{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192974091"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192974091","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Subnanosekundinio parametrinio šviesos generatoriaus periodiškai orientuoto ličio niobato kristalo pagrindu kūrimas ir tyrimas /","abstract":"Subnanosecond (100 ps – 1 ns) optical parametric generators (OPGs) are continuously tunable in a wide spectral region and can be applied in spectroscopy, gas detection, biochemical research where high temporal resolution is not necessary but nanosecond time resolution is not sufficient enough. Such tunable coherent light sources are commercially attractive because of their quite simple configuration, compactness and relatively low-cost. Although there is demand, but only a few subnanosecond OPGs have been found because the damage threshold of nonlinear media for subnanosecond pulses limits the threshold of optical parametric generation. In this research, subnanosecond OPG and OPA were investigated using short periodically poled magnesium oxide doped lithium niobate (MgO:PPLN) crystals. Using 1 and 2 cm length crystals both configurations were pumped with Nd:YAG microlaser which generates 520 ps long 1064 nm wavelength pulses with 1 kHz repetition rate. Signal radiation covers 1439 – 2128 nm spectral region by utilizing temperature and domain period tuning. The maximum signal wave conversion efficiency was obtained to be ~ 32 % when using 2 cm crystal. OPA produced ~ 4% higher signal wave conversion efficiency, parametric generation threshold decreased 1.5 times and signal wave linewidth decreased around 3 times when compared to OPG. Optimal focusing conditions were investigated as well. It was found that &#958;= 0.7 value of pump focusing parameter corresponding to 160 µm pump beam waist diameter in a crystal offers the most efficient pump radiation conversion to parametric signal radiation in 2 cm crystal. It was found that OPG using 2 cm MgO:PPLN crystal has lower parametric generation threshold, higher signal wave conversion efficiency when compared to 1 cm crystal. OPA additionally reduces parametric generation threshold and signal wave linewidth.","abstract_html":"Subnanosecond (100 ps – 1 ns) optical parametric generators (OPGs) are continuously tunable in a wide spectral region and can be applied in spectroscopy, gas detection, biochemical research where high temporal resolution is not necessary but nanosecond time resolution is not sufficient enough. Such tunable coherent light sources are commercially attractive because of their quite simple configuration, compactness and relatively low-cost. Although there is demand, but only a few subnanosecond OPGs have been found because the damage threshold of nonlinear media for subnanosecond pulses limits the threshold of optical parametric generation. In this research, subnanosecond OPG and OPA were investigated using short periodically poled magnesium oxide doped lithium niobate (MgO:PPLN) crystals. Using 1 and 2 cm length crystals both configurations were pumped with Nd:YAG microlaser which generates 520 ps long 1064 nm wavelength pulses with 1 kHz repetition rate. Signal radiation covers 1439 – 2128 nm spectral region by utilizing temperature and domain period tuning. The maximum signal wave conversion efficiency was obtained to be ~ 32 % when using 2 cm crystal. OPA produced ~ 4% higher signal wave conversion efficiency, parametric generation threshold decreased 1.5 times and signal wave linewidth decreased around 3 times when compared to OPG. Optimal focusing conditions were investigated as well. It was found that &amp;#958;= 0.7 value of pump focusing parameter corresponding to 160 µm pump beam waist diameter in a crystal offers the most efficient pump radiation conversion to parametric signal radiation in 2 cm crystal. It was found that OPG using 2 cm MgO:PPLN crystal has lower parametric generation threshold, higher signal wave conversion efficiency when compared to 1 cm crystal. OPA additionally reduces parametric generation threshold and signal wave linewidth.","abstract_has_math":false,"creators":["Savickytė, Justina,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T09:56:19Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192974091&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192974091&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192974091","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Savickytė, Justina,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192974091/192974091.