{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-9407"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-9407","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Low-Cost Temperature Monitoring and Control for Microwave Solid Reactor","abstract":"<p>A low-cost and fully controllable microwave reactor was developed using accessible and commercially available equipment for use in laboratory scale solid state chemistry. The design used a magnetron as the source of electromagnetic radiation to heat the sample. A domestic microwave cavity was repurposed as the resonance chamber to ensure safe confinement of electromagnetic radiation while providing a sufficiently large volume for solid samples and reaction vessels. The power delivery to the magnetron was modulated by an inverter circuit with sufficiently high response time to be controlled with a PWM signal from a microcontroller. An IR sensor was implemented to both monitor and provide a signal for a feedback control loop. Paired with the rapid power modulation of the inverter circuit, heating rate and temperature can be controlled allowing for reliable chemical processing in a wide range of temperatures. To allow for facile control and monitoring of chemical processes in real time, a user interface was implemented to change important process parameters, monitor temperature and power use, and store data from runs for further analysis. To ensure longevity of the reactor, a cooling loop was implemented to cool the magnetron from overheating. The performance was demonstrated using a dehydration reaction of nickel oxalate dihydrate in anhydrous nickel oxalate. Results demonstrate reliable heating of samples for kinetic analysis. Overall, this work provides an accessible and modular platform of a microwave reactor that has applications in kinetic reaction analysis and intensification of solid-state chemical processing.</p>","abstract_html":"&lt;p&gt;A low-cost and fully controllable microwave reactor was developed using accessible and commercially available equipment for use in laboratory scale solid state chemistry. The design used a magnetron as the source of electromagnetic radiation to heat the sample. A domestic microwave cavity was repurposed as the resonance chamber to ensure safe confinement of electromagnetic radiation while providing a sufficiently large volume for solid samples and reaction vessels. The power delivery to the magnetron was modulated by an inverter circuit with sufficiently high response time to be controlled with a PWM signal from a microcontroller. An IR sensor was implemented to both monitor and provide a signal for a feedback control loop. Paired with the rapid power modulation of the inverter circuit, heating rate and temperature can be controlled allowing for reliable chemical processing in a wide range of temperatures. To allow for facile control and monitoring of chemical processes in real time, a user interface was implemented to change important process parameters, monitor temperature and power use, and store data from runs for further analysis. To ensure longevity of the reactor, a cooling loop was implemented to cool the magnetron from overheating. The performance was demonstrated using a dehydration reaction of nickel oxalate dihydrate in anhydrous nickel oxalate. Results demonstrate reliable heating of samples for kinetic analysis. Overall, this work provides an accessible and modular platform of a microwave reactor that has applications in kinetic reaction analysis and intensification of solid-state chemical processing.&lt;/p&gt;","abstract_has_math":false,"creators":["Miller, Carter M"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Chemical and Life Science Engineering","degree_department":null,"school":null,"contributors":["Mo Jiang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-01-01T08:00:00Z","date_published":"2025-01-01T08:00:00Z","updated_at":"2026-11-27T10:08:55Z","subjects":["Process Control and Systems"],"languages":[],"rights":["© Carter Miller"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/8227"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/8227","href":"https://scholarscompass.vcu.edu/etd/8227","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/Q3Q6-Z095","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/Q3Q6-Z095","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avcu%3Aoai%3Ascholarscompass.vcu.edu%3Aetd-9407","prefix":"oai_dc"},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=qualified-dublin-core&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-9407","prefix":"qualified-dublin-core"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mo Jiang"]},{"key":"dc:creator","label":"Author","values":["Miller, Carter M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2030-12-11T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-12-12T08:00:00Z"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["VCU University Archives","VCU Theses and Dissertations"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Life Science Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Process Control and Systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© Carter Miller"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/Q3Q6-Z095","https://scholarscompass.vcu.edu/etd/8227"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A low-cost and fully controllable microwave reactor was developed using accessible and commercially available equipment for use in laboratory scale solid state chemistry. The design used a magnetron as the source of electromagnetic radiation to heat the sample. A domestic microwave cavity was repurposed as the resonance chamber to ensure safe confinement of electromagnetic radiation while providing a sufficiently large volume for solid samples and reaction vessels. The power delivery to the magnetron was modulated by an inverter circuit with sufficiently high response time to be controlled with a PWM signal from a microcontroller. An IR sensor was implemented to both monitor and provide a signal for a feedback control loop. Paired with the rapid power modulation of the inverter circuit, heating rate and temperature can be controlled allowing for reliable chemical processing in a wide range of temperatures. To allow for facile control and monitoring of chemical processes in real time, a user interface was implemented to change important process parameters, monitor temperature and power use, and store data from runs for further analysis. To ensure longevity of the reactor, a cooling loop was implemented to cool the magnetron from overheating. The performance was demonstrated using a dehydration reaction of nickel oxalate dihydrate in anhydrous nickel oxalate. Results demonstrate reliable heating of samples for kinetic analysis. Overall, this work provides an accessible and modular platform of a microwave reactor that has applications in kinetic reaction analysis and intensification of solid-state chemical processing.</p>"]},{"key":"dc:title","label":"Title","values":["Low-Cost Temperature Monitoring and Control for Microwave Solid Reactor"]}]}],"canonical_facts":{"dc:contributor":["Mo Jiang"],"dc:creator":["Miller, Carter M"],"dc:date.available":["2030-12-11T08:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:date.submitted":["2025-12-12T08:00:00Z"],"dc:description.abstract":["<p>A low-cost and fully controllable microwave reactor was developed using accessible and commercially available equipment for use in laboratory scale solid state chemistry. The design used a magnetron as the source of electromagnetic radiation to heat the sample. A domestic microwave cavity was repurposed as the resonance chamber to ensure safe confinement of electromagnetic radiation while providing a sufficiently large volume for solid samples and reaction vessels. The power delivery to the magnetron was modulated by an inverter circuit with sufficiently high response time to be controlled with a PWM signal from a microcontroller. An IR sensor was implemented to both monitor and provide a signal for a feedback control loop. Paired with the rapid power modulation of the inverter circuit, heating rate and temperature can be controlled allowing for reliable chemical processing in a wide range of temperatures. To allow for facile control and monitoring of chemical processes in real time, a user interface was implemented to change important process parameters, monitor temperature and power use, and store data from runs for further analysis. To ensure longevity of the reactor, a cooling loop was implemented to cool the magnetron from overheating. The performance was demonstrated using a dehydration reaction of nickel oxalate dihydrate in anhydrous nickel oxalate. Results demonstrate reliable heating of samples for kinetic analysis. Overall, this work provides an accessible and modular platform of a microwave reactor that has applications in kinetic reaction analysis and intensification of solid-state chemical processing.</p>"],"dc:identifier":["https://doi.org/10.25772/Q3Q6-Z095","https://scholarscompass.vcu.edu/etd/8227"],"dc:relation.ispartof":["VCU University Archives","VCU Theses and Dissertations"],"dc:rights":["© Carter Miller"],"dc:subject":["Process Control and Systems"],"dc:title":["Low-Cost Temperature Monitoring and Control for Microwave Solid Reactor"],"thesis:degree_discipline":["Chemical and Life Science Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-27T10:08:55Z"}