{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-9420"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-9420","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"FeCrAl and Cr-Coated Zircaloy-4 Surface Oxidation Chemistry After Short-Time High-Temperature Heating in a Steam Environment","abstract":"<p>Chromium (Cr)-Coated Zirconium (Zr) alloy and Iron-chromium-aluminum (FeCrAl) Alloys have been proposed as accident-tolerant fuel (ATF) cladding replacements for traditional Zr-alloy cladding. Previous research has been conducted showing higher oxidation resistances of Cr-Coated Zr and FeCrAl in air and some in a steam environment, but there is a present lack of studies that include a high heating rate, high temperature, low time, and quenching, which are crucial elements of certain accident scenarios. A testing apparatus with induction heating was used to simulate accident scenarios. Two coating methods for Cr-coated Zircaloy 4, powder vapor deposition (PVD) and cold spray (CS), and four FeCrAl Alloys, APMT, C26M, FA-SMT, and PM-C26M, were rapidly heated to high temperatures in a steam environment with a heating rate of 93°C/s. Targeting temperatures of 1200°C, 1300°C, 1400°C, and 1500°C were used, with a 1min hold time, followed by quick quenching in water. PVD samples showed an evolution of a protective chromia layer from 1200°C to 1400°C, and CS samples showed a similar evolution from 1200°C to 1300°C. APMT samples showed a small protective Al2O3 oxide layer formed between 1200°C and 1300◦C, along with a surface layer of chromia. C26M, FA-SMT, and PM-C26M samples all showed a thin protective Al<sub>2</sub>O<sub>3</sub> oxide layer at the surface from 1200°C to 1300°C. All FeCrAl and cold-spray samples failed to survive beyond 1400◦C and burst before reaching the target temperature. PVD failed to reach 1500◦C and burst before a stable temperature was achieved.</p>","abstract_html":"&lt;p&gt;Chromium (Cr)-Coated Zirconium (Zr) alloy and Iron-chromium-aluminum (FeCrAl) Alloys have been proposed as accident-tolerant fuel (ATF) cladding replacements for traditional Zr-alloy cladding. Previous research has been conducted showing higher oxidation resistances of Cr-Coated Zr and FeCrAl in air and some in a steam environment, but there is a present lack of studies that include a high heating rate, high temperature, low time, and quenching, which are crucial elements of certain accident scenarios. A testing apparatus with induction heating was used to simulate accident scenarios. Two coating methods for Cr-coated Zircaloy 4, powder vapor deposition (PVD) and cold spray (CS), and four FeCrAl Alloys, APMT, C26M, FA-SMT, and PM-C26M, were rapidly heated to high temperatures in a steam environment with a heating rate of 93°C/s. Targeting temperatures of 1200°C, 1300°C, 1400°C, and 1500°C were used, with a 1min hold time, followed by quick quenching in water. PVD samples showed an evolution of a protective chromia layer from 1200°C to 1400°C, and CS samples showed a similar evolution from 1200°C to 1300°C. APMT samples showed a small protective Al2O3 oxide layer formed between 1200°C and 1300◦C, along with a surface layer of chromia. C26M, FA-SMT, and PM-C26M samples all showed a thin protective Al&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;3&lt;/sub&gt; oxide layer at the surface from 1200°C to 1300°C. All FeCrAl and cold-spray samples failed to survive beyond 1400◦C and burst before reaching the target temperature. PVD failed to reach 1500◦C and burst before a stable temperature was achieved.&lt;/p&gt;","abstract_has_math":false,"creators":["Miller, Lilith"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Mechanical and Nuclear Engineering","degree_department":null,"school":null,"contributors":["Carlos Castano Londono"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-01-01T08:00:00Z","date_published":"2025-01-01T08:00:00Z","updated_at":"2026-11-27T10:09:03Z","subjects":["FeCrAl","Zircaloy","Accident tolerant fuel","Oxidation","Metallurgy","Nuclear Engineering","Other Materials Science and Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/8240"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/8240","href":"https://scholarscompass.vcu.edu/etd/8240","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/TTPB-CD38","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/TTPB-CD38","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avcu%3Aoai%3Ascholarscompass.vcu.edu%3Aetd-9420","prefix":"oai_dc"},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=qualified-dublin-core&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-9420","prefix":"qualified-dublin-core"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Carlos Castano