{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:184585821"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:184585821","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Enhancing gas chromatographic analysis: a novel cryo-enrichment module for GC analysis /","abstract":"In this PhD thesis, the application of cryo-enrichment in gas chromatography is explored. It is a technique designed to enhance the separation and detection of volatile compounds in complex mixtures. By lowering the temperature of the chromatographic column to extremely low levels, this method reduces the volatility of compounds, leading to their efficient condensation onto the column's stationary phase. The primary focus of the thesis is the development of a custom cryo-enrichment module to improve system efficiency and sensitivity. Multiple prototypes were constructed and evaluated, yielding significant improvements for gas chromatography. Notably, peak resolution increased up to 2.2 times, and the most optimal outcomes were achieved when cooling 95 cm of the column length, resulting in a 20-fold sensitivity boost. However, limitations were observed, particularly related to the analyte working range, where some compounds were not retained adequately due to insufficient cooling while others were retained excessively due to inadequate heating. The module was tested in various applications, such as method calibration, impurities analysis, fungicide analysis, and measuring terpenes in Cannabis Sativa biomass. This research shows that cryo-enrichment in gas chromatography holds potential for improving analysis, but it also recognizes the necessity for more refinement and practical application.","abstract_html":"In this PhD thesis, the application of cryo-enrichment in gas chromatography is explored. It is a technique designed to enhance the separation and detection of volatile compounds in complex mixtures. By lowering the temperature of the chromatographic column to extremely low levels, this method reduces the volatility of compounds, leading to their efficient condensation onto the column&#x27;s stationary phase. The primary focus of the thesis is the development of a custom cryo-enrichment module to improve system efficiency and sensitivity. Multiple prototypes were constructed and evaluated, yielding significant improvements for gas chromatography. Notably, peak resolution increased up to 2.2 times, and the most optimal outcomes were achieved when cooling 95 cm of the column length, resulting in a 20-fold sensitivity boost. However, limitations were observed, particularly related to the analyte working range, where some compounds were not retained adequately due to insufficient cooling while others were retained excessively due to inadequate heating. The module was tested in various applications, such as method calibration, impurities analysis, fungicide analysis, and measuring terpenes in Cannabis Sativa biomass. This research shows that cryo-enrichment in gas chromatography holds potential for improving analysis, but it also recognizes the necessity for more refinement and practical application.","abstract_has_math":false,"creators":["Sadaunykas, Audrius,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Naujalis, Evaldas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T09:55:08Z","subjects":["gas chromatography ; cryo-enrichment ; terpenes"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD184585821&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD184585821&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A184585821","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Naujalis, Evaldas"]},{"key":"dc:creator","label":"Author","values":["Sadaunykas, Audrius,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["info:eu-repo/semantics/altIdentifier/doi/10.15388/vu.thesis.563","https://epublications.vu.lt/object/elaba:184585821/184585821.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/doctoralThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["gas chromatography ; cryo-enrichment ; terpenes"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD184585821&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this PhD thesis, the application of cryo-enrichment in gas chromatography is explored. It is a technique designed to enhance the separation and detection of volatile compounds in complex mixtures. By lowering the temperature of the chromatographic column to extremely low levels, this method reduces the volatility of compounds, leading to their efficient condensation onto the column's stationary phase. The primary focus of the thesis is the development of a custom cryo-enrichment module to improve system efficiency and sensitivity. Multiple prototypes were constructed and evaluated, yielding significant improvements for gas chromatography. Notably, peak resolution increased up to 2.2 times, and the most optimal outcomes were achieved when cooling 95 cm of the column length, resulting in a 20-fold sensitivity boost. However, limitations were observed, particularly related to the analyte working range, where some compounds were not retained adequately due to insufficient cooling while others were retained excessively due to inadequate heating. The module was tested in various applications, such as method calibration, impurities analysis, fungicide analysis, and measuring terpenes in Cannabis Sativa biomass. This research shows that cryo-enrichment in gas chromatography holds potential for improving analysis, but it also recognizes the necessity for more refinement and practical application."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Enhancing gas chromatographic analysis: a novel cryo-enrichment module for GC analysis /","Dujų chromatografinės analizės tobulinimas: inovatyvus krio-koncentravimo modulis GC analizei."]}]}],"canonical_facts":{"dc:contributor":["Naujalis, Evaldas"],"dc:creator":["Sadaunykas, Audrius,"],"dc:date":["2023"],"dc:description":["In this PhD thesis, the application of cryo-enrichment in gas chromatography is explored. It is a technique designed to enhance the separation and detection of volatile compounds in complex mixtures. By lowering the temperature of the chromatographic column to extremely low levels, this method reduces the volatility of compounds, leading to their efficient condensation onto the column's stationary phase. The primary focus of the thesis is the development of a custom cryo-enrichment module to improve system efficiency and sensitivity. Multiple prototypes were constructed and evaluated, yielding significant improvements for gas chromatography. Notably, peak resolution increased up to 2.2 times, and the most optimal outcomes were achieved when cooling 95 cm of the column length, resulting in a 20-fold sensitivity boost. However, limitations were observed, particularly related to the analyte working range, where some compounds were not retained adequately due to insufficient cooling while others were retained excessively due to inadequate heating. The module was tested in various applications, such as method calibration, impurities analysis, fungicide analysis, and measuring terpenes in Cannabis Sativa biomass. This research shows that cryo-enrichment in gas chromatography holds potential for improving analysis, but it also recognizes the necessity for more refinement and practical application."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD184585821&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["info:eu-repo/semantics/altIdentifier/doi/10.15388/vu.thesis.563","https://epublications.vu.lt/object/elaba:184585821/184585821.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["gas chromatography ; cryo-enrichment ; terpenes"],"dc:title":["Enhancing gas chromatographic analysis: a novel cryo-enrichment module for GC analysis /","Dujų chromatografinės analizės tobulinimas: inovatyvus krio-koncentravimo modulis GC analizei."],"dc:type":["info:eu-repo/semantics/doctoralThesis"]},"updated_at":"2026-11-19T09:55:08Z"}