{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192833712"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192833712","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Oftalmologinių lazerių pagrindinių parametrų charakterizavimo ir optimizavimo tyrimas /","abstract":"It is widely known that lasers are becoming increasingly important these days. Now there are a variety of different types of lasers, and they are used in industry, in the military sphere and in medicine. One of the most popular spheres of medicine, where lasers are used for – ophthalmology. In this paper I am going to compare two similar ophthalmology lasers with different crystals of Pockels cell. In the theoretical part is written about working principle of laser, their main parts, what is femtosecond laser, how ophthalmology laser is different from other lasers. Also, there are described the main parameters of laser beam, type of quality modulation and Pockels cell. In the research part, as mentioned before, two ophthalmology lasers were tested – one with Rubidium Titanyl Phosphate (RTP) modulator, second with Beta Barium Borate (BBO) modulator. There were made beam profile, M^2, power and energy dependence of coupling current tests. Also, there were a few stability tests and lasers with different modulators dependence of RA current of time. In this part are described reasons, why lasers with RTP modulator are no longer best choice for ophthalmology, why the BBO modulator laser was made and what different between these lasers. After tests, there are compared the results of both lasers. The beam quality of the laser with BBO modulator is better than laser with RTP modulator. It was affected by better cooling of BBO laser, because this system was little bit changed in this area. Energy and power dependence of coupling current are similar for both lasers, both works properly. Also, RA current of laser with BBO modulator was more stable than laser with RTP modulator, what was affected by change of Pockels cell crystal. In BBO crystal, at the testing time, electrochromic effect did not occur. However, laser with BBO modulator has worse stability than laser with RTP modulator. These deteriorations may have resulted from changes of resonator of amplifier, because in the laser with BBO modulator Pockels cell, which was connected to the amplifier, was replaced and there was higher voltage. Overall, laser with BBO modulator has better beam quality, but worse beam stability. However, in laser with BBO crystal, fault of Pockels cell crystal electrochromic effect was cleared.","abstract_html":"It is widely known that lasers are becoming increasingly important these days. Now there are a variety of different types of lasers, and they are used in industry, in the military sphere and in medicine. One of the most popular spheres of medicine, where lasers are used for – ophthalmology. In this paper I am going to compare two similar ophthalmology lasers with different crystals of Pockels cell. In the theoretical part is written about working principle of laser, their main parts, what is femtosecond laser, how ophthalmology laser is different from other lasers. Also, there are described the main parameters of laser beam, type of quality modulation and Pockels cell. In the research part, as mentioned before, two ophthalmology lasers were tested – one with Rubidium Titanyl Phosphate (RTP) modulator, second with Beta Barium Borate (BBO) modulator. There were made beam profile, M^2, power and energy dependence of coupling current tests. Also, there were a few stability tests and lasers with different modulators dependence of RA current of time. In this part are described reasons, why lasers with RTP modulator are no longer best choice for ophthalmology, why the BBO modulator laser was made and what different between these lasers. After tests, there are compared the results of both lasers. The beam quality of the laser with BBO modulator is better than laser with RTP modulator. It was affected by better cooling of BBO laser, because this system was little bit changed in this area. Energy and power dependence of coupling current are similar for both lasers, both works properly. Also, RA current of laser with BBO modulator was more stable than laser with RTP modulator, what was affected by change of Pockels cell crystal. In BBO crystal, at the testing time, electrochromic effect did not occur. However, laser with BBO modulator has worse stability than laser with RTP modulator. These deteriorations may have resulted from changes of resonator of amplifier, because in the laser with BBO modulator Pockels cell, which was connected to the amplifier, was replaced and there was higher voltage. Overall, laser with BBO modulator has better beam quality, but worse beam stability. However, in laser with BBO crystal, fault of Pockels cell crystal electrochromic effect was cleared.","abstract_has_math":false,"creators":["Beržinskaitė, Gabija,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T09:55:35Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192833712&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192833712&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192833712","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Beržinskaitė, Gabija,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192833712/192833712.