{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd_retro-1106"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd_retro-1106","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta.","abstract":"Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro and animal trials are conducted to study the flow fields in artificial ventricles to avoid hemolysis and thrombosis but the effects of flow fields corresponding to the angle of LVAD insertion into the aorta are often neglected. This experiment uses 30, 60 and 90 degree glass models to signify different angles of the surgical end to side anastomosis. Particle Image Velocimetry is used to study the flow fields at the interface and determine optimum angle amongst the three to avoid blood trauma. Use of a 30 degree glass interface minimizes stagnation zone, recirculation patterns, flow reversal, high shear region and other flow irregularities which may lead to reduced hemolysis, thrombosis and blood trauma in a clinical setting.","abstract_html":"Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro and animal trials are conducted to study the flow fields in artificial ventricles to avoid hemolysis and thrombosis but the effects of flow fields corresponding to the angle of LVAD insertion into the aorta are often neglected. This experiment uses 30, 60 and 90 degree glass models to signify different angles of the surgical end to side anastomosis. Particle Image Velocimetry is used to study the flow fields at the interface and determine optimum angle amongst the three to avoid blood trauma. Use of a 30 degree glass interface minimizes stagnation zone, recirculation patterns, flow reversal, high shear region and other flow irregularities which may lead to reduced hemolysis, thrombosis and blood trauma in a clinical setting.","abstract_has_math":false,"creators":["Thatte, Suhas Madhusudan"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Dr. Gerald E. Miller"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:15:58Z","subjects":["Continuous blood pump","PIV","LVAD","Heart Assist Device","MDCP","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarscompass.vcu.edu/etd_retro/107","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarscompass.vcu.edu/etd_retro/107","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd_retro-1106","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Gerald E. Miller"]},{"key":"dc:creator","label":"Author","values":["Thatte, Suhas Madhusudan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-12-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Continuous blood pump","PIV","LVAD","Heart Assist Device","MDCP","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd_retro/107"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro and animal trials are conducted to study the flow fields in artificial ventricles to avoid hemolysis and thrombosis but the effects of flow fields corresponding to the angle of LVAD insertion into the aorta are often neglected. This experiment uses 30, 60 and 90 degree glass models to signify different angles of the surgical end to side anastomosis. Particle Image Velocimetry is used to study the flow fields at the interface and determine optimum angle amongst the three to avoid blood trauma. Use of a 30 degree glass interface minimizes stagnation zone, recirculation patterns, flow reversal, high shear region and other flow irregularities which may lead to reduced hemolysis, thrombosis and blood trauma in a clinical setting."]},{"key":"dc:description.note","label":"Dc Description Note","values":["Part of Retrospective ETD Collection, restricted to VCU only."]},{"key":"dc:title","label":"Title","values":["In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta."]}]}],"canonical_facts":{"dc:contributor":["Dr. Gerald E. Miller"],"dc:creator":["Thatte, Suhas Madhusudan"],"dc:date.available":["2024-12-09T08:00:00Z"],"dc:date.created":["2006-01-01T08:00:00Z"],"dc:description.abstract":["Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro and animal trials are conducted to study the flow fields in artificial ventricles to avoid hemolysis and thrombosis but the effects of flow fields corresponding to the angle of LVAD insertion into the aorta are often neglected. This experiment uses 30, 60 and 90 degree glass models to signify different angles of the surgical end to side anastomosis. Particle Image Velocimetry is used to study the flow fields at the interface and determine optimum angle amongst the three to avoid blood trauma. Use of a 30 degree glass interface minimizes stagnation zone, recirculation patterns, flow reversal, high shear region and other flow irregularities which may lead to reduced hemolysis, thrombosis and blood trauma in a clinical setting."],"dc:description.note":["Part of Retrospective ETD Collection, restricted to VCU only."],"dc:identifier":["https://scholarscompass.vcu.edu/etd_retro/107"],"dc:rights":["© The Author"],"dc:subject":["Continuous blood pump","PIV","LVAD","Heart Assist Device","MDCP","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta."],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:15:58Z"}