{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:20217431"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:20217431","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Nustatymo ribos matavimo būdų skysčių chromatografijoje palyginimas /","abstract":"Comparison of the Approaches to Estimate Limit of Quantification in Liquid Chromatography Limit of quantification (LOQ) is perhaps the most important performance characteristic in analytical method validation. In the present work three methods based on the signal-to-noise ratio, linear regression and Eurachem guidelines were compared to estimate the limits of quantification for two parabens using high performance liquid chromatography. Both, instrumental and method LOQs were estimated and compared. The results indicated that the measured LOQs were not equal and varied by a factor of 10 for the different techniques. The lowest LOQ values (0.12-0.17 mg/L) were obtained by linear regression method, the highest (0.81-1.72 mg/L) – based on Eurachem guidelines. It is therefore important to have clearly described procedure for measuring the LOQ during validation to allow interlaboratory comparison. In our opinion, the best approach was a methodology based on signal-to noise ratio.","abstract_html":"Comparison of the Approaches to Estimate Limit of Quantification in Liquid Chromatography Limit of quantification (LOQ) is perhaps the most important performance characteristic in analytical method validation. In the present work three methods based on the signal-to-noise ratio, linear regression and Eurachem guidelines were compared to estimate the limits of quantification for two parabens using high performance liquid chromatography. Both, instrumental and method LOQs were estimated and compared. The results indicated that the measured LOQs were not equal and varied by a factor of 10 for the different techniques. The lowest LOQ values (0.12-0.17 mg/L) were obtained by linear regression method, the highest (0.81-1.72 mg/L) – based on Eurachem guidelines. It is therefore important to have clearly described procedure for measuring the LOQ during validation to allow interlaboratory comparison. In our opinion, the best approach was a methodology based on signal-to noise ratio.","abstract_has_math":false,"creators":["Choromanskis, Andrius,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Padarauskas, Audrius"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T09:43:09Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD20217431&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD20217431&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A20217431","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Padarauskas, Audrius"]},{"key":"dc:creator","label":"Author","values":["Choromanskis, Andrius,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:20217431/20217431.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD20217431&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Comparison of the Approaches to Estimate Limit of Quantification in Liquid Chromatography Limit of quantification (LOQ) is perhaps the most important performance characteristic in analytical method validation. In the present work three methods based on the signal-to-noise ratio, linear regression and Eurachem guidelines were compared to estimate the limits of quantification for two parabens using high performance liquid chromatography. Both, instrumental and method LOQs were estimated and compared. The results indicated that the measured LOQs were not equal and varied by a factor of 10 for the different techniques. The lowest LOQ values (0.12-0.17 mg/L) were obtained by linear regression method, the highest (0.81-1.72 mg/L) – based on Eurachem guidelines. It is therefore important to have clearly described procedure for measuring the LOQ during validation to allow interlaboratory comparison. In our opinion, the best approach was a methodology based on signal-to noise ratio."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Nustatymo ribos matavimo būdų skysčių chromatografijoje palyginimas /","Comparison of the approaches to estimate limit of quantification in liquid chromatography."]}]}],"canonical_facts":{"dc:contributor":["Padarauskas, Audrius"],"dc:creator":["Choromanskis, Andrius,"],"dc:date":["2016"],"dc:description":["Comparison of the Approaches to Estimate Limit of Quantification in Liquid Chromatography Limit of quantification (LOQ) is perhaps the most important performance characteristic in analytical method validation. In the present work three methods based on the signal-to-noise ratio, linear regression and Eurachem guidelines were compared to estimate the limits of quantification for two parabens using high performance liquid chromatography. Both, instrumental and method LOQs were estimated and compared. The results indicated that the measured LOQs were not equal and varied by a factor of 10 for the different techniques. The lowest LOQ values (0.12-0.17 mg/L) were obtained by linear regression method, the highest (0.81-1.72 mg/L) – based on Eurachem guidelines. It is therefore important to have clearly described procedure for measuring the LOQ during validation to allow interlaboratory comparison. In our opinion, the best approach was a methodology based on signal-to noise ratio."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD20217431&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:20217431/20217431.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Nustatymo ribos matavimo būdų skysčių chromatografijoje palyginimas /","Comparison of the approaches to estimate limit of quantification in liquid chromatography."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:43:09Z"}