{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd_retro-1110"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd_retro-1110","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Potential for the Stimulation of Enodthelial Nitric Oxide Synthase Through the Use of Low Frequency Sound","abstract":"This study examines the possibility of the use of low frequency sound in the stimulation of Endothelial Nitric Oxide Synthase (eNOS), an enzyme which regulates the synthesis of NO from the amino acid L-arginine. To test this hypothesis, oximetry was used to measure changes in hemoglobin saturation in a subject exposed to a 45Hz signal, and accelerometers were used to monitor attenuation of two source frequencies (45Hz and 8Hz) across 5 subjects at varying source transducer locations. The data from the oximetry monitoring was only suggestive, but its interpretation is encouraging for future avenues of study. Examining the attenuation of the applied frequencies showed, as expected, did not show a strong dependence on the height or weight of the subject, with little transmission loss throughout the body. These data establish the firm groundwork for future experimentation to reduce the methodology into a clinically feasible medical device","abstract_html":"This study examines the possibility of the use of low frequency sound in the stimulation of Endothelial Nitric Oxide Synthase (eNOS), an enzyme which regulates the synthesis of NO from the amino acid L-arginine. To test this hypothesis, oximetry was used to measure changes in hemoglobin saturation in a subject exposed to a 45Hz signal, and accelerometers were used to monitor attenuation of two source frequencies (45Hz and 8Hz) across 5 subjects at varying source transducer locations. The data from the oximetry monitoring was only suggestive, but its interpretation is encouraging for future avenues of study. Examining the attenuation of the applied frequencies showed, as expected, did not show a strong dependence on the height or weight of the subject, with little transmission loss throughout the body. These data establish the firm groundwork for future experimentation to reduce the methodology into a clinically feasible medical device","abstract_has_math":false,"creators":["May, Brandon H."],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Dr. Martin L. Lenhardt"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-01-01T08:00:00Z","date_published":"2006-01-01T08:00:00Z","updated_at":"2026-11-27T10:08:15Z","subjects":["eNOS","NO","bioacoustics","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd_retro/111"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd_retro/111","href":"https://scholarscompass.vcu.edu/etd_retro/111","code":true}]},{"key":"dc:identifier.handle","label":"Dc Identifier Handle","values":["10156/1236"],"render_values":[{"text":"10156/1236","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10156/1236","outbound_label":"Handle","outbound_source":"dc:identifier.handle","record_url":"https://hdl.handle.net/10156/1236","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.handle","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avcu%3Aoai%3Ascholarscompass.vcu.edu%3Aetd_retro-1110","prefix":"oai_dc"},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=qualified-dublin-core&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd_retro-1110","prefix":"qualified-dublin-core"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Martin L. Lenhardt"]},{"key":"dc:creator","label":"Author","values":["May, Brandon H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-12-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-01-01T08:00:00Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008-06-13T07:00:00Z"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["VCU University Archives","VCU Theses and Dissertations"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["eNOS","NO","bioacoustics","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd_retro/111"]},{"key":"dc:identifier.handle","label":"Dc Identifier Handle","values":["10156/1236"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study examines the possibility of the use of low frequency sound in the stimulation of Endothelial Nitric Oxide Synthase (eNOS), an enzyme which regulates the synthesis of NO from the amino acid L-arginine. To test this hypothesis, oximetry was used to measure changes in hemoglobin saturation in a subject exposed to a 45Hz signal, and accelerometers were used to monitor attenuation of two source frequencies (45Hz and 8Hz) across 5 subjects at varying source transducer locations. The data from the oximetry monitoring was only suggestive, but its interpretation is encouraging for future avenues of study. Examining the attenuation of the applied frequencies showed, as expected, did not show a strong dependence on the height or weight of the subject, with little transmission loss throughout the body. These data establish the firm groundwork for future experimentation to reduce the methodology into a clinically feasible medical device"]},{"key":"dc:description.note","label":"Dc Description Note","values":["Part of Retrospective ETD Collection, restricted to VCU only."]},{"key":"dc:title","label":"Title","values":["Potential for the Stimulation of Enodthelial Nitric Oxide Synthase Through the Use of Low Frequency Sound"]}]}],"canonical_facts":{"dc:contributor":["Dr. Martin L. Lenhardt"],"dc:creator":["May, Brandon H."],"dc:date.available":["2024-12-09T08:00:00Z"],"dc:date.created":["2006-01-01T08:00:00Z"],"dc:date.submitted":["2008-06-13T07:00:00Z"],"dc:description.abstract":["This study examines the possibility of the use of low frequency sound in the stimulation of Endothelial Nitric Oxide Synthase (eNOS), an enzyme which regulates the synthesis of NO from the amino acid L-arginine. To test this hypothesis, oximetry was used to measure changes in hemoglobin saturation in a subject exposed to a 45Hz signal, and accelerometers were used to monitor attenuation of two source frequencies (45Hz and 8Hz) across 5 subjects at varying source transducer locations. The data from the oximetry monitoring was only suggestive, but its interpretation is encouraging for future avenues of study. Examining the attenuation of the applied frequencies showed, as expected, did not show a strong dependence on the height or weight of the subject, with little transmission loss throughout the body. These data establish the firm groundwork for future experimentation to reduce the methodology into a clinically feasible medical device"],"dc:description.note":["Part of Retrospective ETD Collection, restricted to VCU only."],"dc:identifier":["https://scholarscompass.vcu.edu/etd_retro/111"],"dc:identifier.handle":["10156/1236"],"dc:relation.ispartof":["VCU University Archives","VCU Theses and Dissertations"],"dc:rights":["© The Author"],"dc:subject":["eNOS","NO","bioacoustics","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["Potential for the Stimulation of Enodthelial Nitric Oxide Synthase Through the Use of Low Frequency Sound"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-27T10:08:15Z"}