{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192973236"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192973236","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Jonizuojančiąja spinduliuote apšvitintų tripleksinių sensorių tyrimas nesąlytiniais metodais /","abstract":"Ionising radiation can cause harm to objects which it interacts with, e.g. living organisms, electronic devices. In various fields of work, such as medicine or high-energy physics experiments, it is important to monitor and measure the properties of radiation itself and the damage it causes to the objects it interacts with. A lot of detection methods exist, however every method has its own drawbacks/advantages for different purposes. Therefore, it is perspective to search for ways to combine multiple methods of particle detection in a sensor in order to increase measurement accuracy without compromising the size of the detector as well as the range of particle type, energy and dose which the detector would be able to register. In this work a triple response detector was formed by combining three layers of GaN, alanine and Si. Microwave probed photoconductivity (MW-PC) of Si layer, steady-state photoluminescence (SS-PL) of GaN layer and electron spin resonance (ESR) of alanine layer spectra of eighteen samples were recorded before and after the irradiation of 2,6 MeV and 13 MeV energy electrons and 2,6 MeV Röntgen rays at different doses. A comparative analysis of variations of the spectra before and after the irradiation is presented.","abstract_html":"Ionising radiation can cause harm to objects which it interacts with, e.g. living organisms, electronic devices. In various fields of work, such as medicine or high-energy physics experiments, it is important to monitor and measure the properties of radiation itself and the damage it causes to the objects it interacts with. A lot of detection methods exist, however every method has its own drawbacks/advantages for different purposes. Therefore, it is perspective to search for ways to combine multiple methods of particle detection in a sensor in order to increase measurement accuracy without compromising the size of the detector as well as the range of particle type, energy and dose which the detector would be able to register. In this work a triple response detector was formed by combining three layers of GaN, alanine and Si. Microwave probed photoconductivity (MW-PC) of Si layer, steady-state photoluminescence (SS-PL) of GaN layer and electron spin resonance (ESR) of alanine layer spectra of eighteen samples were recorded before and after the irradiation of 2,6 MeV and 13 MeV energy electrons and 2,6 MeV Röntgen rays at different doses. A comparative analysis of variations of the spectra before and after the irradiation is presented.","abstract_has_math":false,"creators":["Majauskas, Mindaugas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T09:56:19Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192973236&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192973236&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192973236","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Majauskas, Mindaugas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192973236/192973236.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192973236&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ionising radiation can cause harm to objects which it interacts with, e.g. living organisms, electronic devices. In various fields of work, such as medicine or high-energy physics experiments, it is important to monitor and measure the properties of radiation itself and the damage it causes to the objects it interacts with. A lot of detection methods exist, however every method has its own drawbacks/advantages for different purposes. Therefore, it is perspective to search for ways to combine multiple methods of particle detection in a sensor in order to increase measurement accuracy without compromising the size of the detector as well as the range of particle type, energy and dose which the detector would be able to register. In this work a triple response detector was formed by combining three layers of GaN, alanine and Si. Microwave probed photoconductivity (MW-PC) of Si layer, steady-state photoluminescence (SS-PL) of GaN layer and electron spin resonance (ESR) of alanine layer spectra of eighteen samples were recorded before and after the irradiation of 2,6 MeV and 13 MeV energy electrons and 2,6 MeV Röntgen rays at different doses. A comparative analysis of variations of the spectra before and after the irradiation is presented."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Jonizuojančiąja spinduliuote apšvitintų tripleksinių sensorių tyrimas nesąlytiniais metodais /","Investigation of triplex sensors irradiated by ionizing radiation using contactless methods."]}]}],"canonical_facts":{"dc:creator":["Majauskas, Mindaugas,"],"dc:date":["2022"],"dc:description":["Ionising radiation can cause harm to objects which it interacts with, e.g. living organisms, electronic devices. In various fields of work, such as medicine or high-energy physics experiments, it is important to monitor and measure the properties of radiation itself and the damage it causes to the objects it interacts with. A lot of detection methods exist, however every method has its own drawbacks/advantages for different purposes. Therefore, it is perspective to search for ways to combine multiple methods of particle detection in a sensor in order to increase measurement accuracy without compromising the size of the detector as well as the range of particle type, energy and dose which the detector would be able to register. In this work a triple response detector was formed by combining three layers of GaN, alanine and Si. Microwave probed photoconductivity (MW-PC) of Si layer, steady-state photoluminescence (SS-PL) of GaN layer and electron spin resonance (ESR) of alanine layer spectra of eighteen samples were recorded before and after the irradiation of 2,6 MeV and 13 MeV energy electrons and 2,6 MeV Röntgen rays at different doses. A comparative analysis of variations of the spectra before and after the irradiation is presented."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192973236&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192973236/192973236.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Jonizuojančiąja spinduliuote apšvitintų tripleksinių sensorių tyrimas nesąlytiniais metodais /","Investigation of triplex sensors irradiated by ionizing radiation using contactless methods."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:19Z"}