{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd_retro-1077"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd_retro-1077","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Effect of Storage Temperatures of Panavia F on the Retention of Prefabricated Dowels","abstract":"Statement of Problem. Resin-based cements have become increasingly more popular for the cementation of prefabricated endodontic dowels due to their superior retention. The manufacturer of Panavia F 2.0 suggests that the product be stored under refrigerated conditions while not in use, however, there is no literature to support such a rationale. It is possible that these storage/use temperature cycling events may have a deleterious effect on the retention of prefabricated endodontic dowels. Purpose. The purpose of this in-vitro study was to investigate the retention of Panavia F 2.0 used to lute prefabricated endodontic dowels after the Panavia F 2.0 system has been kept under different storage conditions. Material and Methods. Sixty-four extracted human central incisors were selected to undergo root canal therapy and dowel retention testing. Four separate Panavia F 2.0 cement systems were placed under 4 different storage conditions for a period of 6 months, until retention testing was initiated. In the first group, the Panavia F 2.0 was stored under the manufacturer's suggested refrigerated conditions, at a constant temperature of 40°F. In the second group, the Panavia F 2.0 was stored under a constant 90°F temperature. In the third group, the Panavia F 2.0 was stored under room temperature conditions of 70°F. The fourth group attempted to mimic clinical usage conditions with the Panavia F 2.0 being cycled from refrigeration at 40°F for 22 hours/day to 2 hours/day of room temperature at 70°F 5 days per week for the duration of the 6-month storage condition period. Results. Stress values were analyzed using 1-way ANOVA. A Tukey's HSD multiple comparison analysis of the dowel retention strengths indicated that the group stored at 90°F resulted in the lowest retention. This group was significantly lower than all other groups' retention strength (p Conclusions. Within the limitations of this study, the storage of Panavia F 2.0 at either room temperature or cycling between refrigeration and room temperature yields similar dowel retention values. However, the storage of Panavia F 2.0 at temperatures of 90°F for prolonged periods causes poor dowel retention. Clinical Implications The results of this study do not support the necessity of storing Panavia F 2.0 under refrigerated conditions between clinical uses, if used within six months. However, the storage of the Panavia F 2.0 cementation system at temperatures of 90°F for prolonged periods will affect dowel retention and is therefore not advisable.","abstract_html":"Statement of Problem. Resin-based cements have become increasingly more popular for the cementation of prefabricated endodontic dowels due to their superior retention. The manufacturer of Panavia F 2.0 suggests that the product be stored under refrigerated conditions while not in use, however, there is no literature to support such a rationale. It is possible that these storage/use temperature cycling events may have a deleterious effect on the retention of prefabricated endodontic dowels. Purpose. The purpose of this in-vitro study was to investigate the retention of Panavia F 2.0 used to lute prefabricated endodontic dowels after the Panavia F 2.0 system has been kept under different storage conditions. Material and Methods. Sixty-four extracted human central incisors were selected to undergo root canal therapy and dowel retention testing. Four separate Panavia F 2.0 cement systems were placed under 4 different storage conditions for a period of 6 months, until retention testing was initiated. In the first group, the Panavia F 2.0 was stored under the manufacturer&#x27;s suggested refrigerated conditions, at a constant temperature of 40°F. In the second group, the Panavia F 2.0 was stored under a constant 90°F temperature. In the third group, the Panavia F 2.0 was stored under room temperature conditions of 70°F. The fourth group attempted to mimic clinical usage conditions with the Panavia F 2.0 being cycled from refrigeration at 40°F for 22 hours/day to 2 hours/day of room temperature at 70°F 5 days per week for the duration of the 6-month storage condition period. Results. Stress values were analyzed using 1-way ANOVA. A Tukey&#x27;s HSD multiple comparison analysis of the dowel retention strengths indicated that the group stored at 90°F resulted in the lowest retention. This group was significantly lower than all other groups&#x27; retention strength (p Conclusions. Within the limitations of this study, the storage of Panavia F 2.0 at either room temperature or cycling between refrigeration and room temperature yields similar dowel retention values. However, the storage of Panavia F 2.0 at temperatures of 90°F for prolonged periods causes poor dowel retention. Clinical Implications The results of this study do not support the necessity of storing Panavia F 2.0 under refrigerated conditions between clinical uses, if used within six months. However, the storage of the Panavia F 2.0 cementation system at temperatures of 90°F for prolonged periods will affect dowel retention and is therefore not advisable.","abstract_has_math":false,"creators":["Schleider, David Mark"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Prosthodontics","degree_department":null,"school":null,"contributors":["Dr. David R. Burns"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:15:52Z","subjects":["Storage conditions","Panavia","Dowels","Thermocycling","Dentistry","Medicine and Health Sciences","Prosthodontics and Prosthodontology"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarscompass.vcu.edu/etd_retro/78","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarscompass.vcu.edu/etd_retro/78","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd_retro-1077","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. David R. Burns"]},{"key":"dc:creator","label":"Author","values":["Schleider, David Mark"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-12-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2005-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Prosthodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Storage