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192974091&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Subnanosecond (100 ps – 1 ns) optical parametric generators (OPGs) are continuously tunable in a wide spectral region and can be applied in spectroscopy, gas detection, biochemical research where high temporal resolution is not necessary but nanosecond time resolution is not sufficient enough. Such tunable coherent light sources are commercially attractive because of their quite simple configuration, compactness and relatively low-cost. Although there is demand, but only a few subnanosecond OPGs have been found because the damage threshold of nonlinear media for subnanosecond pulses limits the threshold of optical parametric generation. In this research, subnanosecond OPG and OPA were investigated using short periodically poled magnesium oxide doped lithium niobate (MgO:PPLN) crystals. Using 1 and 2 cm length crystals both configurations were pumped with Nd:YAG microlaser which generates 520 ps long 1064 nm wavelength pulses with 1 kHz repetition rate. Signal radiation covers 1439 – 2128 nm spectral region by utilizing temperature and domain period tuning. The maximum signal wave conversion efficiency was obtained to be ~ 32 % when using 2 cm crystal. OPA produced ~ 4% higher signal wave conversion efficiency, parametric generation threshold decreased 1.5 times and signal wave linewidth decreased around 3 times when compared to OPG. Optimal focusing conditions were investigated as well. It was found that &#958;= 0.7 value of pump focusing parameter corresponding to 160 µm pump beam waist diameter in a crystal offers the most efficient pump radiation conversion to parametric signal radiation in 2 cm crystal. It was found that OPG using 2 cm MgO:PPLN crystal has lower parametric generation threshold, higher signal wave conversion efficiency when compared to 1 cm crystal. OPA additionally reduces parametric generation threshold and signal wave linewidth."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Subnanosekundinio parametrinio šviesos generatoriaus periodiškai orientuoto ličio niobato kristalo pagrindu kūrimas ir tyrimas /","Construction and investigation of subnanosecond optical parametrical generator based on periodically poled lithium niobate crystal."]}]}],"canonical_facts":{"dc:creator":["Savickytė, Justina,"],"dc:date":["2022"],"dc:description":["Subnanosecond (100 ps – 1 ns) optical parametric generators (OPGs) are continuously tunable in a wide spectral region and can be applied in spectroscopy, gas detection, biochemical research where high temporal resolution is not necessary but nanosecond time resolution is not sufficient enough. Such tunable coherent light sources are commercially attractive because of their quite simple configuration, compactness and relatively low-cost. Although there is demand, but only a few subnanosecond OPGs have been found because the damage threshold of nonlinear media for subnanosecond pulses limits the threshold of optical parametric generation. In this research, subnanosecond OPG and OPA were investigated using short periodically poled magnesium oxide doped lithium niobate (MgO:PPLN) crystals. Using 1 and 2 cm length crystals both configurations were pumped with Nd:YAG microlaser which generates 520 ps long 1064 nm wavelength pulses with 1 kHz repetition rate. Signal radiation covers 1439 – 2128 nm spectral region by utilizing temperature and domain period tuning. The maximum signal wave conversion efficiency was obtained to be ~ 32 % when using 2 cm crystal. OPA produced ~ 4% higher signal wave conversion efficiency, parametric generation threshold decreased 1.5 times and signal wave linewidth decreased around 3 times when compared to OPG. Optimal focusing conditions were investigated as well. It was found that &#958;= 0.7 value of pump focusing parameter corresponding to 160 µm pump beam waist diameter in a crystal offers the most efficient pump radiation conversion to parametric signal radiation in 2 cm crystal. It was found that OPG using 2 cm MgO:PPLN crystal has lower parametric generation threshold, higher signal wave conversion efficiency when compared to 1 cm crystal. OPA additionally reduces parametric generation threshold and signal wave linewidth."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192974091&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192974091/192974091.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Subnanosekundinio parametrinio šviesos generatoriaus periodiškai orientuoto ličio niobato kristalo pagrindu kūrimas ir tyrimas /","Construction and investigation of subnanosecond optical parametrical generator based on periodically poled lithium niobate crystal."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:19Z"}