{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:192974435"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:192974435","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Kvantinių kaskadinių lazerių elektrinių ir optinių parametrų charakterizavimas /","abstract":"Development of efficient mid-infrared quantum cascade lasers (QCL) for wide variety of applications is a point of interest of large number of scientific and industrial groups. Development and optimisation process includes iterations of modelling parameters adjustments based on results acquired from technological process and consequent measurements of properties of fabricated devices. This process requires very fast feedback and high accuracy and reliability measurements. Automating the measurement process and optimisation of measurement technique minimizes the likelihood of human error improving reliability and drastically reducing feedback time. For this reason, an automated measurement system was created using NI LabVIEW visual programming environment, and the main properties of at FTMC developed quantum cascade lasers were evaluated. Measurement results exhibited that the applied very short duration electrical current pulse measurement technique and written measurement automation program is efficient for characterisation of quantum cascade lasers. Very high measurement accuracy and repeatability is achieved. Measured properties of two QCL devices revealed very strong electrical current leakage on longer emission wavelength device pointing on necessity of further investigations while the short wavelength structure exhibited projected optical and electrical properties.","abstract_html":"Development of efficient mid-infrared quantum cascade lasers (QCL) for wide variety of applications is a point of interest of large number of scientific and industrial groups. Development and optimisation process includes iterations of modelling parameters adjustments based on results acquired from technological process and consequent measurements of properties of fabricated devices. This process requires very fast feedback and high accuracy and reliability measurements. Automating the measurement process and optimisation of measurement technique minimizes the likelihood of human error improving reliability and drastically reducing feedback time. For this reason, an automated measurement system was created using NI LabVIEW visual programming environment, and the main properties of at FTMC developed quantum cascade lasers were evaluated. Measurement results exhibited that the applied very short duration electrical current pulse measurement technique and written measurement automation program is efficient for characterisation of quantum cascade lasers. Very high measurement accuracy and repeatability is achieved. Measured properties of two QCL devices revealed very strong electrical current leakage on longer emission wavelength device pointing on necessity of further investigations while the short wavelength structure exhibited projected optical and electrical properties.","abstract_has_math":false,"creators":["Berškys, Jaunius,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T09:56:19Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD192974435&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD192974435&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A192974435","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Berškys, Jaunius,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:192974435/192974435.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD192974435&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Development of efficient mid-infrared quantum cascade lasers (QCL) for wide variety of applications is a point of interest of large number of scientific and industrial groups. Development and optimisation process includes iterations of modelling parameters adjustments based on results acquired from technological process and consequent measurements of properties of fabricated devices. This process requires very fast feedback and high accuracy and reliability measurements. Automating the measurement process and optimisation of measurement technique minimizes the likelihood of human error improving reliability and drastically reducing feedback time. For this reason, an automated measurement system was created using NI LabVIEW visual programming environment, and the main properties of at FTMC developed quantum cascade lasers were evaluated. Measurement results exhibited that the applied very short duration electrical current pulse measurement technique and written measurement automation program is efficient for characterisation of quantum cascade lasers. Very high measurement accuracy and repeatability is achieved. Measured properties of two QCL devices revealed very strong electrical current leakage on longer emission wavelength device pointing on necessity of further investigations while the short wavelength structure exhibited projected optical and electrical properties."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Kvantinių kaskadinių lazerių elektrinių ir optinių parametrų charakterizavimas /","Quantum cascade lasers electrical and optical parameters characterization."]}]}],"canonical_facts":{"dc:creator":["Berškys, Jaunius,"],"dc:date":["2022"],"dc:description":["Development of efficient mid-infrared quantum cascade lasers (QCL) for wide variety of applications is a point of interest of large number of scientific and industrial groups. Development and optimisation process includes iterations of modelling parameters adjustments based on results acquired from technological process and consequent measurements of properties of fabricated devices. This process requires very fast feedback and high accuracy and reliability measurements. Automating the measurement process and optimisation of measurement technique minimizes the likelihood of human error improving reliability and drastically reducing feedback time. For this reason, an automated measurement system was created using NI LabVIEW visual programming environment, and the main properties of at FTMC developed quantum cascade lasers were evaluated. Measurement results exhibited that the applied very short duration electrical current pulse measurement technique and written measurement automation program is efficient for characterisation of quantum cascade lasers. Very high measurement accuracy and repeatability is achieved. Measured properties of two QCL devices revealed very strong electrical current leakage on longer emission wavelength device pointing on necessity of further investigations while the short wavelength structure exhibited projected optical and electrical properties."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD192974435&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:192974435/192974435.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Kvantinių kaskadinių lazerių elektrinių ir optinių parametrų charakterizavimas /","Quantum cascade lasers electrical and optical parameters characterization."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:19Z"}