{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:238869870"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:238869870","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Legs length discrepancy after hip replacement for femoral neck fracture /","abstract":"Leg length discrepancy (LLD) is a common and often challenging complication after total hip arthroplasty (THA) or hemiarthroplasty (HA) for femoral neck fractures (FNF), leading to issues such as gait problems, back pain, and sometimes the need for further surgery. This thesis presents a narrative literature review exploring the anatomical, surgical, and technological factors contributing to LLD. Key determinants include preoperative skeletal asymmetry, surgical approach, implant selection, and intraoperative technique. Comparative analysis highlights that cemented implants generally offer better short-term stability and fewer complications than uncemented ones, though neither guarantees LLD prevention. Advances such as computer-assisted surgery and intraoperative fluoroscopy have improved leg length accuracy. The study emphasizes that individualized preoperative planning and precise intraoperative execution are essential to minimizing LLD and optimizing functional outcomes in FNF patients undergoing hip replacement.","abstract_html":"Leg length discrepancy (LLD) is a common and often challenging complication after total hip arthroplasty (THA) or hemiarthroplasty (HA) for femoral neck fractures (FNF), leading to issues such as gait problems, back pain, and sometimes the need for further surgery. This thesis presents a narrative literature review exploring the anatomical, surgical, and technological factors contributing to LLD. Key determinants include preoperative skeletal asymmetry, surgical approach, implant selection, and intraoperative technique. Comparative analysis highlights that cemented implants generally offer better short-term stability and fewer complications than uncemented ones, though neither guarantees LLD prevention. Advances such as computer-assisted surgery and intraoperative fluoroscopy have improved leg length accuracy. The study emphasizes that individualized preoperative planning and precise intraoperative execution are essential to minimizing LLD and optimizing functional outcomes in FNF patients undergoing hip replacement.","abstract_has_math":false,"creators":["Henle, Cornelius Carl Constantin,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T10:02:29Z","subjects":["Femoral neck fracture, Total Hip Arthroplasty, Hemiarthroplasty, Leg Length Discrepancy, Surgical Approaches, Cemented and Uncemented, Intraoperative Measurement, Robotic-Assisted THA"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD238869870&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD238869870&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A238869870","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Henle, Cornelius Carl Constantin,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:238869870/238869870.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/masterThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Femoral neck fracture, Total Hip Arthroplasty, Hemiarthroplasty, Leg Length Discrepancy, Surgical Approaches, Cemented and Uncemented, Intraoperative Measurement, Robotic-Assisted THA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD238869870&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Leg length discrepancy (LLD) is a common and often challenging complication after total hip arthroplasty (THA) or hemiarthroplasty (HA) for femoral neck fractures (FNF), leading to issues such as gait problems, back pain, and sometimes the need for further surgery. This thesis presents a narrative literature review exploring the anatomical, surgical, and technological factors contributing to LLD. Key determinants include preoperative skeletal asymmetry, surgical approach, implant selection, and intraoperative technique. Comparative analysis highlights that cemented implants generally offer better short-term stability and fewer complications than uncemented ones, though neither guarantees LLD prevention. Advances such as computer-assisted surgery and intraoperative fluoroscopy have improved leg length accuracy. The study emphasizes that individualized preoperative planning and precise intraoperative execution are essential to minimizing LLD and optimizing functional outcomes in FNF patients undergoing hip replacement."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Legs length discrepancy after hip replacement for femoral neck fracture /","Legs Length Discrepancy After Hip Replacement for Femoral Neck Fracture."]}]}],"canonical_facts":{"dc:creator":["Henle, Cornelius Carl Constantin,"],"dc:date":["2025"],"dc:description":["Leg length discrepancy (LLD) is a common and often challenging complication after total hip arthroplasty (THA) or hemiarthroplasty (HA) for femoral neck fractures (FNF), leading to issues such as gait problems, back pain, and sometimes the need for further surgery. This thesis presents a narrative literature review exploring the anatomical, surgical, and technological factors contributing to LLD. Key determinants include preoperative skeletal asymmetry, surgical approach, implant selection, and intraoperative technique. Comparative analysis highlights that cemented implants generally offer better short-term stability and fewer complications than uncemented ones, though neither guarantees LLD prevention. Advances such as computer-assisted surgery and intraoperative fluoroscopy have improved leg length accuracy. The study emphasizes that individualized preoperative planning and precise intraoperative execution are essential to minimizing LLD and optimizing functional outcomes in FNF patients undergoing hip replacement."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD238869870&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:238869870/238869870.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["Femoral neck fracture, Total Hip Arthroplasty, Hemiarthroplasty, Leg Length Discrepancy, Surgical Approaches, Cemented and Uncemented, Intraoperative Measurement, Robotic-Assisted THA"],"dc:title":["Legs length discrepancy after hip replacement for femoral neck fracture /","Legs Length Discrepancy After Hip Replacement for Femoral Neck Fracture."],"dc:type":["info:eu-repo/semantics/masterThesis"]},"updated_at":"2026-11-19T10:02:29Z"}