Londono"]},{"key":"dc:creator","label":"Author","values":["Miller, Lilith"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-12-16T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-12-16T08:00:00Z"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["VCU University Archives","VCU Theses and Dissertations"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Nuclear Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FeCrAl","Zircaloy","Accident tolerant fuel","Oxidation","Metallurgy","Nuclear Engineering","Other Materials Science and Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/TTPB-CD38","https://scholarscompass.vcu.edu/etd/8240"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Chromium (Cr)-Coated Zirconium (Zr) alloy and Iron-chromium-aluminum (FeCrAl) Alloys have been proposed as accident-tolerant fuel (ATF) cladding replacements for traditional Zr-alloy cladding. Previous research has been conducted showing higher oxidation resistances of Cr-Coated Zr and FeCrAl in air and some in a steam environment, but there is a present lack of studies that include a high heating rate, high temperature, low time, and quenching, which are crucial elements of certain accident scenarios. A testing apparatus with induction heating was used to simulate accident scenarios. Two coating methods for Cr-coated Zircaloy 4, powder vapor deposition (PVD) and cold spray (CS), and four FeCrAl Alloys, APMT, C26M, FA-SMT, and PM-C26M, were rapidly heated to high temperatures in a steam environment with a heating rate of 93°C/s. Targeting temperatures of 1200°C, 1300°C, 1400°C, and 1500°C were used, with a 1min hold time, followed by quick quenching in water. PVD samples showed an evolution of a protective chromia layer from 1200°C to 1400°C, and CS samples showed a similar evolution from 1200°C to 1300°C. APMT samples showed a small protective Al2O3 oxide layer formed between 1200°C and 1300◦C, along with a surface layer of chromia. C26M, FA-SMT, and PM-C26M samples all showed a thin protective Al<sub>2</sub>O<sub>3</sub> oxide layer at the surface from 1200°C to 1300°C. All FeCrAl and cold-spray samples failed to survive beyond 1400◦C and burst before reaching the target temperature. PVD failed to reach 1500◦C and burst before a stable temperature was achieved.</p>"]},{"key":"dc:title","label":"Title","values":["FeCrAl and Cr-Coated Zircaloy-4 Surface Oxidation Chemistry After Short-Time High-Temperature Heating in a Steam Environment"]}]}],"canonical_facts":{"dc:contributor":["Carlos Castano Londono"],"dc:creator":["Miller, Lilith"],"dc:date.available":["2026-12-16T08:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:date.submitted":["2025-12-16T08:00:00Z"],"dc:description.abstract":["<p>Chromium (Cr)-Coated Zirconium (Zr) alloy and Iron-chromium-aluminum (FeCrAl) Alloys have been proposed as accident-tolerant fuel (ATF) cladding replacements for traditional Zr-alloy cladding. Previous research has been conducted showing higher oxidation resistances of Cr-Coated Zr and FeCrAl in air and some in a steam environment, but there is a present lack of studies that include a high heating rate, high temperature, low time, and quenching, which are crucial elements of certain accident scenarios. A testing apparatus with induction heating was used to simulate accident scenarios. Two coating methods for Cr-coated Zircaloy 4, powder vapor deposition (PVD) and cold spray (CS), and four FeCrAl Alloys, APMT, C26M, FA-SMT, and PM-C26M, were rapidly heated to high temperatures in a steam environment with a heating rate of 93°C/s. Targeting temperatures of 1200°C, 1300°C, 1400°C, and 1500°C were used, with a 1min hold time, followed by quick quenching in water. PVD samples showed an evolution of a protective chromia layer from 1200°C to 1400°C, and CS samples showed a similar evolution from 1200°C to 1300°C. APMT samples showed a small protective Al2O3 oxide layer formed between 1200°C and 1300◦C, along with a surface layer of chromia. C26M, FA-SMT, and PM-C26M samples all showed a thin protective Al<sub>2</sub>O<sub>3</sub> oxide layer at the surface from 1200°C to 1300°C. All FeCrAl and cold-spray samples failed to survive beyond 1400◦C and burst before reaching the target temperature. PVD failed to reach 1500◦C and burst before a stable temperature was achieved.</p>"],"dc:identifier":["https://doi.org/10.25772/TTPB-CD38","https://scholarscompass.vcu.edu/etd/8240"],"dc:relation.ispartof":["VCU University Archives","VCU Theses and Dissertations"],"dc:rights":["© The Author"],"dc:subject":["FeCrAl","Zircaloy","Accident tolerant fuel","Oxidation","Metallurgy","Nuclear Engineering","Other Materials Science and Engineering"],"dc:title":["FeCrAl and Cr-Coated Zircaloy-4 Surface Oxidation Chemistry After Short-Time High-Temperature Heating in a Steam Environment"],"thesis:degree_discipline":["Mechanical and Nuclear Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-27T10:09:03Z"}