{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192842191"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192842191","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"ZnO nanostruktūrų taikymas elektrocheminiame jutiklyje specifinių antikūnų prieš SARS-CoV-2 viruso nukleokapsidės baltymą nustatymui /","abstract":"On March 11, 2020, the World Health Organization (WHO) declared the coronavirus disease 2019 (COVID-19), caused by SARS-coronavirus 2 (SARS-CoV-2), pandemic. To prevent the spread of the virus, vaccines have been developed. The developed vaccines create an immune response to the spike protein of SARS-CoV-2. Due to that immune response, the nucleocapsid protein became an important indication of the disease. The use of ZnO nanostructures in electrochemical sensors is increasing since ZnO nanostructures are non-toxic to humans and environment, have a high surface-to-volume ratio, are cheap and easily available. The aim of this study is to check the suitability of ZnO nanostructures for the development of the electrochemical sensor for antibodies against the nucleocapsid protein of the SARS-CoV-2 virus. The study found that ZnO tetrapods (ZnO TPs) are more suitable for electrochemical sensor meant for detection of specific antibodies, against SARS-CoV-2 nucleocapsid (N) protein, compared to ZnO nanorods. From the SEM pictures taken of ZnO TPs, it was determined that the length of tetrapod legs were 3.29 ± 0.28 µm. In addition, modification of the electrode surface with ZnO tetrapods allows to increase the electroactive surface area from 0.0591 to 0.0702 cm2. When protein adsorption takes place on the graphite electrode surface modified with 3 &#956;l of 0.5 mg·ml-1 ZnO TP + 0.05 % Nafion solution, the optimal duration (30 min.) and concentration (300 nmol·l-1) of SARS-CoV-2 nucleocapsid (N) protein immobilization on the electrode surface was determined. After modifying the electrode with this method, a linear dependence was observed in the determination of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2 in the concentration range from 0.1 to 1 nmol·l-1. The selected ZnO TPs can be used to develop an electrochemical sensor for the detection of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2.","abstract_html":"On March 11, 2020, the World Health Organization (WHO) declared the coronavirus disease 2019 (COVID-19), caused by SARS-coronavirus 2 (SARS-CoV-2), pandemic. To prevent the spread of the virus, vaccines have been developed. The developed vaccines create an immune response to the spike protein of SARS-CoV-2. Due to that immune response, the nucleocapsid protein became an important indication of the disease. The use of ZnO nanostructures in electrochemical sensors is increasing since ZnO nanostructures are non-toxic to humans and environment, have a high surface-to-volume ratio, are cheap and easily available. The aim of this study is to check the suitability of ZnO nanostructures for the development of the electrochemical sensor for antibodies against the nucleocapsid protein of the SARS-CoV-2 virus. The study found that ZnO tetrapods (ZnO TPs) are more suitable for electrochemical sensor meant for detection of specific antibodies, against SARS-CoV-2 nucleocapsid (N) protein, compared to ZnO nanorods. From the SEM pictures taken of ZnO TPs, it was determined that the length of tetrapod legs were 3.29 ± 0.28 µm. In addition, modification of the electrode surface with ZnO tetrapods allows to increase the electroactive surface area from 0.0591 to 0.0702 cm2. When protein adsorption takes place on the graphite electrode surface modified with 3 &amp;#956;l of 0.5 mg·ml-1 ZnO TP + 0.05 % Nafion solution, the optimal duration (30 min.) and concentration (300 nmol·l-1) of SARS-CoV-2 nucleocapsid (N) protein immobilization on the electrode surface was determined. After modifying the electrode with this method, a linear dependence was observed in the determination of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2 in the concentration range from 0.1 to 1 nmol·l-1. The selected ZnO TPs can be used to develop an electrochemical sensor for the detection of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2.","abstract_has_math":false,"creators":["Banevičiūtė, Egita,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T09:55:49Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192842191&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192842191&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192842191","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Banevičiūtė, Egita,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192842191/192842191.