{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:193228389"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:193228389","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Galvanostatinių impulsų metodu platinuotų titano elektrodų taikymas cianidinių tirpalų elektrooksidacijai /","abstract":"Titanium electrodes have been coated with 500 nm thick platinum coating by galvanostatic pulsed method where an electric current is stopped for 1 minute intervals at certain points in time to help form new crystallization centers. Thus platinum coated Ti electrodes were used in the electrooxidation of cyanide solutions. Most platinum was coated with electrode B1 (power cut off for 1 minute after 12 minutes) (38,1%) and electrode C1 (power cut off for 1 minute after 1 minute) (33,9%). Electrodes A (electric current was constant), B1, E (current stopped for 1 minute after 1, 2 and 3 minutes), C and C1 were covered most evenly. Cyanide was most efficiently oxidized by electrode A, as after 5 h of electrooxidation the CN- concentration decreased from 0.1 M to 0.023 M. The cyanide concentration was reduced by the A1, C, C1 electrodes to 0.038 M. The B1 electrode effectively oxidized cyanide in the first hours, but after 3 hours the efficiency decreased rapidly, the cyanide concentration decreased to 0.05 M. The electric current shutdown helped to cover platinum more abundantly on the titanium electrode, but it oxidized cyanide solutions less well. It could be argued that the coated platinum adhered less weakly to the surface of the titanium electrode.","abstract_html":"Titanium electrodes have been coated with 500 nm thick platinum coating by galvanostatic pulsed method where an electric current is stopped for 1 minute intervals at certain points in time to help form new crystallization centers. Thus platinum coated Ti electrodes were used in the electrooxidation of cyanide solutions. Most platinum was coated with electrode B1 (power cut off for 1 minute after 12 minutes) (38,1%) and electrode C1 (power cut off for 1 minute after 1 minute) (33,9%). Electrodes A (electric current was constant), B1, E (current stopped for 1 minute after 1, 2 and 3 minutes), C and C1 were covered most evenly. Cyanide was most efficiently oxidized by electrode A, as after 5 h of electrooxidation the CN- concentration decreased from 0.1 M to 0.023 M. The cyanide concentration was reduced by the A1, C, C1 electrodes to 0.038 M. The B1 electrode effectively oxidized cyanide in the first hours, but after 3 hours the efficiency decreased rapidly, the cyanide concentration decreased to 0.05 M. The electric current shutdown helped to cover platinum more abundantly on the titanium electrode, but it oxidized cyanide solutions less well. It could be argued that the coated platinum adhered less weakly to the surface of the titanium electrode.","abstract_has_math":false,"creators":["Grigorjevas, Rytis,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T09:56:48Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD193228389&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD193228389&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A193228389","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Grigorjevas, Rytis,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:193228389/193228389.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD193228389&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Titanium electrodes have been coated with 500 nm thick platinum coating by galvanostatic pulsed method where an electric current is stopped for 1 minute intervals at certain points in time to help form new crystallization centers. Thus platinum coated Ti electrodes were used in the electrooxidation of cyanide solutions. Most platinum was coated with electrode B1 (power cut off for 1 minute after 12 minutes) (38,1%) and electrode C1 (power cut off for 1 minute after 1 minute) (33,9%). Electrodes A (electric current was constant), B1, E (current stopped for 1 minute after 1, 2 and 3 minutes), C and C1 were covered most evenly. Cyanide was most efficiently oxidized by electrode A, as after 5 h of electrooxidation the CN- concentration decreased from 0.1 M to 0.023 M. The cyanide concentration was reduced by the A1, C, C1 electrodes to 0.038 M. The B1 electrode effectively oxidized cyanide in the first hours, but after 3 hours the efficiency decreased rapidly, the cyanide concentration decreased to 0.05 M. The electric current shutdown helped to cover platinum more abundantly on the titanium electrode, but it oxidized cyanide solutions less well. It could be argued that the coated platinum adhered less weakly to the surface of the titanium electrode."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Galvanostatinių impulsų metodu platinuotų titano elektrodų taikymas cianidinių tirpalų elektrooksidacijai /","Application of platinum-coated titanium electrodes by galvanostatic pulse method for electrooxidation of cyanide solutions."]}]}],"canonical_facts":{"dc:creator":["Grigorjevas, Rytis,"],"dc:date":["2021"],"dc:description":["Titanium electrodes have been coated with 500 nm thick platinum coating by galvanostatic pulsed method where an electric current is stopped for 1 minute intervals at certain points in time to help form new crystallization centers. Thus platinum coated Ti electrodes were used in the electrooxidation of cyanide solutions. Most platinum was coated with electrode B1 (power cut off for 1 minute after 12 minutes) (38,1%) and electrode C1 (power cut off for 1 minute after 1 minute) (33,9%). Electrodes A (electric current was constant), B1, E (current stopped for 1 minute after 1, 2 and 3 minutes), C and C1 were covered most evenly. Cyanide was most efficiently oxidized by electrode A, as after 5 h of electrooxidation the CN- concentration decreased from 0.1 M to 0.023 M. The cyanide concentration was reduced by the A1, C, C1 electrodes to 0.038 M. The B1 electrode effectively oxidized cyanide in the first hours, but after 3 hours the efficiency decreased rapidly, the cyanide concentration decreased to 0.05 M. The electric current shutdown helped to cover platinum more abundantly on the titanium electrode, but it oxidized cyanide solutions less well. It could be argued that the coated platinum adhered less weakly to the surface of the titanium electrode."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD193228389&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:193228389/193228389.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Galvanostatinių impulsų metodu platinuotų titano elektrodų taikymas cianidinių tirpalų elektrooksidacijai /","Application of platinum-coated titanium electrodes by galvanostatic pulse method for electrooxidation of cyanide solutions."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:56:48Z"}