{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-9624"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-9624","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Comparison of Artificial Intelligence vs Human Observer For Periapical Radiolucency Detection","abstract":"Objective: The aim of this study was to assess the performance of an Artificial Intelligence (AI) program (OverJet AI) with that of experienced endodontic residents, endodontists, a radiologist, and dental students in detecting periapical radiolucencies using radiographic images. Methods: One hundred and fifty periapical radiographic images were analyzed using the OverJet AI software to determine the presence/absence of a periapical radiolucency as well as the size (small 1-3mm, medium 4-6mm, and large 6+mm). The unaltered images were also evaluated by two endodontic residents, two practicing endodontists, an oral radiologist and two 4th year dental students. Results: Agreement between the AI system and human observers was comparable to interobserver agreement among clinicians, with kappa values indicating moderate to substantial agreement for both detection and size classification of periapical radiolucencies. Additionally, the AI demonstrated strong diagnostic performance with 87% sensitivity and 82% specificity when compared against experienced Endodontists. Conclusions: OverJet AI demonstrated comparable diagnostic ability to dental professionals in detecting periapical pathology. The results suggest that AI could be a valuable tool when reading and assessing periapical radiolucencies. Further research is needed as the technologies continue to improve and develop.","abstract_html":"Objective: The aim of this study was to assess the performance of an Artificial Intelligence (AI) program (OverJet AI) with that of experienced endodontic residents, endodontists, a radiologist, and dental students in detecting periapical radiolucencies using radiographic images. Methods: One hundred and fifty periapical radiographic images were analyzed using the OverJet AI software to determine the presence/absence of a periapical radiolucency as well as the size (small 1-3mm, medium 4-6mm, and large 6+mm). The unaltered images were also evaluated by two endodontic residents, two practicing endodontists, an oral radiologist and two 4th year dental students. Results: Agreement between the AI system and human observers was comparable to interobserver agreement among clinicians, with kappa values indicating moderate to substantial agreement for both detection and size classification of periapical radiolucencies. Additionally, the AI demonstrated strong diagnostic performance with 87% sensitivity and 82% specificity when compared against experienced Endodontists. Conclusions: OverJet AI demonstrated comparable diagnostic ability to dental professionals in detecting periapical pathology. The results suggest that AI could be a valuable tool when reading and assessing periapical radiolucencies. Further research is needed as the technologies continue to improve and develop.","abstract_has_math":false,"creators":["Pink, Adam J"],"institution":null,"degree_name":"Master of Science in Dentistry","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Dr. Garry Myers","Dr. Caroline Carrico","Dr. Anusha Vaddi"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:16:27Z","subjects":["Artificial Intelligence","periapical radiolucency","overjet AI","Oral and Maxillofacial Radiology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/8434"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/8434","href":"https://scholarscompass.vcu.edu/etd/8434","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/8r9j-hj60","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/8r9j-hj60","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-9624","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Garry Myers","Dr. Caroline Carrico","Dr. Anusha Vaddi"]},{"key":"dc:creator","label":"Author","values":["Pink, Adam J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-02T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Artificial Intelligence","periapical radiolucency","overjet AI","Oral and Maxillofacial Radiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/8r9j-hj60","https://scholarscompass.vcu.edu/etd/8434"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objective: The aim of this study was to assess the performance of an Artificial Intelligence (AI) program (OverJet AI) with that of experienced endodontic residents, endodontists, a radiologist, and dental students in detecting periapical radiolucencies using radiographic images. Methods: One hundred and fifty periapical radiographic images were analyzed using the OverJet AI software to determine the presence/absence of a periapical radiolucency as well as the size (small 1-3mm, medium 4-6mm, and large 6+mm). The unaltered images were also evaluated by two endodontic residents, two practicing endodontists, an oral radiologist and two 4th year dental students. Results: Agreement between the AI system and human observers was comparable to interobserver agreement among clinicians, with kappa values indicating moderate to substantial agreement for both detection and size classification of periapical radiolucencies. Additionally, the AI demonstrated strong diagnostic performance with 87% sensitivity and 82% specificity when compared against experienced Endodontists. Conclusions: OverJet AI demonstrated comparable diagnostic ability to dental professionals in detecting periapical pathology. The results suggest that AI could be a valuable tool when reading and assessing periapical radiolucencies. Further research is needed as the technologies continue to improve and develop."]},{"key":"dc:title","label":"Title","values":["Comparison of Artificial Intelligence vs Human Observer For Periapical Radiolucency Detection"]}]}],"canonical_facts":{"dc:contributor":["Dr. Garry Myers","Dr. Caroline Carrico","Dr. Anusha Vaddi"],"dc:creator":["Pink, Adam J"],"dc:date.available":["2026-06-02T07:00:00Z"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:description.abstract":["Objective: The aim of this study was to assess the performance of an Artificial Intelligence (AI) program (OverJet AI) with that of experienced endodontic residents, endodontists, a radiologist, and dental students in detecting periapical radiolucencies using radiographic images. Methods: One hundred and fifty periapical radiographic images were analyzed using the OverJet AI software to determine the presence/absence of a periapical radiolucency as well as the size (small 1-3mm, medium 4-6mm, and large 6+mm). The unaltered images were also evaluated by two endodontic residents, two practicing endodontists, an oral radiologist and two 4th year dental students. Results: Agreement between the AI system and human observers was comparable to interobserver agreement among clinicians, with kappa values indicating moderate to substantial agreement for both detection and size classification of periapical radiolucencies. Additionally, the AI demonstrated strong diagnostic performance with 87% sensitivity and 82% specificity when compared against experienced Endodontists. Conclusions: OverJet AI demonstrated comparable diagnostic ability to dental professionals in detecting periapical pathology. The results suggest that AI could be a valuable tool when reading and assessing periapical radiolucencies. Further research is needed as the technologies continue to improve and develop."],"dc:identifier":["https://doi.org/10.25772/8r9j-hj60","https://scholarscompass.vcu.edu/etd/8434"],"dc:rights":["© The Author"],"dc:subject":["Artificial Intelligence","periapical radiolucency","overjet AI","Oral and Maxillofacial Radiology"],"dc:title":["Comparison of Artificial Intelligence vs Human Observer For Periapical Radiolucency Detection"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Dentistry"]},"updated_at":"2026-11-19T09:16:27Z"}