{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-9634"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-9634","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors: A Randomized Controlled Trial","abstract":"<p><strong>Objective</strong>: Predictable maxillary lateral incisor extrusion with clear aligners remains a clinical challenge. Clinicians often select attachment design based on anecdotal experience rather than prospective evidence. This multicenter randomized controlled trial compared the clinical efficacy of Invisalign optimized extrusion attachments against three sizes of horizontal gingivally-beveled attachments (1×1×3 mm, 1×1×4 mm, 1×1×5 mm) and evaluated patient esthetic perceptions of each.</p> <p><strong>Methods</strong>: Patients requiring at least 0.5 mm of maxillary lateral incisor extrusion were recruited across four clinical sites. Targeted incisors were randomized into four groups: Optimized (O), or Horizontal 3mm (H3), 4mm (H4), and 5mm (H5). Digital models (Pretreatment, Predicted, and Posttreatment) were superimposed using Geomagic software to quantify extrusion accuracy. Patient esthetic satisfaction was captured via a REDCap survey using a 5-point Likert scale.</p> <p><strong>Results</strong>: Thirty-one teeth from 18 patients were analyzed. Achieved extrusion was significantly lower than predicted, with a median of 70% of planned movement. Optimized attachments produced significantly greater extrusion than horizontal gingivally beveled attachments (92% vs. 52%; p=0.0108), while no significant differences were observed among horizontal attachment sizes. Survey results indicated high esthetic satisfaction across all cohorts. No statistically significant differences in esthetic perception were observed between attachment designs.</p> <p><strong>Conclusion</strong>: Optimized extrusion attachments significantly outperformed horizontal gingivally beveled attachments, achieving greater extrusion efficiency without compromising esthetics. Increasing horizontal attachment size did not improve extrusion outcomes. Optimized attachments are therefore recommended for maxillary lateral incisor extrusion with Invisalign.</p>","abstract_html":"&lt;p&gt;&lt;strong&gt;Objective&lt;/strong&gt;: Predictable maxillary lateral incisor extrusion with clear aligners remains a clinical challenge. Clinicians often select attachment design based on anecdotal experience rather than prospective evidence. This multicenter randomized controlled trial compared the clinical efficacy of Invisalign optimized extrusion attachments against three sizes of horizontal gingivally-beveled attachments (1×1×3 mm, 1×1×4 mm, 1×1×5 mm) and evaluated patient esthetic perceptions of each.&lt;/p&gt; &lt;p&gt;&lt;strong&gt;Methods&lt;/strong&gt;: Patients requiring at least 0.5 mm of maxillary lateral incisor extrusion were recruited across four clinical sites. Targeted incisors were randomized into four groups: Optimized (O), or Horizontal 3mm (H3), 4mm (H4), and 5mm (H5). Digital models (Pretreatment, Predicted, and Posttreatment) were superimposed using Geomagic software to quantify extrusion accuracy. Patient esthetic satisfaction was captured via a REDCap survey using a 5-point Likert scale.&lt;/p&gt; &lt;p&gt;&lt;strong&gt;Results&lt;/strong&gt;: Thirty-one teeth from 18 patients were analyzed. Achieved extrusion was significantly lower than predicted, with a median of 70% of planned movement. Optimized attachments produced significantly greater extrusion than horizontal gingivally beveled attachments (92% vs. 52%; p=0.0108), while no significant differences were observed among horizontal attachment sizes. Survey results indicated high esthetic satisfaction across all cohorts. No statistically significant differences in esthetic perception were observed between attachment designs.&lt;/p&gt; &lt;p&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;: Optimized extrusion attachments significantly outperformed horizontal gingivally beveled attachments, achieving greater extrusion efficiency without compromising esthetics. Increasing horizontal attachment size did not improve extrusion outcomes. Optimized attachments are therefore recommended for maxillary lateral incisor extrusion with Invisalign.&lt;/p&gt;","abstract_has_math":false,"creators":["Catalano, Alexis M"],"institution":null,"degree_name":"Master of Science in Dentistry","degree_level":"Thesis","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":["Christina Philips","Steven Lindauer","Bhavna Shroff","Caroline Carrico","Parthasarthy Madurantakam"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-01-01T08:00:00Z","date_published":"2026-01-01T08:00:00Z","updated_at":"2026-11-27T10:09:10Z","subjects":["clear aligners","lateral incisor extrusion","attachment design","Dental Materials","Orthodontics and Orthodontology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/8439"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/8439","href":"https://scholarscompass.vcu.edu/etd/8439","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/cpw0-1z30","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/cpw0-1z30","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avcu%3Aoai%3Ascholarscompass.vcu.edu%3Aetd-9634","prefix":"oai_dc"},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=qualified-dublin-core&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-9634","prefix":"qualified-dublin-core"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christina Philips","Steven Lindauer","Bhavna Shroff","Caroline Carrico","Parthasarthy