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192833712&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["It is widely known that lasers are becoming increasingly important these days. Now there are a variety of different types of lasers, and they are used in industry, in the military sphere and in medicine. One of the most popular spheres of medicine, where lasers are used for – ophthalmology. In this paper I am going to compare two similar ophthalmology lasers with different crystals of Pockels cell. In the theoretical part is written about working principle of laser, their main parts, what is femtosecond laser, how ophthalmology laser is different from other lasers. Also, there are described the main parameters of laser beam, type of quality modulation and Pockels cell. In the research part, as mentioned before, two ophthalmology lasers were tested – one with Rubidium Titanyl Phosphate (RTP) modulator, second with Beta Barium Borate (BBO) modulator. There were made beam profile, M^2, power and energy dependence of coupling current tests. Also, there were a few stability tests and lasers with different modulators dependence of RA current of time. In this part are described reasons, why lasers with RTP modulator are no longer best choice for ophthalmology, why the BBO modulator laser was made and what different between these lasers. After tests, there are compared the results of both lasers. The beam quality of the laser with BBO modulator is better than laser with RTP modulator. It was affected by better cooling of BBO laser, because this system was little bit changed in this area. Energy and power dependence of coupling current are similar for both lasers, both works properly. Also, RA current of laser with BBO modulator was more stable than laser with RTP modulator, what was affected by change of Pockels cell crystal. In BBO crystal, at the testing time, electrochromic effect did not occur. However, laser with BBO modulator has worse stability than laser with RTP modulator. These deteriorations may have resulted from changes of resonator of amplifier, because in the laser with BBO modulator Pockels cell, which was connected to the amplifier, was replaced and there was higher voltage. Overall, laser with BBO modulator has better beam quality, but worse beam stability. However, in laser with BBO crystal, fault of Pockels cell crystal electrochromic effect was cleared."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Oftalmologinių lazerių pagrindinių parametrų charakterizavimo ir optimizavimo tyrimas /","Study of characterization and optimization of the main parameters of ophthalmic lasers."]}]}],"canonical_facts":{"dc:creator":["Beržinskaitė, Gabija,"],"dc:date":["2023"],"dc:description":["It is widely known that lasers are becoming increasingly important these days. Now there are a variety of different types of lasers, and they are used in industry, in the military sphere and in medicine. One of the most popular spheres of medicine, where lasers are used for – ophthalmology. In this paper I am going to compare two similar ophthalmology lasers with different crystals of Pockels cell. In the theoretical part is written about working principle of laser, their main parts, what is femtosecond laser, how ophthalmology laser is different from other lasers. Also, there are described the main parameters of laser beam, type of quality modulation and Pockels cell. In the research part, as mentioned before, two ophthalmology lasers were tested – one with Rubidium Titanyl Phosphate (RTP) modulator, second with Beta Barium Borate (BBO) modulator. There were made beam profile, M^2, power and energy dependence of coupling current tests. Also, there were a few stability tests and lasers with different modulators dependence of RA current of time. In this part are described reasons, why lasers with RTP modulator are no longer best choice for ophthalmology, why the BBO modulator laser was made and what different between these lasers. After tests, there are compared the results of both lasers. The beam quality of the laser with BBO modulator is better than laser with RTP modulator. It was affected by better cooling of BBO laser, because this system was little bit changed in this area. Energy and power dependence of coupling current are similar for both lasers, both works properly. Also, RA current of laser with BBO modulator was more stable than laser with RTP modulator, what was affected by change of Pockels cell crystal. In BBO crystal, at the testing time, electrochromic effect did not occur. However, laser with BBO modulator has worse stability than laser with RTP modulator. These deteriorations may have resulted from changes of resonator of amplifier, because in the laser with BBO modulator Pockels cell, which was connected to the amplifier, was replaced and there was higher voltage. Overall, laser with BBO modulator has better beam quality, but worse beam stability. However, in laser with BBO crystal, fault of Pockels cell crystal electrochromic effect was cleared."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192833712&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192833712/192833712.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Oftalmologinių lazerių pagrindinių parametrų charakterizavimo ir optimizavimo tyrimas /","Study of characterization and optimization of the main parameters of ophthalmic lasers."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:55:35Z"}