{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:2111799"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:2111799","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Dirbtinių ašarų optinių savybių tyrimas /","abstract":"The analysis describes characteristics of natural tears, dry eyes syndromes, their causes and treatment. The benefit of artificial tears, their types, usage, composition are described here. Wider examination is done on chemical and physical characteristics of artificial tears. A principle of light's absorption, spectrums, principles of Buger and Lambert are introduced as well as operating principles of spectrophotometer and refractometer. The refractive index of artificial tears different types and optical permeability are investigated by experimental research and analysis of spectral curves is done. Artificial tears for this analysis were selected randomly. Spectral permeability was measured three times. The aim of experimental research was to find out weather just opened and before their expiration date artificial tears absorb UV rays and weather their spectral permeability change over time. Analysis results of artificial tears permeability for UV rays are reviewed. Conclusions are done and list of references are presented at the end of work.","abstract_html":"The analysis describes characteristics of natural tears, dry eyes syndromes, their causes and treatment. The benefit of artificial tears, their types, usage, composition are described here. Wider examination is done on chemical and physical characteristics of artificial tears. A principle of light&#x27;s absorption, spectrums, principles of Buger and Lambert are introduced as well as operating principles of spectrophotometer and refractometer. The refractive index of artificial tears different types and optical permeability are investigated by experimental research and analysis of spectral curves is done. Artificial tears for this analysis were selected randomly. Spectral permeability was measured three times. The aim of experimental research was to find out weather just opened and before their expiration date artificial tears absorb UV rays and weather their spectral permeability change over time. Analysis results of artificial tears permeability for UV rays are reviewed. Conclusions are done and list of references are presented at the end of work.","abstract_has_math":false,"creators":["Kutyš, Dana,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Pelanskienė, Aurelija"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-19T09:58:42Z","subjects":["artificial tears ; dry eyes syndromes ; physical characteristics"],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD2111799&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD2111799&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A2111799","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Pelanskienė, Aurelija"]},{"key":"dc:creator","label":"Author","values":["Kutyš, Dana,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:2111799/2111799.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["artificial tears ; dry eyes syndromes ; physical characteristics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD2111799&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The analysis describes characteristics of natural tears, dry eyes syndromes, their causes and treatment. The benefit of artificial tears, their types, usage, composition are described here. Wider examination is done on chemical and physical characteristics of artificial tears. A principle of light's absorption, spectrums, principles of Buger and Lambert are introduced as well as operating principles of spectrophotometer and refractometer. The refractive index of artificial tears different types and optical permeability are investigated by experimental research and analysis of spectral curves is done. Artificial tears for this analysis were selected randomly. Spectral permeability was measured three times. The aim of experimental research was to find out weather just opened and before their expiration date artificial tears absorb UV rays and weather their spectral permeability change over time. Analysis results of artificial tears permeability for UV rays are reviewed. Conclusions are done and list of references are presented at the end of work."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Dirbtinių ašarų optinių savybių tyrimas /","The investigation of the optical properties of artificial tears."]}]}],"canonical_facts":{"dc:contributor":["Pelanskienė, Aurelija"],"dc:creator":["Kutyš, Dana,"],"dc:date":["2013"],"dc:description":["The analysis describes characteristics of natural tears, dry eyes syndromes, their causes and treatment. The benefit of artificial tears, their types, usage, composition are described here. Wider examination is done on chemical and physical characteristics of artificial tears. A principle of light's absorption, spectrums, principles of Buger and Lambert are introduced as well as operating principles of spectrophotometer and refractometer. The refractive index of artificial tears different types and optical permeability are investigated by experimental research and analysis of spectral curves is done. Artificial tears for this analysis were selected randomly. Spectral permeability was measured three times. The aim of experimental research was to find out weather just opened and before their expiration date artificial tears absorb UV rays and weather their spectral permeability change over time. Analysis results of artificial tears permeability for UV rays are reviewed. Conclusions are done and list of references are presented at the end of work."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD2111799&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:2111799/2111799.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["artificial tears ; dry eyes syndromes ; physical characteristics"],"dc:title":["Dirbtinių ašarų optinių savybių tyrimas /","The investigation of the optical properties of artificial tears."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T09:58:42Z"}