{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:1839585"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:1839585","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Žvilgsnio registravimas panaudojant vyzdžio centrą ir kelis ragenos atšvaitus /","abstract":"Human eye movements is widely-researched and using in practice. Scientists from different fields research individual eye movement parameters. The aim is - to investigate the eye movement measuring system with multiple light sources gaze direction detection errors. In work are described human eye movements types, eye movement measurement systems guide, the pupil center and corneal reflection mathematical description. Designed eye movement’s measurement system description. Paper describes the research methodology of eye movement measurement system errors to be examined, designed to study the system and get results. The final result - a software and equipment to measure eye movements with a few IR light sources, and examined the eye movement measurement system view point of error detection.","abstract_html":"Human eye movements is widely-researched and using in practice. Scientists from different fields research individual eye movement parameters. The aim is - to investigate the eye movement measuring system with multiple light sources gaze direction detection errors. In work are described human eye movements types, eye movement measurement systems guide, the pupil center and corneal reflection mathematical description. Designed eye movement’s measurement system description. Paper describes the research methodology of eye movement measurement system errors to be examined, designed to study the system and get results. The final result - a software and equipment to measure eye movements with a few IR light sources, and examined the eye movement measurement system view point of error detection.","abstract_has_math":false,"creators":["Grigas, Julius,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Ramanauskas, Nrijus"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-19T10:00:07Z","subjects":["eye ; geze tracking ; eye tracking system"],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD1839585&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD1839585&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A1839585","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ramanauskas, Nrijus"]},{"key":"dc:creator","label":"Author","values":["Grigas, Julius,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:1839585/1839585.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/masterThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["eye ; geze tracking ; eye tracking system"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD1839585&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Human eye movements is widely-researched and using in practice. Scientists from different fields research individual eye movement parameters. The aim is - to investigate the eye movement measuring system with multiple light sources gaze direction detection errors. In work are described human eye movements types, eye movement measurement systems guide, the pupil center and corneal reflection mathematical description. Designed eye movement’s measurement system description. Paper describes the research methodology of eye movement measurement system errors to be examined, designed to study the system and get results. The final result - a software and equipment to measure eye movements with a few IR light sources, and examined the eye movement measurement system view point of error detection."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Žvilgsnio registravimas panaudojant vyzdžio centrą ir kelis ragenos atšvaitus /","Eye-Gaze Tracking Using Pupil Center and Multiple Glints."]}]}],"canonical_facts":{"dc:contributor":["Ramanauskas, Nrijus"],"dc:creator":["Grigas, Julius,"],"dc:date":["2011"],"dc:description":["Human eye movements is widely-researched and using in practice. Scientists from different fields research individual eye movement parameters. The aim is - to investigate the eye movement measuring system with multiple light sources gaze direction detection errors. In work are described human eye movements types, eye movement measurement systems guide, the pupil center and corneal reflection mathematical description. Designed eye movement’s measurement system description. Paper describes the research methodology of eye movement measurement system errors to be examined, designed to study the system and get results. The final result - a software and equipment to measure eye movements with a few IR light sources, and examined the eye movement measurement system view point of error detection."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD1839585&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:1839585/1839585.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["eye ; geze tracking ; eye tracking system"],"dc:title":["Žvilgsnio registravimas panaudojant vyzdžio centrą ir kelis ragenos atšvaitus /","Eye-Gaze Tracking Using Pupil Center and Multiple Glints."],"dc:type":["info:eu-repo/semantics/masterThesis"]},"updated_at":"2026-11-19T10:00:07Z"}