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192842191&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["On March 11, 2020, the World Health Organization (WHO) declared the coronavirus disease 2019 (COVID-19), caused by SARS-coronavirus 2 (SARS-CoV-2), pandemic. To prevent the spread of the virus, vaccines have been developed. The developed vaccines create an immune response to the spike protein of SARS-CoV-2. Due to that immune response, the nucleocapsid protein became an important indication of the disease. The use of ZnO nanostructures in electrochemical sensors is increasing since ZnO nanostructures are non-toxic to humans and environment, have a high surface-to-volume ratio, are cheap and easily available. The aim of this study is to check the suitability of ZnO nanostructures for the development of the electrochemical sensor for antibodies against the nucleocapsid protein of the SARS-CoV-2 virus. The study found that ZnO tetrapods (ZnO TPs) are more suitable for electrochemical sensor meant for detection of specific antibodies, against SARS-CoV-2 nucleocapsid (N) protein, compared to ZnO nanorods. From the SEM pictures taken of ZnO TPs, it was determined that the length of tetrapod legs were 3.29 ± 0.28 µm. In addition, modification of the electrode surface with ZnO tetrapods allows to increase the electroactive surface area from 0.0591 to 0.0702 cm2. When protein adsorption takes place on the graphite electrode surface modified with 3 &#956;l of 0.5 mg·ml-1 ZnO TP + 0.05 % Nafion solution, the optimal duration (30 min.) and concentration (300 nmol·l-1) of SARS-CoV-2 nucleocapsid (N) protein immobilization on the electrode surface was determined. After modifying the electrode with this method, a linear dependence was observed in the determination of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2 in the concentration range from 0.1 to 1 nmol·l-1. The selected ZnO TPs can be used to develop an electrochemical sensor for the detection of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["ZnO nanostruktūrų taikymas elektrocheminiame jutiklyje specifinių antikūnų prieš SARS-CoV-2 viruso nukleokapsidės baltymą nustatymui /","Application of zno nanostructures in an electrochemical sensor for the detection of specific antibodies against sars-cov-2 virus nucleocapsid protein."]}]}],"canonical_facts":{"dc:creator":["Banevičiūtė, Egita,"],"dc:date":["2023"],"dc:description":["On March 11, 2020, the World Health Organization (WHO) declared the coronavirus disease 2019 (COVID-19), caused by SARS-coronavirus 2 (SARS-CoV-2), pandemic. To prevent the spread of the virus, vaccines have been developed. The developed vaccines create an immune response to the spike protein of SARS-CoV-2. Due to that immune response, the nucleocapsid protein became an important indication of the disease. The use of ZnO nanostructures in electrochemical sensors is increasing since ZnO nanostructures are non-toxic to humans and environment, have a high surface-to-volume ratio, are cheap and easily available. The aim of this study is to check the suitability of ZnO nanostructures for the development of the electrochemical sensor for antibodies against the nucleocapsid protein of the SARS-CoV-2 virus. The study found that ZnO tetrapods (ZnO TPs) are more suitable for electrochemical sensor meant for detection of specific antibodies, against SARS-CoV-2 nucleocapsid (N) protein, compared to ZnO nanorods. From the SEM pictures taken of ZnO TPs, it was determined that the length of tetrapod legs were 3.29 ± 0.28 µm. In addition, modification of the electrode surface with ZnO tetrapods allows to increase the electroactive surface area from 0.0591 to 0.0702 cm2. When protein adsorption takes place on the graphite electrode surface modified with 3 &#956;l of 0.5 mg·ml-1 ZnO TP + 0.05 % Nafion solution, the optimal duration (30 min.) and concentration (300 nmol·l-1) of SARS-CoV-2 nucleocapsid (N) protein immobilization on the electrode surface was determined. After modifying the electrode with this method, a linear dependence was observed in the determination of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2 in the concentration range from 0.1 to 1 nmol·l-1. The selected ZnO TPs can be used to develop an electrochemical sensor for the detection of specific antibodies against the nucleocapsid (N) protein of SARS-CoV-2."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192842191&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192842191/192842191.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["ZnO nanostruktūrų taikymas elektrocheminiame jutiklyje specifinių antikūnų prieš SARS-CoV-2 viruso nukleokapsidės baltymą nustatymui /","Application of zno nanostructures in an electrochemical sensor for the detection of specific antibodies against sars-cov-2 virus nucleocapsid protein."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:55:49Z"}