{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192970691"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192970691","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Manufacturing of microfluidic micro- and nanoparticle separator via femtosecond laser /","abstract":"The constant growth of technologies introduced a possibility to scale-down complex laboratory equipment – lab-on-chip (LOC). These devices work in the volume range from nanoliters to milliliters, so they excel in fast reaction time and low consumption of reagents. This work shows the possibility of producing a LOC device, a macromolecule separator, by employing a hybrid fabrication technique, which is the combination of subtractive and additive techniques. The device was fabricated in three steps. First is the ablation of the microchannel system, which was done by using a femtosecond laser to induce minimal thermal effects. The second part, integration of macromolecule separator was completed by employing three-dimensional laser lithography. The macromolecule separator was integrated with the possibility to modify its pore size from 500 nm to 1000 nm and more. As for the last step, sealing was completed by using a direct thermal bonding technique. A plastic coverslip was melted on top of the LOC device to ensure a hermetic seal. The fabricated device was tested by flowing distilled water and methanol through it. In result, distilled water stopped flowing after first microfilter, due to small pore size (500 nm). Instead, a lower viscosity value fluid, methanol was used and it successfully traveled throughout the device. Different flow rates were observed in outlet 1 and 2, proving that the fluid is being distributed throughout all three outlets.","abstract_html":"The constant growth of technologies introduced a possibility to scale-down complex laboratory equipment – lab-on-chip (LOC). These devices work in the volume range from nanoliters to milliliters, so they excel in fast reaction time and low consumption of reagents. This work shows the possibility of producing a LOC device, a macromolecule separator, by employing a hybrid fabrication technique, which is the combination of subtractive and additive techniques. The device was fabricated in three steps. First is the ablation of the microchannel system, which was done by using a femtosecond laser to induce minimal thermal effects. The second part, integration of macromolecule separator was completed by employing three-dimensional laser lithography. The macromolecule separator was integrated with the possibility to modify its pore size from 500 nm to 1000 nm and more. As for the last step, sealing was completed by using a direct thermal bonding technique. A plastic coverslip was melted on top of the LOC device to ensure a hermetic seal. The fabricated device was tested by flowing distilled water and methanol through it. In result, distilled water stopped flowing after first microfilter, due to small pore size (500 nm). Instead, a lower viscosity value fluid, methanol was used and it successfully traveled throughout the device. Different flow rates were observed in outlet 1 and 2, proving that the fluid is being distributed throughout all three outlets.","abstract_has_math":false,"creators":["Andriukaitis, Deividas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T09:56:12Z","subjects":["Femtosecond laser, laser ablation, 3D laser lithorgraphy, macromolecule seprator, lab-on-chip, microfluidics."],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192970691&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192970691&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192970691","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Andriukaitis, Deividas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192970691/192970691.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Femtosecond laser, laser ablation, 3D laser lithorgraphy, macromolecule seprator, lab-on-chip, microfluidics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192970691&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The constant growth of technologies introduced a possibility to scale-down complex laboratory equipment – lab-on-chip (LOC). These devices work in the volume range from nanoliters to milliliters, so they excel in fast reaction time and low consumption of reagents. This work shows the possibility of producing a LOC device, a macromolecule separator, by employing a hybrid fabrication technique, which is the combination of subtractive and additive techniques. The device was fabricated in three steps. First is the ablation of the microchannel system, which was done by using a femtosecond laser to induce minimal thermal effects. The second part, integration of macromolecule separator was completed by employing three-dimensional laser lithography. The macromolecule separator was integrated with the possibility to modify its pore size from 500 nm to 1000 nm and more. As for the last step, sealing was completed by using a direct thermal bonding technique. A plastic coverslip was melted on top of the LOC device to ensure a hermetic seal. The fabricated device was tested by flowing distilled water and methanol through it. In result, distilled water stopped flowing after first microfilter, due to small pore size (500 nm). Instead, a lower viscosity value fluid, methanol was used and it successfully traveled throughout the device. Different flow rates were observed in outlet 1 and 2, proving that the fluid is being distributed throughout all three outlets."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Manufacturing of microfluidic micro- and nanoparticle separator via femtosecond laser /","Mikrofluidinio mikro- ir nanodalelių separatorių gamyba femtosekundiniu lazeriu."]}]}],"canonical_facts":{"dc:creator":["Andriukaitis, Deividas,"],"dc:date":["2022"],"dc:description":["The constant growth of technologies introduced a possibility to scale-down complex laboratory equipment – lab-on-chip (LOC). These devices work in the volume range from nanoliters to milliliters, so they excel in fast reaction time and low consumption of reagents. This work shows the possibility of producing a LOC device, a macromolecule separator, by employing a hybrid fabrication technique, which is the combination of subtractive and additive techniques. The device was fabricated in three steps. First is the ablation of the microchannel system, which was done by using a femtosecond laser to induce minimal thermal effects. The second part, integration of macromolecule separator was completed by employing three-dimensional laser lithography. The macromolecule separator was integrated with the possibility to modify its pore size from 500 nm to 1000 nm and more. As for the last step, sealing was completed by using a direct thermal bonding technique. A plastic coverslip was melted on top of the LOC device to ensure a hermetic seal. The fabricated device was tested by flowing distilled water and methanol through it. In result, distilled water stopped flowing after first microfilter, due to small pore size (500 nm). Instead, a lower viscosity value fluid, methanol was used and it successfully traveled throughout the device. Different flow rates were observed in outlet 1 and 2, proving that the fluid is being distributed throughout all three outlets."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192970691&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192970691/192970691.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["Femtosecond laser, laser ablation, 3D laser lithorgraphy, macromolecule seprator, lab-on-chip, microfluidics."],"dc:title":["Manufacturing of microfluidic micro- and nanoparticle separator via femtosecond laser /","Mikrofluidinio mikro- ir nanodalelių separatorių gamyba femtosekundiniu lazeriu."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:12Z"}