{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-7734"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-7734","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Reproducibility and accuracy of the virtual occlusal record","abstract":"Purpose: To evaluate the reproducibility and accuracy of the virtual occlusal record compared to the gold standard physical bite record Methods: Two physical bite records of PVS and two virtual bites using an iTero Element scanner were obtained from 22 participants. Intraoral scans were exported as STL files, and virtual occlusal records were created. CBCT images were taken of physical occlusal records and converted to STL files. STL files were superimposed using Geomagic Control X™ Software. Root mean square (RMS) and percent similarity within 0.25 mm tolerance were compared at a significance level of 0.05. Results: Average RMS between physical records was 0.34, which was significantly higher than repeat virtual bite comparisons (p<0.0001), with an average percent within tolerance of 76.33%, which was significantly lower than repeat virtual bite comparisons (p<0.0001). Average RMS between repeated virtual records was 0.12 with an average percent within tolerance of 97.84%. Average RMS between physical and virtual records was 0.61, which was significantly higher than both repeat comparisons for physical and virtual records (p<0.0001), with an average percent within tolerance of 50.88%, which was significantly lower than both repeat comparisons for physical and virtual records (p<0.0001). Conclusion: Virtual occlusal records are significantly more reproducible than physical occlusal records. Statistically and clinically significant differences exist between virtual and physical records. Some of the differences could have been due to variations in the physical bite records themselves. Virtual occlusal records may be more accurate than physical bite records, but additional research is needed to confirm this.","abstract_html":"Purpose: To evaluate the reproducibility and accuracy of the virtual occlusal record compared to the gold standard physical bite record Methods: Two physical bite records of PVS and two virtual bites using an iTero Element scanner were obtained from 22 participants. Intraoral scans were exported as STL files, and virtual occlusal records were created. CBCT images were taken of physical occlusal records and converted to STL files. STL files were superimposed using Geomagic Control X™ Software. Root mean square (RMS) and percent similarity within 0.25 mm tolerance were compared at a significance level of 0.05. Results: Average RMS between physical records was 0.34, which was significantly higher than repeat virtual bite comparisons (p&lt;0.0001), with an average percent within tolerance of 76.33%, which was significantly lower than repeat virtual bite comparisons (p&lt;0.0001). Average RMS between repeated virtual records was 0.12 with an average percent within tolerance of 97.84%. Average RMS between physical and virtual records was 0.61, which was significantly higher than both repeat comparisons for physical and virtual records (p&lt;0.0001), with an average percent within tolerance of 50.88%, which was significantly lower than both repeat comparisons for physical and virtual records (p&lt;0.0001). Conclusion: Virtual occlusal records are significantly more reproducible than physical occlusal records. Statistically and clinically significant differences exist between virtual and physical records. Some of the differences could have been due to variations in the physical bite records themselves. Virtual occlusal records may be more accurate than physical bite records, but additional research is needed to confirm this.","abstract_has_math":false,"creators":["Harper, Anne M","<p>https://orcid.org/0000-0002-6268-9398</p>"],"institution":null,"degree_name":"Master of Science in Dentistry","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Steven Lindauer","Bhavna Shroff","Caroline Carrico"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:14:28Z","subjects":["occlusal record","virtual occlusal record","virtual record","intraoral scanning","bite record","accuracy","Orthodontics and Orthodontology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/6579"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/6579","href":"https://scholarscompass.vcu.edu/etd/6579","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/KHKR-W661","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/KHKR-W661","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-7734","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Steven Lindauer","Bhavna Shroff","Caroline Carrico"]},{"key":"dc:creator","label":"Author","values":["Harper, Anne M","<p>https://orcid.org/0000-0002-6268-9398</p>"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-05-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["occlusal record","virtual occlusal record","virtual record","intraoral scanning","bite record","accuracy","Orthodontics and Orthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/KHKR-W661","https://scholarscompass.vcu.edu/etd/6579"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: To evaluate the reproducibility and accuracy of the virtual occlusal record compared to the gold standard physical bite record Methods: Two physical bite records of PVS and two virtual bites using an iTero Element scanner were obtained from 22 participants. Intraoral scans were exported as STL files, and virtual occlusal records were created. CBCT images were taken of physical occlusal records and converted to STL files. STL files were superimposed using Geomagic Control X™ Software. Root mean square (RMS) and percent similarity within 0.25 mm tolerance were compared at a significance level of 0.05. Results: Average RMS between physical records was 0.34, which was significantly higher than repeat virtual bite comparisons (p<0.0001), with an average percent within tolerance of 76.33%, which was significantly lower than repeat virtual bite comparisons (p<0.0001). Average RMS between repeated virtual records was 0.12 with an average percent within tolerance of 97.84%. Average RMS between physical and virtual records was 0.61, which was significantly higher than both repeat comparisons for physical and virtual records (p<0.0001), with an average percent within tolerance of 50.88%, which was significantly lower than both repeat comparisons for physical and virtual records (p<0.0001). Conclusion: Virtual occlusal records are significantly more reproducible than physical occlusal records. Statistically and clinically significant differences exist between virtual and physical records. Some of the differences could have been due to variations in the physical bite records themselves. Virtual occlusal records may be more accurate than physical bite records, but additional research is needed to confirm this."]},{"key":"dc:title","label":"Title","values":["Reproducibility and accuracy of the virtual occlusal record"]}]}],"canonical_facts":{"dc:contributor":["Steven Lindauer","Bhavna Shroff","Caroline Carrico"],"dc:creator":["Harper, Anne M","<p>https://orcid.org/0000-0002-6268-9398</p>"],"dc:date.available":["2022-05-10T07:00:00Z"],"dc:date.created":["2021-01-01T08:00:00Z"],"dc:description.abstract":["Purpose: To evaluate the reproducibility and accuracy of the virtual occlusal record compared to the gold standard physical bite record Methods: Two physical bite records of PVS and two virtual bites using an iTero Element scanner were obtained from 22 participants. Intraoral scans were exported as STL files, and virtual occlusal records were created. CBCT images were taken of physical occlusal records and converted to STL files. STL files were superimposed using Geomagic Control X™ Software. Root mean square (RMS) and percent similarity within 0.25 mm tolerance were compared at a significance level of 0.05. Results: Average RMS between physical records was 0.34, which was significantly higher than repeat virtual bite comparisons (p<0.0001), with an average percent within tolerance of 76.33%, which was significantly lower than repeat virtual bite comparisons (p<0.0001). Average RMS between repeated virtual records was 0.12 with an average percent within tolerance of 97.84%. Average RMS between physical and virtual records was 0.61, which was significantly higher than both repeat comparisons for physical and virtual records (p<0.0001), with an average percent within tolerance of 50.88%, which was significantly lower than both repeat comparisons for physical and virtual records (p<0.0001). Conclusion: Virtual occlusal records are significantly more reproducible than physical occlusal records. Statistically and clinically significant differences exist between virtual and physical records. Some of the differences could have been due to variations in the physical bite records themselves. Virtual occlusal records may be more accurate than physical bite records, but additional research is needed to confirm this."],"dc:identifier":["https://doi.org/10.25772/KHKR-W661","https://scholarscompass.vcu.edu/etd/6579"],"dc:rights":["© The Author"],"dc:subject":["occlusal record","virtual occlusal record","virtual record","intraoral scanning","bite record","accuracy","Orthodontics and Orthodontology"],"dc:title":["Reproducibility and accuracy of the virtual occlusal record"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Dentistry"]},"updated_at":"2026-11-19T09:14:28Z"}