Madurantakam"]},{"key":"dc:creator","label":"Author","values":["Catalano, Alexis M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2028-06-16T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-06-17T07:00:00Z"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["VCU University Archives","VCU Theses and Dissertations"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["clear aligners","lateral incisor extrusion","attachment design","Dental Materials","Orthodontics and Orthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/cpw0-1z30","https://scholarscompass.vcu.edu/etd/8439"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p><strong>Objective</strong>: Predictable maxillary lateral incisor extrusion with clear aligners remains a clinical challenge. Clinicians often select attachment design based on anecdotal experience rather than prospective evidence. This multicenter randomized controlled trial compared the clinical efficacy of Invisalign optimized extrusion attachments against three sizes of horizontal gingivally-beveled attachments (1×1×3 mm, 1×1×4 mm, 1×1×5 mm) and evaluated patient esthetic perceptions of each.</p> <p><strong>Methods</strong>: Patients requiring at least 0.5 mm of maxillary lateral incisor extrusion were recruited across four clinical sites. Targeted incisors were randomized into four groups: Optimized (O), or Horizontal 3mm (H3), 4mm (H4), and 5mm (H5). Digital models (Pretreatment, Predicted, and Posttreatment) were superimposed using Geomagic software to quantify extrusion accuracy. Patient esthetic satisfaction was captured via a REDCap survey using a 5-point Likert scale.</p> <p><strong>Results</strong>: Thirty-one teeth from 18 patients were analyzed. Achieved extrusion was significantly lower than predicted, with a median of 70% of planned movement. Optimized attachments produced significantly greater extrusion than horizontal gingivally beveled attachments (92% vs. 52%; p=0.0108), while no significant differences were observed among horizontal attachment sizes. Survey results indicated high esthetic satisfaction across all cohorts. No statistically significant differences in esthetic perception were observed between attachment designs.</p> <p><strong>Conclusion</strong>: Optimized extrusion attachments significantly outperformed horizontal gingivally beveled attachments, achieving greater extrusion efficiency without compromising esthetics. Increasing horizontal attachment size did not improve extrusion outcomes. Optimized attachments are therefore recommended for maxillary lateral incisor extrusion with Invisalign.</p>"]},{"key":"dc:title","label":"Title","values":["Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors: A Randomized Controlled Trial"]}]}],"canonical_facts":{"dc:contributor":["Christina Philips","Steven Lindauer","Bhavna Shroff","Caroline Carrico","Parthasarthy Madurantakam"],"dc:creator":["Catalano, Alexis M"],"dc:date.available":["2028-06-16T07:00:00Z"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:date.submitted":["2026-06-17T07:00:00Z"],"dc:description.abstract":["<p><strong>Objective</strong>: Predictable maxillary lateral incisor extrusion with clear aligners remains a clinical challenge. Clinicians often select attachment design based on anecdotal experience rather than prospective evidence. This multicenter randomized controlled trial compared the clinical efficacy of Invisalign optimized extrusion attachments against three sizes of horizontal gingivally-beveled attachments (1×1×3 mm, 1×1×4 mm, 1×1×5 mm) and evaluated patient esthetic perceptions of each.</p> <p><strong>Methods</strong>: Patients requiring at least 0.5 mm of maxillary lateral incisor extrusion were recruited across four clinical sites. Targeted incisors were randomized into four groups: Optimized (O), or Horizontal 3mm (H3), 4mm (H4), and 5mm (H5). Digital models (Pretreatment, Predicted, and Posttreatment) were superimposed using Geomagic software to quantify extrusion accuracy. Patient esthetic satisfaction was captured via a REDCap survey using a 5-point Likert scale.</p> <p><strong>Results</strong>: Thirty-one teeth from 18 patients were analyzed. Achieved extrusion was significantly lower than predicted, with a median of 70% of planned movement. Optimized attachments produced significantly greater extrusion than horizontal gingivally beveled attachments (92% vs. 52%; p=0.0108), while no significant differences were observed among horizontal attachment sizes. Survey results indicated high esthetic satisfaction across all cohorts. No statistically significant differences in esthetic perception were observed between attachment designs.</p> <p><strong>Conclusion</strong>: Optimized extrusion attachments significantly outperformed horizontal gingivally beveled attachments, achieving greater extrusion efficiency without compromising esthetics. Increasing horizontal attachment size did not improve extrusion outcomes. Optimized attachments are therefore recommended for maxillary lateral incisor extrusion with Invisalign.</p>"],"dc:identifier":["https://doi.org/10.25772/cpw0-1z30","https://scholarscompass.vcu.edu/etd/8439"],"dc:relation.ispartof":["VCU University Archives","VCU Theses and Dissertations"],"dc:rights":["© The Author"],"dc:subject":["clear aligners","lateral incisor extrusion","attachment design","Dental Materials","Orthodontics and Orthodontology"],"dc:title":["Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors: A Randomized Controlled Trial"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Dentistry"]},"updated_at":"2026-11-27T10:09:10Z"}