{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:2107896"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:2107896","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Saugos elektros tinkle įvertinimo laboratorinis stendas /","abstract":"The laboratory kit for safety evaluation in electrical network was created and installed in this final bachelor thesis. According to the safety conditions and requirements, the electrical equipment was selected. Network’s and human’s protection against electrical system was designed using modern technologies. Principal electrical and layout schemes of laboratory kit were drawn. The reasearch was conducted of a danger in IT, TT, TN-C, TN-S electrical network. At the time of research the electrical network was analysed in emergency modes and the human's level of risk was investigated while operating electrical equipment with defects. The electrical equipment for safety evaluation kit was selected and described in this project: voltage switch, overcurrent protection, residual-current device protection, variable C and N wire resistance, variable neutral and local earth ground resistance, variable wire insulation resistance, currents cut-off stopwatch, voltage measuring device, short circuit button, installation wiring selection.","abstract_html":"The laboratory kit for safety evaluation in electrical network was created and installed in this final bachelor thesis. According to the safety conditions and requirements, the electrical equipment was selected. Network’s and human’s protection against electrical system was designed using modern technologies. Principal electrical and layout schemes of laboratory kit were drawn. The reasearch was conducted of a danger in IT, TT, TN-C, TN-S electrical network. At the time of research the electrical network was analysed in emergency modes and the human&#x27;s level of risk was investigated while operating electrical equipment with defects. The electrical equipment for safety evaluation kit was selected and described in this project: voltage switch, overcurrent protection, residual-current device protection, variable C and N wire resistance, variable neutral and local earth ground resistance, variable wire insulation resistance, currents cut-off stopwatch, voltage measuring device, short circuit button, installation wiring selection.","abstract_has_math":false,"creators":["Jasaitis, Mintaras,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Buivis, Leonardas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-19T09:58:37Z","subjects":["Laboratory ; kit ; human ; safety"],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD2107896&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD2107896&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A2107896","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Buivis, Leonardas"]},{"key":"dc:creator","label":"Author","values":["Jasaitis, Mintaras,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:2107896/2107896.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Laboratory ; kit ; human ; safety"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD2107896&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The laboratory kit for safety evaluation in electrical network was created and installed in this final bachelor thesis. According to the safety conditions and requirements, the electrical equipment was selected. Network’s and human’s protection against electrical system was designed using modern technologies. Principal electrical and layout schemes of laboratory kit were drawn. The reasearch was conducted of a danger in IT, TT, TN-C, TN-S electrical network. At the time of research the electrical network was analysed in emergency modes and the human's level of risk was investigated while operating electrical equipment with defects. The electrical equipment for safety evaluation kit was selected and described in this project: voltage switch, overcurrent protection, residual-current device protection, variable C and N wire resistance, variable neutral and local earth ground resistance, variable wire insulation resistance, currents cut-off stopwatch, voltage measuring device, short circuit button, installation wiring selection."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Saugos elektros tinkle įvertinimo laboratorinis stendas /","Laboratory kit for safety evaluation in electrical network."]}]}],"canonical_facts":{"dc:contributor":["Buivis, Leonardas"],"dc:creator":["Jasaitis, Mintaras,"],"dc:date":["2013"],"dc:description":["The laboratory kit for safety evaluation in electrical network was created and installed in this final bachelor thesis. According to the safety conditions and requirements, the electrical equipment was selected. Network’s and human’s protection against electrical system was designed using modern technologies. Principal electrical and layout schemes of laboratory kit were drawn. The reasearch was conducted of a danger in IT, TT, TN-C, TN-S electrical network. At the time of research the electrical network was analysed in emergency modes and the human's level of risk was investigated while operating electrical equipment with defects. The electrical equipment for safety evaluation kit was selected and described in this project: voltage switch, overcurrent protection, residual-current device protection, variable C and N wire resistance, variable neutral and local earth ground resistance, variable wire insulation resistance, currents cut-off stopwatch, voltage measuring device, short circuit button, installation wiring selection."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD2107896&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:2107896/2107896.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["Laboratory ; kit ; human ; safety"],"dc:title":["Saugos elektros tinkle įvertinimo laboratorinis stendas /","Laboratory kit for safety evaluation in electrical network."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:58:37Z"}