{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:107205482"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:107205482","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Detection of ionizing radiation-induced optical nonlinearities in a gagg crystal /","abstract":"Scintillator-based ionizing radiation (IR) detectors offer low time resolution and have to be close to the radiation source, where electromagnetic pulse (EMP) impact on electronics can affect the signal or degrade the equipment. Thus, a new optical-based class of IR detectors that offer an improved time resolution and reduce device degradation are under research. These detectors rely on measuring changes of optical nonlinearities, which are usually minimal and difficult to register. Thus, high sensitivity is of the essence. In this work, we investigate two gadolinium aluminium gallium garnet (GAGG: Ce, Mg) based structures as remote ionizing radiation detectors in a multi-pass pulsed pump continuous-wave probe setup. The multi-pass principle relies on obtaining multiple probe beam passes within the excited region, thus maximizing sensitivity. Modelling a ray-tracing Python script for the two designed structures – a gold-coated cube and a dielectric-coated wedged slab – provided a complementary source for our experimental procedures, enabling an effective and time-saving investigation. The concept of a multi-pass pump-probe configuration has been successfully implemented – in the Au coated cube, a low induced free-carrier concentration of 1.6×10^{15} cm^{&#8722;3} at a 1% differential signal under a 266 nm 4.2 µJ excitation pulse (&#8764;0.17 mJ/cm^2) was detected. The back-reflection configuration was successfully achieved using the dielectric-coated wedged sample that offers our highest sensitivity, and the lowest detectable signal is to be reevaluated in future work.","abstract_html":"Scintillator-based ionizing radiation (IR) detectors offer low time resolution and have to be close to the radiation source, where electromagnetic pulse (EMP) impact on electronics can affect the signal or degrade the equipment. Thus, a new optical-based class of IR detectors that offer an improved time resolution and reduce device degradation are under research. These detectors rely on measuring changes of optical nonlinearities, which are usually minimal and difficult to register. Thus, high sensitivity is of the essence. In this work, we investigate two gadolinium aluminium gallium garnet (GAGG: Ce, Mg) based structures as remote ionizing radiation detectors in a multi-pass pulsed pump continuous-wave probe setup. The multi-pass principle relies on obtaining multiple probe beam passes within the excited region, thus maximizing sensitivity. Modelling a ray-tracing Python script for the two designed structures – a gold-coated cube and a dielectric-coated wedged slab – provided a complementary source for our experimental procedures, enabling an effective and time-saving investigation. The concept of a multi-pass pump-probe configuration has been successfully implemented – in the Au coated cube, a low induced free-carrier concentration of 1.6×10^{15} cm^{&amp;#8722;3} at a 1% differential signal under a 266 nm 4.2 µJ excitation pulse (&amp;#8764;0.17 mJ/cm^2) was detected. The back-reflection configuration was successfully achieved using the dielectric-coated wedged sample that offers our highest sensitivity, and the lowest detectable signal is to be reevaluated in future work.","abstract_has_math":false,"creators":["Alsamsam, Mohammad Nour,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Nomeika, Kazimieras"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T10:10:59Z","subjects":["GAGG, multi-pass, Free Carrier Absorption, Ionizing radiation detection, pump-probe"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD107205482&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD107205482&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A107205482","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nomeika, Kazimieras"]},{"key":"dc:creator","label":"Author","values":["Alsamsam, Mohammad Nour,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:107205482/107205482.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["GAGG, multi-pass, Free Carrier Absorption, Ionizing radiation detection, pump-probe"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD107205482&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Scintillator-based ionizing radiation (IR) detectors offer low time resolution and have to be close to the radiation source, where electromagnetic pulse (EMP) impact on electronics can affect the signal or degrade the equipment. Thus, a new optical-based class of IR detectors that offer an improved time resolution and reduce device degradation are under research. These detectors rely on measuring changes of optical nonlinearities, which are usually minimal and difficult to register. Thus, high sensitivity is of the essence. In this work, we investigate two gadolinium aluminium gallium garnet (GAGG: Ce, Mg) based structures as remote ionizing radiation detectors in a multi-pass pulsed pump continuous-wave probe setup. The multi-pass principle relies on obtaining multiple probe beam passes within the excited region, thus maximizing sensitivity. Modelling a ray-tracing Python script for the two designed structures – a gold-coated cube and a dielectric-coated wedged slab – provided a complementary source for our experimental procedures, enabling an effective and time-saving investigation. The concept of a multi-pass pump-probe configuration has been successfully implemented – in the Au coated cube, a low induced free-carrier concentration of 1.6×10^{15} cm^{&#8722;3} at a 1% differential signal under a 266 nm 4.2 µJ excitation pulse (&#8764;0.17 mJ/cm^2) was detected. The back-reflection configuration was successfully achieved using the dielectric-coated wedged sample that offers our highest sensitivity, and the lowest detectable signal is to be reevaluated in future work."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Detection of ionizing radiation-induced optical nonlinearities in a gagg crystal /","Jonizuojančios spinduliuotės sukeltų optinių netiesiškumų detektavimas GAGG kristale."]}]}],"canonical_facts":{"dc:contributor":["Nomeika, Kazimieras"],"dc:creator":["Alsamsam, Mohammad Nour,"],"dc:date":["2021"],"dc:description":["Scintillator-based ionizing radiation (IR) detectors offer low time resolution and have to be close to the radiation source, where electromagnetic pulse (EMP) impact on electronics can affect the signal or degrade the equipment. Thus, a new optical-based class of IR detectors that offer an improved time resolution and reduce device degradation are under research. These detectors rely on measuring changes of optical nonlinearities, which are usually minimal and difficult to register. Thus, high sensitivity is of the essence. In this work, we investigate two gadolinium aluminium gallium garnet (GAGG: Ce, Mg) based structures as remote ionizing radiation detectors in a multi-pass pulsed pump continuous-wave probe setup. The multi-pass principle relies on obtaining multiple probe beam passes within the excited region, thus maximizing sensitivity. Modelling a ray-tracing Python script for the two designed structures – a gold-coated cube and a dielectric-coated wedged slab – provided a complementary source for our experimental procedures, enabling an effective and time-saving investigation. The concept of a multi-pass pump-probe configuration has been successfully implemented – in the Au coated cube, a low induced free-carrier concentration of 1.6×10^{15} cm^{&#8722;3} at a 1% differential signal under a 266 nm 4.2 µJ excitation pulse (&#8764;0.17 mJ/cm^2) was detected. The back-reflection configuration was successfully achieved using the dielectric-coated wedged sample that offers our highest sensitivity, and the lowest detectable signal is to be reevaluated in future work."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD107205482&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:107205482/107205482.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["GAGG, multi-pass, Free Carrier Absorption, Ionizing radiation detection, pump-probe"],"dc:title":["Detection of ionizing radiation-induced optical nonlinearities in a gagg crystal /","Jonizuojančios spinduliuotės sukeltų optinių netiesiškumų detektavimas GAGG kristale."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:10:59Z"}