{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-8239"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-8239","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Improving the Early Detection of Cardiovascular Toxicity Secondary to Radiotherapy for Lung Cancer via Patient-specific Quantitative Magnetic Resonance Imaging","abstract":"Purpose: To assess the cardiopulmonary-induced dose variation on the left ventricle (LV) and evaluate the spatiotemporal evolution of cardiac/aortic function following radiotherapy (RT). Methods: 8 lung cancer patients who were scheduled to receive RT were recruited for this study. Each patient underwent one 4D-CT at baseline. MRI scans including cine GRE, T1/T2, LGE, and 4D-flow were acquired at baseline, 3-months and 6-months post-RT to evaluate the cardiac/aortic function. Finally, image registration was used to assess the cardiopulmonary-induced dose variation on the LV. Results: Mean RT-dose was minimum during inspiration and systole (at expiration). No significant differences were found in the maximum dose during cardiac/respiratory motion. Finally, higher mean segmental cumulative doses were estimated at regions closer to the tumor location. In regards to RT-induced cardiac/aortic toxicity, global metrics did not show any significant changes post-RT except for T2/LGE. Though, regional metrics showed significant changes over at least one follow-up with a dose-dependency response among radiobiological metrics. A correlation was observed between T1 and T2 signal, and between aortic dose and radial/circumferential strain drop at basal anteroseptal of the LV at 6-months post-RT completion. Conclusion: To minimize the LV RT-dose, it is recommended to deliver the radiation during inspiration and systole. Radiobiological metrics precede mechanical changes in evaluation of RT-induced toxicity with a dose-dependency response over higher doses (>50 Gy). Myocardial fibrosis may induce edema or vice versa given the T1/T2 signal correlation at 6-months. Finally, aortic dose may indirectly damage LV function where LV and aorta are in mechanical continuity.","abstract_html":"Purpose: To assess the cardiopulmonary-induced dose variation on the left ventricle (LV) and evaluate the spatiotemporal evolution of cardiac/aortic function following radiotherapy (RT). Methods: 8 lung cancer patients who were scheduled to receive RT were recruited for this study. Each patient underwent one 4D-CT at baseline. MRI scans including cine GRE, T1/T2, LGE, and 4D-flow were acquired at baseline, 3-months and 6-months post-RT to evaluate the cardiac/aortic function. Finally, image registration was used to assess the cardiopulmonary-induced dose variation on the LV. Results: Mean RT-dose was minimum during inspiration and systole (at expiration). No significant differences were found in the maximum dose during cardiac/respiratory motion. Finally, higher mean segmental cumulative doses were estimated at regions closer to the tumor location. In regards to RT-induced cardiac/aortic toxicity, global metrics did not show any significant changes post-RT except for T2/LGE. Though, regional metrics showed significant changes over at least one follow-up with a dose-dependency response among radiobiological metrics. A correlation was observed between T1 and T2 signal, and between aortic dose and radial/circumferential strain drop at basal anteroseptal of the LV at 6-months post-RT completion. Conclusion: To minimize the LV RT-dose, it is recommended to deliver the radiation during inspiration and systole. Radiobiological metrics precede mechanical changes in evaluation of RT-induced toxicity with a dose-dependency response over higher doses (&gt;50 Gy). Myocardial fibrosis may induce edema or vice versa given the T1/T2 signal correlation at 6-months. Finally, aortic dose may indirectly damage LV function where LV and aorta are in mechanical continuity.","abstract_has_math":false,"creators":["Omidi, Alireza","https://orcid.org/0000-0003-3407-2160"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"Dissertation","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Dr. John S. Wilson"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:15:03Z","subjects":["Cardiovascular toxicity","radiotherapy","magnetic resonance imaging","image registration","Biomechanics and Biotransport","Other Biomedical Engineering and Bioengineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/7100"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/7100","href":"https://scholarscompass.vcu.edu/etd/7100","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/M9Q0-A726","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/M9Q0-A726","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-8239","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. John S. Wilson"]},{"key":"dc:creator","label":"Author","values":["Omidi, Alireza","https://orcid.org/0000-0003-3407-2160"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cardiovascular