{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:20203890"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:20203890","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Kolonėlės perkrovos efektai atvirkščių fazių ir hidrofilinės sąveikos skysčių chromatografijoje /","abstract":"The effect of column overload under hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) conditions was systematically investigated. The influence of the sample volume and mass overload onto potassium benzoate and nicotine retention time and peak shape was tested under certain experiment terms (pH, temperature, buffer concentration and solvent volume) and compared. It was evaluated, that under neutral pH BEH HILIC column‘s capacity, depending on the nature of the analyte, is 5 – 20 times higher than BEH Shield RP column. Also, it was shown that under RPLC method column's capacity depends on the mobile phase pH and ionic strenght whereas in HILIC this dependency was not that evident. Increasing the temperature of the column reduced column‘s capacity about 2 – 5 times or did not have significant influence (at pH = 7,0 and 5,0 respectively). The volume of the solvent did not affect overload occurrences in any way. Lastly, it was estimated that mass and volume overload in both, HILIC and RPLC, takes place under the same amount of molecules of the analytes.","abstract_html":"The effect of column overload under hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) conditions was systematically investigated. The influence of the sample volume and mass overload onto potassium benzoate and nicotine retention time and peak shape was tested under certain experiment terms (pH, temperature, buffer concentration and solvent volume) and compared. It was evaluated, that under neutral pH BEH HILIC column‘s capacity, depending on the nature of the analyte, is 5 – 20 times higher than BEH Shield RP column. Also, it was shown that under RPLC method column&#x27;s capacity depends on the mobile phase pH and ionic strenght whereas in HILIC this dependency was not that evident. Increasing the temperature of the column reduced column‘s capacity about 2 – 5 times or did not have significant influence (at pH = 7,0 and 5,0 respectively). The volume of the solvent did not affect overload occurrences in any way. Lastly, it was estimated that mass and volume overload in both, HILIC and RPLC, takes place under the same amount of molecules of the analytes.","abstract_has_math":false,"creators":["Svirelis, Justas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Olšauskaitė, Vilma"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T09:43:04Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD20203890&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD20203890&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A20203890","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Olšauskaitė, Vilma"]},{"key":"dc:creator","label":"Author","values":["Svirelis, Justas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:20203890/20203890.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD20203890&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The effect of column overload under hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) conditions was systematically investigated. The influence of the sample volume and mass overload onto potassium benzoate and nicotine retention time and peak shape was tested under certain experiment terms (pH, temperature, buffer concentration and solvent volume) and compared. It was evaluated, that under neutral pH BEH HILIC column‘s capacity, depending on the nature of the analyte, is 5 – 20 times higher than BEH Shield RP column. Also, it was shown that under RPLC method column's capacity depends on the mobile phase pH and ionic strenght whereas in HILIC this dependency was not that evident. Increasing the temperature of the column reduced column‘s capacity about 2 – 5 times or did not have significant influence (at pH = 7,0 and 5,0 respectively). The volume of the solvent did not affect overload occurrences in any way. Lastly, it was estimated that mass and volume overload in both, HILIC and RPLC, takes place under the same amount of molecules of the analytes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Kolonėlės perkrovos efektai atvirkščių fazių ir hidrofilinės sąveikos skysčių chromatografijoje /","Effects of column overload in reversed-phase and hydrophilic interaction chromatograpy."]}]}],"canonical_facts":{"dc:contributor":["Olšauskaitė, Vilma"],"dc:creator":["Svirelis, Justas,"],"dc:date":["2016"],"dc:description":["The effect of column overload under hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) conditions was systematically investigated. The influence of the sample volume and mass overload onto potassium benzoate and nicotine retention time and peak shape was tested under certain experiment terms (pH, temperature, buffer concentration and solvent volume) and compared. It was evaluated, that under neutral pH BEH HILIC column‘s capacity, depending on the nature of the analyte, is 5 – 20 times higher than BEH Shield RP column. Also, it was shown that under RPLC method column's capacity depends on the mobile phase pH and ionic strenght whereas in HILIC this dependency was not that evident. Increasing the temperature of the column reduced column‘s capacity about 2 – 5 times or did not have significant influence (at pH = 7,0 and 5,0 respectively). The volume of the solvent did not affect overload occurrences in any way. Lastly, it was estimated that mass and volume overload in both, HILIC and RPLC, takes place under the same amount of molecules of the analytes."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD20203890&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:20203890/20203890.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Kolonėlės perkrovos efektai atvirkščių fazių ir hidrofilinės sąveikos skysčių chromatografijoje /","Effects of column overload in reversed-phase and hydrophilic interaction chromatograpy."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:43:04Z"}