{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192974250"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192974250","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Prototipinės brachiterapijos planavimo įrangos kūrimas /","abstract":"This study has been addressed to the control of the real-time radionuclide positioning as well as to scanning of spatial distribution profiles of the absorbed dose in target material (of phantom or patient‘s body) during brachytherapy planning procedures. The procedure of forehand calibration of the dosimetry detectors has been invented and a Python programming packet for implementation of this procedure has been created. The methodology of the position determination has been developed based on triangulation technique. Having collected the dosimetry signals from detectors, the distances between detector and radionuclide can be evaluated. The relevance of this method for rapid estimation of the radionuclide position has been demonstrated using Varian brachytherapy instrument based on 192-Iridium radionuclide and anthropomorphic phantom. The TG-43 dosimetry formalism has been employed for visualization of the dose distribution planar cross-sections. The dosimetry Phyton code software based on TG-43 estimations was tested and approved at National Cancer Institute for verification of brachytherapy planning procedures.","abstract_html":"This study has been addressed to the control of the real-time radionuclide positioning as well as to scanning of spatial distribution profiles of the absorbed dose in target material (of phantom or patient‘s body) during brachytherapy planning procedures. The procedure of forehand calibration of the dosimetry detectors has been invented and a Python programming packet for implementation of this procedure has been created. The methodology of the position determination has been developed based on triangulation technique. Having collected the dosimetry signals from detectors, the distances between detector and radionuclide can be evaluated. The relevance of this method for rapid estimation of the radionuclide position has been demonstrated using Varian brachytherapy instrument based on 192-Iridium radionuclide and anthropomorphic phantom. The TG-43 dosimetry formalism has been employed for visualization of the dose distribution planar cross-sections. The dosimetry Phyton code software based on TG-43 estimations was tested and approved at National Cancer Institute for verification of brachytherapy planning procedures.","abstract_has_math":false,"creators":["Užgirytė, Milita,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T09:56:19Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192974250&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192974250&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192974250","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Užgirytė, Milita,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192974250&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study has been addressed to the control of the real-time radionuclide positioning as well as to scanning of spatial distribution profiles of the absorbed dose in target material (of phantom or patient‘s body) during brachytherapy planning procedures. The procedure of forehand calibration of the dosimetry detectors has been invented and a Python programming packet for implementation of this procedure has been created. The methodology of the position determination has been developed based on triangulation technique. Having collected the dosimetry signals from detectors, the distances between detector and radionuclide can be evaluated. The relevance of this method for rapid estimation of the radionuclide position has been demonstrated using Varian brachytherapy instrument based on 192-Iridium radionuclide and anthropomorphic phantom. The TG-43 dosimetry formalism has been employed for visualization of the dose distribution planar cross-sections. The dosimetry Phyton code software based on TG-43 estimations was tested and approved at National Cancer Institute for verification of brachytherapy planning procedures."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Prototipinės brachiterapijos planavimo įrangos kūrimas /","Development of prototype brachytherapy planning system."]}]}],"canonical_facts":{"dc:creator":["Užgirytė, Milita,"],"dc:date":["2022"],"dc:description":["This study has been addressed to the control of the real-time radionuclide positioning as well as to scanning of spatial distribution profiles of the absorbed dose in target material (of phantom or patient‘s body) during brachytherapy planning procedures. The procedure of forehand calibration of the dosimetry detectors has been invented and a Python programming packet for implementation of this procedure has been created. The methodology of the position determination has been developed based on triangulation technique. Having collected the dosimetry signals from detectors, the distances between detector and radionuclide can be evaluated. The relevance of this method for rapid estimation of the radionuclide position has been demonstrated using Varian brachytherapy instrument based on 192-Iridium radionuclide and anthropomorphic phantom. The TG-43 dosimetry formalism has been employed for visualization of the dose distribution planar cross-sections. The dosimetry Phyton code software based on TG-43 estimations was tested and approved at National Cancer Institute for verification of brachytherapy planning procedures."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192974250&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Prototipinės brachiterapijos planavimo įrangos kūrimas /","Development of prototype brachytherapy planning system."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:19Z"}