toxicity","radiotherapy","magnetic resonance imaging","image registration","Biomechanics and Biotransport","Other Biomedical Engineering and Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/M9Q0-A726","https://scholarscompass.vcu.edu/etd/7100"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: To assess the cardiopulmonary-induced dose variation on the left ventricle (LV) and evaluate the spatiotemporal evolution of cardiac/aortic function following radiotherapy (RT). Methods: 8 lung cancer patients who were scheduled to receive RT were recruited for this study. Each patient underwent one 4D-CT at baseline. MRI scans including cine GRE, T1/T2, LGE, and 4D-flow were acquired at baseline, 3-months and 6-months post-RT to evaluate the cardiac/aortic function. Finally, image registration was used to assess the cardiopulmonary-induced dose variation on the LV. Results: Mean RT-dose was minimum during inspiration and systole (at expiration). No significant differences were found in the maximum dose during cardiac/respiratory motion. Finally, higher mean segmental cumulative doses were estimated at regions closer to the tumor location. In regards to RT-induced cardiac/aortic toxicity, global metrics did not show any significant changes post-RT except for T2/LGE. Though, regional metrics showed significant changes over at least one follow-up with a dose-dependency response among radiobiological metrics. A correlation was observed between T1 and T2 signal, and between aortic dose and radial/circumferential strain drop at basal anteroseptal of the LV at 6-months post-RT completion. Conclusion: To minimize the LV RT-dose, it is recommended to deliver the radiation during inspiration and systole. Radiobiological metrics precede mechanical changes in evaluation of RT-induced toxicity with a dose-dependency response over higher doses (>50 Gy). Myocardial fibrosis may induce edema or vice versa given the T1/T2 signal correlation at 6-months. Finally, aortic dose may indirectly damage LV function where LV and aorta are in mechanical continuity."]},{"key":"dc:title","label":"Title","values":["Improving the Early Detection of Cardiovascular Toxicity Secondary to Radiotherapy for Lung Cancer via Patient-specific Quantitative Magnetic Resonance Imaging"]}]}],"canonical_facts":{"dc:contributor":["Dr. John S. Wilson"],"dc:creator":["Omidi, Alireza","https://orcid.org/0000-0003-3407-2160"],"dc:date.available":["2023-08-10T07:00:00Z"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["Purpose: To assess the cardiopulmonary-induced dose variation on the left ventricle (LV) and evaluate the spatiotemporal evolution of cardiac/aortic function following radiotherapy (RT). Methods: 8 lung cancer patients who were scheduled to receive RT were recruited for this study. Each patient underwent one 4D-CT at baseline. MRI scans including cine GRE, T1/T2, LGE, and 4D-flow were acquired at baseline, 3-months and 6-months post-RT to evaluate the cardiac/aortic function. Finally, image registration was used to assess the cardiopulmonary-induced dose variation on the LV. Results: Mean RT-dose was minimum during inspiration and systole (at expiration). No significant differences were found in the maximum dose during cardiac/respiratory motion. Finally, higher mean segmental cumulative doses were estimated at regions closer to the tumor location. In regards to RT-induced cardiac/aortic toxicity, global metrics did not show any significant changes post-RT except for T2/LGE. Though, regional metrics showed significant changes over at least one follow-up with a dose-dependency response among radiobiological metrics. A correlation was observed between T1 and T2 signal, and between aortic dose and radial/circumferential strain drop at basal anteroseptal of the LV at 6-months post-RT completion. Conclusion: To minimize the LV RT-dose, it is recommended to deliver the radiation during inspiration and systole. Radiobiological metrics precede mechanical changes in evaluation of RT-induced toxicity with a dose-dependency response over higher doses (>50 Gy). Myocardial fibrosis may induce edema or vice versa given the T1/T2 signal correlation at 6-months. Finally, aortic dose may indirectly damage LV function where LV and aorta are in mechanical continuity."],"dc:identifier":["https://doi.org/10.25772/M9Q0-A726","https://scholarscompass.vcu.edu/etd/7100"],"dc:rights":["© The Author"],"dc:subject":["Cardiovascular toxicity","radiotherapy","magnetic resonance imaging","image registration","Biomechanics and Biotransport","Other Biomedical Engineering and Bioengineering"],"dc:title":["Improving the Early Detection of Cardiovascular Toxicity Secondary to Radiotherapy for Lung Cancer via Patient-specific Quantitative Magnetic Resonance Imaging"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-11-19T09:15:03Z"}