{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:262241205"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:262241205","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Biomaterials research in the field of biocompatibility, cell adhesion, and applications in microfluidic systems /","abstract":"The surface properties of biomaterials determine their interaction with cells and are crucial for ensuring their suitability for biomedical applications. This dissertation analyses surface modification strategies applied to two distinct classes of materials: anodized aluminum (Al) alloy 6082 and polycarbonate (PC). It evaluates the impact of these modifications on cell adhesion, biocompatibility, and biomedical applicability. The Al alloy, anodized using sulfuric and phosphoric acid electrolytes, was examined to assess whether the resulting samples meet the requirements for biomaterials. The data revealed that only the alloy anodized with sulfuric acid electrolyte exhibits the appropriate chemical stability, surface morphology, and cell adhesion, qualifying it as a biomaterial. Meanwhile, although PC is classified as a biomaterial, it is inherently unsuitable for cell adhesion due to its hydrophobic nature. To facilitate mammalian cell adhesion, its surface was chemically modified for compatibility with microfluidic systems. A microphysiological system was developed, integrating a porous PC membrane, electrodes, and microenvironment sensors, designed for use with mammalian cells. This dissertation demonstrates that surface modification can be purposefully applied to enhance cell interaction and adapt materials for specific biomedical needs, such as implantology, tissue engineering, and in vitro microfluidic technologies.","abstract_html":"The surface properties of biomaterials determine their interaction with cells and are crucial for ensuring their suitability for biomedical applications. This dissertation analyses surface modification strategies applied to two distinct classes of materials: anodized aluminum (Al) alloy 6082 and polycarbonate (PC). It evaluates the impact of these modifications on cell adhesion, biocompatibility, and biomedical applicability. The Al alloy, anodized using sulfuric and phosphoric acid electrolytes, was examined to assess whether the resulting samples meet the requirements for biomaterials. The data revealed that only the alloy anodized with sulfuric acid electrolyte exhibits the appropriate chemical stability, surface morphology, and cell adhesion, qualifying it as a biomaterial. Meanwhile, although PC is classified as a biomaterial, it is inherently unsuitable for cell adhesion due to its hydrophobic nature. To facilitate mammalian cell adhesion, its surface was chemically modified for compatibility with microfluidic systems. A microphysiological system was developed, integrating a porous PC membrane, electrodes, and microenvironment sensors, designed for use with mammalian cells. This dissertation demonstrates that surface modification can be purposefully applied to enhance cell interaction and adapt materials for specific biomedical needs, such as implantology, tissue engineering, and in vitro microfluidic technologies.","abstract_has_math":false,"creators":["Bakutė, Neringa,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Stirkė, Arūnas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T10:11:11Z","subjects":["Al 6082 alloy ; policarbonate, cell adhesion ; microphysiological system ; Organ-on-Chip"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD262241205&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD262241205&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A262241205","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stirkė, Arūnas"]},{"key":"dc:creator","label":"Author","values":["Bakutė, Neringa,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["info:eu-repo/semantics/altIdentifier/doi/10.15388/vu.thesis.874","https://epublications.vu.lt/object/elaba:262241205/262241205.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/doctoralThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Al 6082 alloy ; policarbonate, cell adhesion ; microphysiological system ; Organ-on-Chip"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD262241205&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The surface properties of biomaterials determine their interaction with cells and are crucial for ensuring their suitability for biomedical applications. This dissertation analyses surface modification strategies applied to two distinct classes of materials: anodized aluminum (Al) alloy 6082 and polycarbonate (PC). It evaluates the impact of these modifications on cell adhesion, biocompatibility, and biomedical applicability. The Al alloy, anodized using sulfuric and phosphoric acid electrolytes, was examined to assess whether the resulting samples meet the requirements for biomaterials. The data revealed that only the alloy anodized with sulfuric acid electrolyte exhibits the appropriate chemical stability, surface morphology, and cell adhesion, qualifying it as a biomaterial. Meanwhile, although PC is classified as a biomaterial, it is inherently unsuitable for cell adhesion due to its hydrophobic nature. To facilitate mammalian cell adhesion, its surface was chemically modified for compatibility with microfluidic systems. A microphysiological system was developed, integrating a porous PC membrane, electrodes, and microenvironment sensors, designed for use with mammalian cells. This dissertation demonstrates that surface modification can be purposefully applied to enhance cell interaction and adapt materials for specific biomedical needs, such as implantology, tissue engineering, and in vitro microfluidic technologies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Biomaterials research in the field of biocompatibility, cell adhesion, and applications in microfluidic systems /","Biomedžiagų biologinio suderinamumo, ląstelių adhezijos ir jų pritaikymo mikroskysčių sistemose tyrimai."]}]}],"canonical_facts":{"dc:contributor":["Stirkė, Arūnas"],"dc:creator":["Bakutė, Neringa,"],"dc:date":["2025"],"dc:description":["The surface properties of biomaterials determine their interaction with cells and are crucial for ensuring their suitability for biomedical applications. This dissertation analyses surface modification strategies applied to two distinct classes of materials: anodized aluminum (Al) alloy 6082 and polycarbonate (PC). It evaluates the impact of these modifications on cell adhesion, biocompatibility, and biomedical applicability. The Al alloy, anodized using sulfuric and phosphoric acid electrolytes, was examined to assess whether the resulting samples meet the requirements for biomaterials. The data revealed that only the alloy anodized with sulfuric acid electrolyte exhibits the appropriate chemical stability, surface morphology, and cell adhesion, qualifying it as a biomaterial. Meanwhile, although PC is classified as a biomaterial, it is inherently unsuitable for cell adhesion due to its hydrophobic nature. To facilitate mammalian cell adhesion, its surface was chemically modified for compatibility with microfluidic systems. A microphysiological system was developed, integrating a porous PC membrane, electrodes, and microenvironment sensors, designed for use with mammalian cells. This dissertation demonstrates that surface modification can be purposefully applied to enhance cell interaction and adapt materials for specific biomedical needs, such as implantology, tissue engineering, and in vitro microfluidic technologies."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD262241205&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["info:eu-repo/semantics/altIdentifier/doi/10.15388/vu.thesis.874","https://epublications.vu.lt/object/elaba:262241205/262241205.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["Al 6082 alloy ; policarbonate, cell adhesion ; microphysiological system ; Organ-on-Chip"],"dc:title":["Biomaterials research in the field of biocompatibility, cell adhesion, and applications in microfluidic systems /","Biomedžiagų biologinio suderinamumo, ląstelių adhezijos ir jų pritaikymo mikroskysčių sistemose tyrimai."],"dc:type":["info:eu-repo/semantics/doctoralThesis"]},"updated_at":"2026-11-19T10:11:11Z"}