{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:239028201"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:239028201","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Elektrocheminio biojutiklio, naudojant D-aminorugščių oksidazę, tyrimas /","abstract":"In this paper, an electrochemical biosensor for D-tryptophan determination was developed using D-amino acid oxidase (DAAO). Considering the increasing need to rapidly and selectively detect D-amino acids in various biological samples, this study aimed to create a first-generation enzymatic biosensor based on molecular oxygen as the natural electron acceptor. In the biosensor fabrication, DAAO and catalase (CAT) were immobilized on gold electrodes coated with gold nanoparticles (AuNP) to increase the electrode surface area, and additionally covered with a poly-norepinephrine (PoliNE) layer, which ensures sensitivity to changes in oxygen concentration. The interaction of the enzymes was exploited to strengthen the signal – DAAO oxidized D-tryptophan, generating hydrogen peroxide, which catalase decomposed into water and oxygen, thus ensuring a constant oxygen supply for DAAO activity and enhancing the biosensor’s electrochemical respon-se. During the study, comprehensive electrochemical analysis was performed using cyclic vol-tammetry and chronoamperometry, the sensitivity, detection limit (LOD), selectivity against other amino acids, and stability of the developed biosensor were assessed. The biosensor can respond to other D-amino acids but does not respond to metabolites present in biological samples. The de-tection limit was 8.327 µM D-tryptophan concentration, but the biosensor is not stable.","abstract_html":"In this paper, an electrochemical biosensor for D-tryptophan determination was developed using D-amino acid oxidase (DAAO). Considering the increasing need to rapidly and selectively detect D-amino acids in various biological samples, this study aimed to create a first-generation enzymatic biosensor based on molecular oxygen as the natural electron acceptor. In the biosensor fabrication, DAAO and catalase (CAT) were immobilized on gold electrodes coated with gold nanoparticles (AuNP) to increase the electrode surface area, and additionally covered with a poly-norepinephrine (PoliNE) layer, which ensures sensitivity to changes in oxygen concentration. The interaction of the enzymes was exploited to strengthen the signal – DAAO oxidized D-tryptophan, generating hydrogen peroxide, which catalase decomposed into water and oxygen, thus ensuring a constant oxygen supply for DAAO activity and enhancing the biosensor’s electrochemical respon-se. During the study, comprehensive electrochemical analysis was performed using cyclic vol-tammetry and chronoamperometry, the sensitivity, detection limit (LOD), selectivity against other amino acids, and stability of the developed biosensor were assessed. The biosensor can respond to other D-amino acids but does not respond to metabolites present in biological samples. The de-tection limit was 8.327 µM D-tryptophan concentration, but the biosensor is not stable.","abstract_has_math":false,"creators":["Daukšas, Adomas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T10:03:32Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD239028201&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD239028201&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A239028201","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Daukšas, Adomas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:239028201/239028201.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD239028201&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this paper, an electrochemical biosensor for D-tryptophan determination was developed using D-amino acid oxidase (DAAO). Considering the increasing need to rapidly and selectively detect D-amino acids in various biological samples, this study aimed to create a first-generation enzymatic biosensor based on molecular oxygen as the natural electron acceptor. In the biosensor fabrication, DAAO and catalase (CAT) were immobilized on gold electrodes coated with gold nanoparticles (AuNP) to increase the electrode surface area, and additionally covered with a poly-norepinephrine (PoliNE) layer, which ensures sensitivity to changes in oxygen concentration. The interaction of the enzymes was exploited to strengthen the signal – DAAO oxidized D-tryptophan, generating hydrogen peroxide, which catalase decomposed into water and oxygen, thus ensuring a constant oxygen supply for DAAO activity and enhancing the biosensor’s electrochemical respon-se. During the study, comprehensive electrochemical analysis was performed using cyclic vol-tammetry and chronoamperometry, the sensitivity, detection limit (LOD), selectivity against other amino acids, and stability of the developed biosensor were assessed. The biosensor can respond to other D-amino acids but does not respond to metabolites present in biological samples. The de-tection limit was 8.327 µM D-tryptophan concentration, but the biosensor is not stable."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Elektrocheminio biojutiklio, naudojant D-aminorugščių oksidazę, tyrimas /","Sudy of electrochemical biosensor using d-amino acid oxidase."]}]}],"canonical_facts":{"dc:creator":["Daukšas, Adomas,"],"dc:date":["2025"],"dc:description":["In this paper, an electrochemical biosensor for D-tryptophan determination was developed using D-amino acid oxidase (DAAO). Considering the increasing need to rapidly and selectively detect D-amino acids in various biological samples, this study aimed to create a first-generation enzymatic biosensor based on molecular oxygen as the natural electron acceptor. In the biosensor fabrication, DAAO and catalase (CAT) were immobilized on gold electrodes coated with gold nanoparticles (AuNP) to increase the electrode surface area, and additionally covered with a poly-norepinephrine (PoliNE) layer, which ensures sensitivity to changes in oxygen concentration. The interaction of the enzymes was exploited to strengthen the signal – DAAO oxidized D-tryptophan, generating hydrogen peroxide, which catalase decomposed into water and oxygen, thus ensuring a constant oxygen supply for DAAO activity and enhancing the biosensor’s electrochemical respon-se. During the study, comprehensive electrochemical analysis was performed using cyclic vol-tammetry and chronoamperometry, the sensitivity, detection limit (LOD), selectivity against other amino acids, and stability of the developed biosensor were assessed. The biosensor can respond to other D-amino acids but does not respond to metabolites present in biological samples. The de-tection limit was 8.327 µM D-tryptophan concentration, but the biosensor is not stable."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD239028201&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:239028201/239028201.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Elektrocheminio biojutiklio, naudojant D-aminorugščių oksidazę, tyrimas /","Sudy of electrochemical biosensor using d-amino acid oxidase."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:03:32Z"}