conditions","Panavia","Dowels","Thermocycling","Dentistry","Medicine and Health Sciences","Prosthodontics and Prosthodontology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd_retro/78"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Statement of Problem. Resin-based cements have become increasingly more popular for the cementation of prefabricated endodontic dowels due to their superior retention. The manufacturer of Panavia F 2.0 suggests that the product be stored under refrigerated conditions while not in use, however, there is no literature to support such a rationale. It is possible that these storage/use temperature cycling events may have a deleterious effect on the retention of prefabricated endodontic dowels. Purpose. The purpose of this in-vitro study was to investigate the retention of Panavia F 2.0 used to lute prefabricated endodontic dowels after the Panavia F 2.0 system has been kept under different storage conditions. Material and Methods. Sixty-four extracted human central incisors were selected to undergo root canal therapy and dowel retention testing. Four separate Panavia F 2.0 cement systems were placed under 4 different storage conditions for a period of 6 months, until retention testing was initiated. In the first group, the Panavia F 2.0 was stored under the manufacturer's suggested refrigerated conditions, at a constant temperature of 40°F. In the second group, the Panavia F 2.0 was stored under a constant 90°F temperature. In the third group, the Panavia F 2.0 was stored under room temperature conditions of 70°F. The fourth group attempted to mimic clinical usage conditions with the Panavia F 2.0 being cycled from refrigeration at 40°F for 22 hours/day to 2 hours/day of room temperature at 70°F 5 days per week for the duration of the 6-month storage condition period. Results. Stress values were analyzed using 1-way ANOVA. A Tukey's HSD multiple comparison analysis of the dowel retention strengths indicated that the group stored at 90°F resulted in the lowest retention. This group was significantly lower than all other groups' retention strength (p Conclusions. Within the limitations of this study, the storage of Panavia F 2.0 at either room temperature or cycling between refrigeration and room temperature yields similar dowel retention values. However, the storage of Panavia F 2.0 at temperatures of 90°F for prolonged periods causes poor dowel retention. Clinical Implications The results of this study do not support the necessity of storing Panavia F 2.0 under refrigerated conditions between clinical uses, if used within six months. However, the storage of the Panavia F 2.0 cementation system at temperatures of 90°F for prolonged periods will affect dowel retention and is therefore not advisable."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Part of Retrospective ETD Collection, restricted to VCU only."]},{"key":"dc:title","label":"Title","values":["Effect of Storage Temperatures of Panavia F on the Retention of Prefabricated Dowels"]}]}],"canonical_facts":{"dc:contributor":["Dr. David R. Burns"],"dc:creator":["Schleider, David Mark"],"dc:date.available":["2024-12-09T08:00:00Z"],"dc:date.created":["2005-01-01T08:00:00Z"],"dc:description.abstract":["Statement of Problem. Resin-based cements have become increasingly more popular for the cementation of prefabricated endodontic dowels due to their superior retention. The manufacturer of Panavia F 2.0 suggests that the product be stored under refrigerated conditions while not in use, however, there is no literature to support such a rationale. It is possible that these storage/use temperature cycling events may have a deleterious effect on the retention of prefabricated endodontic dowels. Purpose. The purpose of this in-vitro study was to investigate the retention of Panavia F 2.0 used to lute prefabricated endodontic dowels after the Panavia F 2.0 system has been kept under different storage conditions. Material and Methods. Sixty-four extracted human central incisors were selected to undergo root canal therapy and dowel retention testing. Four separate Panavia F 2.0 cement systems were placed under 4 different storage conditions for a period of 6 months, until retention testing was initiated. In the first group, the Panavia F 2.0 was stored under the manufacturer's suggested refrigerated conditions, at a constant temperature of 40°F. In the second group, the Panavia F 2.0 was stored under a constant 90°F temperature. In the third group, the Panavia F 2.0 was stored under room temperature conditions of 70°F. The fourth group attempted to mimic clinical usage conditions with the Panavia F 2.0 being cycled from refrigeration at 40°F for 22 hours/day to 2 hours/day of room temperature at 70°F 5 days per week for the duration of the 6-month storage condition period. Results. Stress values were analyzed using 1-way ANOVA. A Tukey's HSD multiple comparison analysis of the dowel retention strengths indicated that the group stored at 90°F resulted in the lowest retention. This group was significantly lower than all other groups' retention strength (p Conclusions. Within the limitations of this study, the storage of Panavia F 2.0 at either room temperature or cycling between refrigeration and room temperature yields similar dowel retention values. However, the storage of Panavia F 2.0 at temperatures of 90°F for prolonged periods causes poor dowel retention. Clinical Implications The results of this study do not support the necessity of storing Panavia F 2.0 under refrigerated conditions between clinical uses, if used within six months. However, the storage of the Panavia F 2.0 cementation system at temperatures of 90°F for prolonged periods will affect dowel retention and is therefore not advisable."],"dc:description.note":["Part of Retrospective ETD Collection, restricted to VCU only."],"dc:identifier":["https://scholarscompass.vcu.edu/etd_retro/78"],"dc:rights":["© The Author"],"dc:subject":["Storage conditions","Panavia","Dowels","Thermocycling","Dentistry","Medicine and Health Sciences","Prosthodontics and Prosthodontology"],"dc:title":["Effect of Storage Temperatures of Panavia F on the Retention of Prefabricated Dowels"],"thesis:degree_discipline":["Prosthodontics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:15:52Z"}