{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:193353831"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:193353831","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Netiesinio lūžio rodiklio matavimas žadinant femtosekundiniais impulsais infraraudonojoje srityje /","abstract":"In the regime of nonlinear optics, the magnitude of the refractive index of the medium changes with increasing light intensity - an effect which can be described by a constant called nonlinear refractive index or n2. It is a highly important property of all optical materials. One way to measure it experimentally is to analyze phase front variations which occur when medium is excited with high intensity laser radiation. The main purpose of this work was to determine n2 values of fused silica, sapphire and BK7 in near infrared. Therefore, two separate z-scan systems were constructed, employing 800 nm Ti:sapphire and 1030 nm Yb:KGW laser system radiation as pump. Measurements in NIR (near infrared) should serve as ground work for expanding experiments further into infrared. With used z-scan experimental setup relative values of nonlinear refractive index for investigated samples were determined. Deviation from the expected n2 values might be due to non-Gaussian distribution and non-ideal temporal pulse envelope as well as due to unsatisfied far-field condition for an aperture and inaccurate determination of pulse duration and beam radius.","abstract_html":"In the regime of nonlinear optics, the magnitude of the refractive index of the medium changes with increasing light intensity - an effect which can be described by a constant called nonlinear refractive index or n2. It is a highly important property of all optical materials. One way to measure it experimentally is to analyze phase front variations which occur when medium is excited with high intensity laser radiation. The main purpose of this work was to determine n2 values of fused silica, sapphire and BK7 in near infrared. Therefore, two separate z-scan systems were constructed, employing 800 nm Ti:sapphire and 1030 nm Yb:KGW laser system radiation as pump. Measurements in NIR (near infrared) should serve as ground work for expanding experiments further into infrared. With used z-scan experimental setup relative values of nonlinear refractive index for investigated samples were determined. Deviation from the expected n2 values might be due to non-Gaussian distribution and non-ideal temporal pulse envelope as well as due to unsatisfied far-field condition for an aperture and inaccurate determination of pulse duration and beam radius.","abstract_has_math":false,"creators":["Strakšytė, Jurgita,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T09:57:15Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD193353831&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD193353831&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A193353831","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Strakšytė, Jurgita,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:193353831/193353831.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD193353831&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the regime of nonlinear optics, the magnitude of the refractive index of the medium changes with increasing light intensity - an effect which can be described by a constant called nonlinear refractive index or n2. It is a highly important property of all optical materials. One way to measure it experimentally is to analyze phase front variations which occur when medium is excited with high intensity laser radiation. The main purpose of this work was to determine n2 values of fused silica, sapphire and BK7 in near infrared. Therefore, two separate z-scan systems were constructed, employing 800 nm Ti:sapphire and 1030 nm Yb:KGW laser system radiation as pump. Measurements in NIR (near infrared) should serve as ground work for expanding experiments further into infrared. With used z-scan experimental setup relative values of nonlinear refractive index for investigated samples were determined. Deviation from the expected n2 values might be due to non-Gaussian distribution and non-ideal temporal pulse envelope as well as due to unsatisfied far-field condition for an aperture and inaccurate determination of pulse duration and beam radius."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Netiesinio lūžio rodiklio matavimas žadinant femtosekundiniais impulsais infraraudonojoje srityje /","Measurement of nonlinear refractive index using femtosecond pulses in the infrared."]}]}],"canonical_facts":{"dc:creator":["Strakšytė, Jurgita,"],"dc:date":["2019"],"dc:description":["In the regime of nonlinear optics, the magnitude of the refractive index of the medium changes with increasing light intensity - an effect which can be described by a constant called nonlinear refractive index or n2. It is a highly important property of all optical materials. One way to measure it experimentally is to analyze phase front variations which occur when medium is excited with high intensity laser radiation. The main purpose of this work was to determine n2 values of fused silica, sapphire and BK7 in near infrared. Therefore, two separate z-scan systems were constructed, employing 800 nm Ti:sapphire and 1030 nm Yb:KGW laser system radiation as pump. Measurements in NIR (near infrared) should serve as ground work for expanding experiments further into infrared. With used z-scan experimental setup relative values of nonlinear refractive index for investigated samples were determined. Deviation from the expected n2 values might be due to non-Gaussian distribution and non-ideal temporal pulse envelope as well as due to unsatisfied far-field condition for an aperture and inaccurate determination of pulse duration and beam radius."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD193353831&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:193353831/193353831.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Netiesinio lūžio rodiklio matavimas žadinant femtosekundiniais impulsais infraraudonojoje srityje /","Measurement of nonlinear refractive index using femtosecond pulses in the infrared."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:57:15Z"}