{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:193352601"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:193352601","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Konfigūruojamos THz matricos elektronikos kūrimas /","abstract":"Terahertz (100GHz - 10THz) technologies is undergoing rapid research and development due to their potential to wide range of applications. It was recently shown that THz radiation can be efficiently detected by field effect transistors. This enables large scale production of detectors by employing well developed semiconductor fabrication technologies. One of new opportunities for applications brought by these technologies is a possibility to implement detector with configurable effective cross section. Such detector could allow to scan beam profile, one can configure a detector adapted to the desired beam cross section. This work demonstrates THz detector matrix control and scanning method, allowing easy expansion to bigger matrices. This work describes principles of operation of control electronics, use of digital potentiometers for gate voltage control, low noise amplifier design. Designed control circuitry does not introduce a significant amount of noise to the measured signal. Using developed control electronics , the matrix of AlGaN/GaN 7x6 sensor array was studied. It was found that an increase of SNR by 3,3 dB was achieved by reconfiguring detector matrix. The most important characteristics of the detector were studied: resistance, sensitivity and NEP dependence to gate voltage. Sensitivity and NEP frequency characteristics was measured in range from 50 GHz to 1200 GHz. Best sensitivity achieved was 115,2 V/W and NEP NEP 93 pW/&#8730;Hz at 278 GHz.","abstract_html":"Terahertz (100GHz - 10THz) technologies is undergoing rapid research and development due to their potential to wide range of applications. It was recently shown that THz radiation can be efficiently detected by field effect transistors. This enables large scale production of detectors by employing well developed semiconductor fabrication technologies. One of new opportunities for applications brought by these technologies is a possibility to implement detector with configurable effective cross section. Such detector could allow to scan beam profile, one can configure a detector adapted to the desired beam cross section. This work demonstrates THz detector matrix control and scanning method, allowing easy expansion to bigger matrices. This work describes principles of operation of control electronics, use of digital potentiometers for gate voltage control, low noise amplifier design. Designed control circuitry does not introduce a significant amount of noise to the measured signal. Using developed control electronics , the matrix of AlGaN/GaN 7x6 sensor array was studied. It was found that an increase of SNR by 3,3 dB was achieved by reconfiguring detector matrix. The most important characteristics of the detector were studied: resistance, sensitivity and NEP dependence to gate voltage. Sensitivity and NEP frequency characteristics was measured in range from 50 GHz to 1200 GHz. Best sensitivity achieved was 115,2 V/W and NEP NEP 93 pW/&amp;#8730;Hz at 278 GHz.","abstract_has_math":false,"creators":["Razgūnas, Matas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T09:57:15Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD193352601&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD193352601&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A193352601","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Razgūnas, Matas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:193352601/193352601.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD193352601&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Terahertz (100GHz - 10THz) technologies is undergoing rapid research and development due to their potential to wide range of applications. It was recently shown that THz radiation can be efficiently detected by field effect transistors. This enables large scale production of detectors by employing well developed semiconductor fabrication technologies. One of new opportunities for applications brought by these technologies is a possibility to implement detector with configurable effective cross section. Such detector could allow to scan beam profile, one can configure a detector adapted to the desired beam cross section. This work demonstrates THz detector matrix control and scanning method, allowing easy expansion to bigger matrices. This work describes principles of operation of control electronics, use of digital potentiometers for gate voltage control, low noise amplifier design. Designed control circuitry does not introduce a significant amount of noise to the measured signal. Using developed control electronics , the matrix of AlGaN/GaN 7x6 sensor array was studied. It was found that an increase of SNR by 3,3 dB was achieved by reconfiguring detector matrix. The most important characteristics of the detector were studied: resistance, sensitivity and NEP dependence to gate voltage. Sensitivity and NEP frequency characteristics was measured in range from 50 GHz to 1200 GHz. Best sensitivity achieved was 115,2 V/W and NEP NEP 93 pW/&#8730;Hz at 278 GHz."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Konfigūruojamos THz matricos elektronikos kūrimas /","Control electronics for reconfigurable thz detector array."]}]}],"canonical_facts":{"dc:creator":["Razgūnas, Matas,"],"dc:date":["2019"],"dc:description":["Terahertz (100GHz - 10THz) technologies is undergoing rapid research and development due to their potential to wide range of applications. It was recently shown that THz radiation can be efficiently detected by field effect transistors. This enables large scale production of detectors by employing well developed semiconductor fabrication technologies. One of new opportunities for applications brought by these technologies is a possibility to implement detector with configurable effective cross section. Such detector could allow to scan beam profile, one can configure a detector adapted to the desired beam cross section. This work demonstrates THz detector matrix control and scanning method, allowing easy expansion to bigger matrices. This work describes principles of operation of control electronics, use of digital potentiometers for gate voltage control, low noise amplifier design. Designed control circuitry does not introduce a significant amount of noise to the measured signal. Using developed control electronics , the matrix of AlGaN/GaN 7x6 sensor array was studied. It was found that an increase of SNR by 3,3 dB was achieved by reconfiguring detector matrix. The most important characteristics of the detector were studied: resistance, sensitivity and NEP dependence to gate voltage. Sensitivity and NEP frequency characteristics was measured in range from 50 GHz to 1200 GHz. Best sensitivity achieved was 115,2 V/W and NEP NEP 93 pW/&#8730;Hz at 278 GHz."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD193352601&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:193352601/193352601.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Konfigūruojamos THz matricos elektronikos kūrimas /","Control electronics for reconfigurable thz detector array."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:57:15Z"}