{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:20295717"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:20295717","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Skaičiavimų lygiagretinimas naudojant išreikštines skirtumines schemas /","abstract":"Operation of biosensor is described with mathematical model, which by applying explicit differential schemes is transformed to numerical model. Calculations of numerical model are performed using computers. To get high accuracy of numerical model, highly detailed calculations must be made and this process takes long time. To make this process faster parallel computations can be applied to numerical model. Calculations presented in this paper were used to model amperometric biosensor. The purpose of this paper was to apply parallel calculations using explicit finite differential schemes while implementing parallel algorithm for graphics processing unit. After completing calculations recommendatory findings were presented in which it was stated with what step count what thread number it is most optimal to use. After examining parallel algorithm application possibilities while modeling biosensors, calculations results were presented in wich it is possible to see that parallel algorithm becomes effective when step count is higher than 2000. General purpose computing on graphics processing unit were implemented in NVIDIA graphics cards with NVIDIA CUDA compute platform. Examination of the implemented algorithm proved that parallelization of calculations can be used to efficiently model biosensors.","abstract_html":"Operation of biosensor is described with mathematical model, which by applying explicit differential schemes is transformed to numerical model. Calculations of numerical model are performed using computers. To get high accuracy of numerical model, highly detailed calculations must be made and this process takes long time. To make this process faster parallel computations can be applied to numerical model. Calculations presented in this paper were used to model amperometric biosensor. The purpose of this paper was to apply parallel calculations using explicit finite differential schemes while implementing parallel algorithm for graphics processing unit. After completing calculations recommendatory findings were presented in which it was stated with what step count what thread number it is most optimal to use. After examining parallel algorithm application possibilities while modeling biosensors, calculations results were presented in wich it is possible to see that parallel algorithm becomes effective when step count is higher than 2000. General purpose computing on graphics processing unit were implemented in NVIDIA graphics cards with NVIDIA CUDA compute platform. Examination of the implemented algorithm proved that parallelization of calculations can be used to efficiently model biosensors.","abstract_has_math":false,"creators":["Stonikas, Edvinas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Ašeris, Vytautas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T09:43:09Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD20295717&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD20295717&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A20295717","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ašeris, Vytautas"]},{"key":"dc:creator","label":"Author","values":["Stonikas, Edvinas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:20295717/20295717.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD20295717&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Operation of biosensor is described with mathematical model, which by applying explicit differential schemes is transformed to numerical model. Calculations of numerical model are performed using computers. To get high accuracy of numerical model, highly detailed calculations must be made and this process takes long time. To make this process faster parallel computations can be applied to numerical model. Calculations presented in this paper were used to model amperometric biosensor. The purpose of this paper was to apply parallel calculations using explicit finite differential schemes while implementing parallel algorithm for graphics processing unit. After completing calculations recommendatory findings were presented in which it was stated with what step count what thread number it is most optimal to use. After examining parallel algorithm application possibilities while modeling biosensors, calculations results were presented in wich it is possible to see that parallel algorithm becomes effective when step count is higher than 2000. General purpose computing on graphics processing unit were implemented in NVIDIA graphics cards with NVIDIA CUDA compute platform. Examination of the implemented algorithm proved that parallelization of calculations can be used to efficiently model biosensors."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Skaičiavimų lygiagretinimas naudojant išreikštines skirtumines schemas /","Parallelization of calculations using the explicit difference schemes."]}]}],"canonical_facts":{"dc:contributor":["Ašeris, Vytautas"],"dc:creator":["Stonikas, Edvinas,"],"dc:date":["2016"],"dc:description":["Operation of biosensor is described with mathematical model, which by applying explicit differential schemes is transformed to numerical model. Calculations of numerical model are performed using computers. To get high accuracy of numerical model, highly detailed calculations must be made and this process takes long time. To make this process faster parallel computations can be applied to numerical model. Calculations presented in this paper were used to model amperometric biosensor. The purpose of this paper was to apply parallel calculations using explicit finite differential schemes while implementing parallel algorithm for graphics processing unit. After completing calculations recommendatory findings were presented in which it was stated with what step count what thread number it is most optimal to use. After examining parallel algorithm application possibilities while modeling biosensors, calculations results were presented in wich it is possible to see that parallel algorithm becomes effective when step count is higher than 2000. General purpose computing on graphics processing unit were implemented in NVIDIA graphics cards with NVIDIA CUDA compute platform. Examination of the implemented algorithm proved that parallelization of calculations can be used to efficiently model biosensors."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD20295717&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:20295717/20295717.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Skaičiavimų lygiagretinimas naudojant išreikštines skirtumines schemas /","Parallelization of calculations using the explicit difference schemes."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:43:09Z"}