Er","Cr:YSGG","Zirconia Crowns","Zirconia Abutments","Dental Materials","Dentistry","Prosthodontics and Prosthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© Ahmed Elkharashi"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/8Z6S-PM92","https://scholarscompass.vcu.edu/etd/6146"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Removal of zirconia crowns, commonly used as cement-retained implant fixed restorations, can be challenging. Conventional methods of crown removal are time consuming and often leave irreparable damage to the crown, which can be costly to patients and practitioners. This research explored the use of two different types of pulsed erbium lasers, erbium-doped yttrium aluminum garnet laser (Er:YAG) and erbium, chromium-doped yttrium, scandium, gallium and garnet (Er,Cr:YSGG), as non-invasive tools to retrieve cemented zirconia crowns from zirconia implant abutments. Times needed to remove the crowns were recorded and analyzed using ANOVA (��=0.05). No statistical differences between the debond times of each laser were observed. The surfaces of the crown and the abutment were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) examination. SEM and EDS examinations of the materials showed no visual surface damaging or material alteration from the two pulsed erbium lasers."]},{"key":"dc:title","label":"Title","values":["EXPLORING THE USE OF PULSED ERBIUM LASERS TO RETRIEVE A ZIRCONIA CROWN FROM A ZIRCONIA IMPLANT ABUTMENT"]}]}],"canonical_facts":{"dc:contributor":["Sompop Bencharit"],"dc:creator":["Elkharashi, Ahmed"],"dc:date.available":["2020-04-30T07:00:00Z"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["Removal of zirconia crowns, commonly used as cement-retained implant fixed restorations, can be challenging. Conventional methods of crown removal are time consuming and often leave irreparable damage to the crown, which can be costly to patients and practitioners. This research explored the use of two different types of pulsed erbium lasers, erbium-doped yttrium aluminum garnet laser (Er:YAG) and erbium, chromium-doped yttrium, scandium, gallium and garnet (Er,Cr:YSGG), as non-invasive tools to retrieve cemented zirconia crowns from zirconia implant abutments. Times needed to remove the crowns were recorded and analyzed using ANOVA (��=0.05). No statistical differences between the debond times of each laser were observed. The surfaces of the crown and the abutment were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) examination. SEM and EDS examinations of the materials showed no visual surface damaging or material alteration from the two pulsed erbium lasers."],"dc:identifier":["https://doi.org/10.25772/8Z6S-PM92","https://scholarscompass.vcu.edu/etd/6146"],"dc:rights":["© Ahmed Elkharashi"],"dc:subject":["Crown Removal","Dental Lasers","Er:YAG","Er","Cr:YSGG","Zirconia Crowns","Zirconia Abutments","Dental Materials","Dentistry","Prosthodontics and Prosthodontology"],"dc:title":["EXPLORING THE USE OF PULSED ERBIUM LASERS TO RETRIEVE A ZIRCONIA CROWN FROM A ZIRCONIA IMPLANT ABUTMENT"],"thesis:degree_discipline":["Biochemistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:13:47Z"}