{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:229556294"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:229556294","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Taikomoji programa skirta epilepsijos priepuolių paieškai dirbtinio intelekto metodais /","abstract":"The aim of this bachelor thesis is to develop an application for neurologists and neurophysiologists to speed up their work with electroencephalography (EEG) test results. The application uses EfficientNetV2, a convolutional neural network (CNN) architecture that automatically flags possible epileptic seizures in the EEG. The model was trained using the Siena Scalp EEG database, which consists of EEG recordings from 14 patients. The application reduces the analysis time for neurologists: instead of evaluating the entire EEG study, neurologists review only selected segments. The model achieved 79.01% accuracy, 89.09% sensitivity and 78.94% specificity. A different version of the model (seizure duration must be at least 15 seconds) is also available in the application and achieves 92.43% accuracy, 72.73% sensitivity and 92.57% specificity. The application could be used in the internal infrastructure of medical institutions.","abstract_html":"The aim of this bachelor thesis is to develop an application for neurologists and neurophysiologists to speed up their work with electroencephalography (EEG) test results. The application uses EfficientNetV2, a convolutional neural network (CNN) architecture that automatically flags possible epileptic seizures in the EEG. The model was trained using the Siena Scalp EEG database, which consists of EEG recordings from 14 patients. The application reduces the analysis time for neurologists: instead of evaluating the entire EEG study, neurologists review only selected segments. The model achieved 79.01% accuracy, 89.09% sensitivity and 78.94% specificity. A different version of the model (seizure duration must be at least 15 seconds) is also available in the application and achieves 92.43% accuracy, 72.73% sensitivity and 92.57% specificity. The application could be used in the internal infrastructure of medical institutions.","abstract_has_math":false,"creators":["Vidžiūnas, Arnas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T10:03:38Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD229556294&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD229556294&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A229556294","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Vidžiūnas, Arnas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:229556294/229556294.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD229556294&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The aim of this bachelor thesis is to develop an application for neurologists and neurophysiologists to speed up their work with electroencephalography (EEG) test results. The application uses EfficientNetV2, a convolutional neural network (CNN) architecture that automatically flags possible epileptic seizures in the EEG. The model was trained using the Siena Scalp EEG database, which consists of EEG recordings from 14 patients. The application reduces the analysis time for neurologists: instead of evaluating the entire EEG study, neurologists review only selected segments. The model achieved 79.01% accuracy, 89.09% sensitivity and 78.94% specificity. A different version of the model (seizure duration must be at least 15 seconds) is also available in the application and achieves 92.43% accuracy, 72.73% sensitivity and 92.57% specificity. The application could be used in the internal infrastructure of medical institutions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Taikomoji programa skirta epilepsijos priepuolių paieškai dirbtinio intelekto metodais /","Application for detecting epileptic seizures using artificial intelligence methods."]}]}],"canonical_facts":{"dc:creator":["Vidžiūnas, Arnas,"],"dc:date":["2025"],"dc:description":["The aim of this bachelor thesis is to develop an application for neurologists and neurophysiologists to speed up their work with electroencephalography (EEG) test results. The application uses EfficientNetV2, a convolutional neural network (CNN) architecture that automatically flags possible epileptic seizures in the EEG. The model was trained using the Siena Scalp EEG database, which consists of EEG recordings from 14 patients. The application reduces the analysis time for neurologists: instead of evaluating the entire EEG study, neurologists review only selected segments. The model achieved 79.01% accuracy, 89.09% sensitivity and 78.94% specificity. A different version of the model (seizure duration must be at least 15 seconds) is also available in the application and achieves 92.43% accuracy, 72.73% sensitivity and 92.57% specificity. The application could be used in the internal infrastructure of medical institutions."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD229556294&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:229556294/229556294.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Taikomoji programa skirta epilepsijos priepuolių paieškai dirbtinio intelekto metodais /","Application for detecting epileptic seizures using artificial intelligence methods."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:03:38Z"}