{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:193226698"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:193226698","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Efektyviosios skysčių chromatografijos metodas salbutamolio sulfato ir ipratropio bromido likučių nustatymui inhaliatorių filtruose /","abstract":"An effective and sensitive high performance liquid chromatography method was developed and validated for determination of salbutamol sulphate and ipratropium bromide residue on inhaler filters. Chromatographic seperation was performed at 25 oC using 150 × 4,7 mm ZORBAX Eclipse 3 C18 column with particle size of 3 µm. Mobile phase, consisting of 30 mM potassium phosphate buffer (pH 3,0) and acetonitrile (90:10, v/v), was supplied at flow rate of 1 ml/min using gradient elution. Ultraviolet detection was performed at 210 and 225 nm. Retention time of salbutamol sulphate and ipratropium bromide was 3,0 and 5,6 min. RSD was found to be 0,02-0,04 % for salbutamol sulphate and 0,01-0,04% for ipratropium bromide, recovery was 98,9 % and 96,6 % respectively. Three different ways were used to determine limit of detection and limit of quantification and calculated values were compared. Good linearity between concentration and response was observed for both analytes over concentration range of 1-110 µg/g. The developed method was used to determine salbutamol sulphate and ipratropium bromide residue on used inhaler filters.","abstract_html":"An effective and sensitive high performance liquid chromatography method was developed and validated for determination of salbutamol sulphate and ipratropium bromide residue on inhaler filters. Chromatographic seperation was performed at 25 oC using 150 × 4,7 mm ZORBAX Eclipse 3 C18 column with particle size of 3 µm. Mobile phase, consisting of 30 mM potassium phosphate buffer (pH 3,0) and acetonitrile (90:10, v/v), was supplied at flow rate of 1 ml/min using gradient elution. Ultraviolet detection was performed at 210 and 225 nm. Retention time of salbutamol sulphate and ipratropium bromide was 3,0 and 5,6 min. RSD was found to be 0,02-0,04 % for salbutamol sulphate and 0,01-0,04% for ipratropium bromide, recovery was 98,9 % and 96,6 % respectively. Three different ways were used to determine limit of detection and limit of quantification and calculated values were compared. Good linearity between concentration and response was observed for both analytes over concentration range of 1-110 µg/g. The developed method was used to determine salbutamol sulphate and ipratropium bromide residue on used inhaler filters.","abstract_has_math":false,"creators":["Balčiūnas, Simonas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T09:56:45Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD193226698&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD193226698&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A193226698","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Balčiūnas, Simonas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:193226698/193226698.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD193226698&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An effective and sensitive high performance liquid chromatography method was developed and validated for determination of salbutamol sulphate and ipratropium bromide residue on inhaler filters. Chromatographic seperation was performed at 25 oC using 150 × 4,7 mm ZORBAX Eclipse 3 C18 column with particle size of 3 µm. Mobile phase, consisting of 30 mM potassium phosphate buffer (pH 3,0) and acetonitrile (90:10, v/v), was supplied at flow rate of 1 ml/min using gradient elution. Ultraviolet detection was performed at 210 and 225 nm. Retention time of salbutamol sulphate and ipratropium bromide was 3,0 and 5,6 min. RSD was found to be 0,02-0,04 % for salbutamol sulphate and 0,01-0,04% for ipratropium bromide, recovery was 98,9 % and 96,6 % respectively. Three different ways were used to determine limit of detection and limit of quantification and calculated values were compared. Good linearity between concentration and response was observed for both analytes over concentration range of 1-110 µg/g. The developed method was used to determine salbutamol sulphate and ipratropium bromide residue on used inhaler filters."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Efektyviosios skysčių chromatografijos metodas salbutamolio sulfato ir ipratropio bromido likučių nustatymui inhaliatorių filtruose /","Simultaneous determination of salbutamol sulfate and ipratropium bromide residues on inhalers filters using high performance liquid chromatography."]}]}],"canonical_facts":{"dc:creator":["Balčiūnas, Simonas,"],"dc:date":["2021"],"dc:description":["An effective and sensitive high performance liquid chromatography method was developed and validated for determination of salbutamol sulphate and ipratropium bromide residue on inhaler filters. Chromatographic seperation was performed at 25 oC using 150 × 4,7 mm ZORBAX Eclipse 3 C18 column with particle size of 3 µm. Mobile phase, consisting of 30 mM potassium phosphate buffer (pH 3,0) and acetonitrile (90:10, v/v), was supplied at flow rate of 1 ml/min using gradient elution. Ultraviolet detection was performed at 210 and 225 nm. Retention time of salbutamol sulphate and ipratropium bromide was 3,0 and 5,6 min. RSD was found to be 0,02-0,04 % for salbutamol sulphate and 0,01-0,04% for ipratropium bromide, recovery was 98,9 % and 96,6 % respectively. Three different ways were used to determine limit of detection and limit of quantification and calculated values were compared. Good linearity between concentration and response was observed for both analytes over concentration range of 1-110 µg/g. The developed method was used to determine salbutamol sulphate and ipratropium bromide residue on used inhaler filters."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD193226698&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:193226698/193226698.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Efektyviosios skysčių chromatografijos metodas salbutamolio sulfato ir ipratropio bromido likučių nustatymui inhaliatorių filtruose /","Simultaneous determination of salbutamol sulfate and ipratropium bromide residues on inhalers filters using high performance liquid chromatography."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:45Z"}