{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308117025"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308117025","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Characterization of nitrogen-vacancy centers in diamond for magnetometry /","abstract":"This thesis investigates nitrogen-vacancy centers in diamond for magnetic-field sensing. Three samples were studied: a microdiamond, a &#10216;111&#10217; bulk diamond, and a &#10216;100&#10217; bulk diamond. The samples were characterized using continuous-wave ODMR, polarization-dependent ODMR, pulsed spin-control measurements, and lock-in-based magnetic-field readout. Zero-field and magnetic-field-dependent ODMR measurements confirmed the expected NV resonance behaviour and showed differences between the samples caused by strain, orientation, linewidth, and contrast. The best estimated shot-noise-limited sensitivity was obtained for the &#10216;100&#10217; bulk diamond, reaching approximately 10.21 nT/&#8730;Hz using the maximum-slope method. Pulsed measurements showed the longest relaxation and coherence times for the &#10216;111&#10217; bulk diamond, with T1=9.53 ms and T2=2375 ns. Lock-in-based readout was used to detect weak oscillating magnetic fields down to approximately 70 nT.","abstract_html":"This thesis investigates nitrogen-vacancy centers in diamond for magnetic-field sensing. Three samples were studied: a microdiamond, a &amp;#10216;111&amp;#10217; bulk diamond, and a &amp;#10216;100&amp;#10217; bulk diamond. The samples were characterized using continuous-wave ODMR, polarization-dependent ODMR, pulsed spin-control measurements, and lock-in-based magnetic-field readout. Zero-field and magnetic-field-dependent ODMR measurements confirmed the expected NV resonance behaviour and showed differences between the samples caused by strain, orientation, linewidth, and contrast. The best estimated shot-noise-limited sensitivity was obtained for the &amp;#10216;100&amp;#10217; bulk diamond, reaching approximately 10.21 nT/&amp;#8730;Hz using the maximum-slope method. Pulsed measurements showed the longest relaxation and coherence times for the &amp;#10216;111&amp;#10217; bulk diamond, with T1=9.53 ms and T2=2375 ns. Lock-in-based readout was used to detect weak oscillating magnetic fields down to approximately 70 nT.","abstract_has_math":false,"creators":["Šilys, Vakaris,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:11:35Z","subjects":["nitrogen-vacancy centers, diamond magnetometry, optically detected magnetic resonance"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308117025&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308117025&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avilnius%3Aoai%3Avu.lt%3Aelaba%3A308117025","prefix":"oai_dc"},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308117025","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Šilys, Vakaris,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["nitrogen-vacancy centers, diamond magnetometry, optically detected magnetic resonance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308117025&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis investigates nitrogen-vacancy centers in diamond for magnetic-field sensing. Three samples were studied: a microdiamond, a &#10216;111&#10217; bulk diamond, and a &#10216;100&#10217; bulk diamond. The samples were characterized using continuous-wave ODMR, polarization-dependent ODMR, pulsed spin-control measurements, and lock-in-based magnetic-field readout. Zero-field and magnetic-field-dependent ODMR measurements confirmed the expected NV resonance behaviour and showed differences between the samples caused by strain, orientation, linewidth, and contrast. The best estimated shot-noise-limited sensitivity was obtained for the &#10216;100&#10217; bulk diamond, reaching approximately 10.21 nT/&#8730;Hz using the maximum-slope method. Pulsed measurements showed the longest relaxation and coherence times for the &#10216;111&#10217; bulk diamond, with T1=9.53 ms and T2=2375 ns. Lock-in-based readout was used to detect weak oscillating magnetic fields down to approximately 70 nT."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of nitrogen-vacancy centers in diamond for magnetometry /","Azoto-vakansijų (NV) centrų deimante savybių tyrimas ir charakterizavimas magnetinio lauko matavimams."]}]}],"canonical_facts":{"dc:creator":["Šilys, Vakaris,"],"dc:date":["2026"],"dc:description":["This thesis investigates nitrogen-vacancy centers in diamond for magnetic-field sensing. Three samples were studied: a microdiamond, a &#10216;111&#10217; bulk diamond, and a &#10216;100&#10217; bulk diamond. The samples were characterized using continuous-wave ODMR, polarization-dependent ODMR, pulsed spin-control measurements, and lock-in-based magnetic-field readout. Zero-field and magnetic-field-dependent ODMR measurements confirmed the expected NV resonance behaviour and showed differences between the samples caused by strain, orientation, linewidth, and contrast. The best estimated shot-noise-limited sensitivity was obtained for the &#10216;100&#10217; bulk diamond, reaching approximately 10.21 nT/&#8730;Hz using the maximum-slope method. Pulsed measurements showed the longest relaxation and coherence times for the &#10216;111&#10217; bulk diamond, with T1=9.53 ms and T2=2375 ns. Lock-in-based readout was used to detect weak oscillating magnetic fields down to approximately 70 nT."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308117025&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["nitrogen-vacancy centers, diamond magnetometry, optically detected magnetic resonance"],"dc:title":["Characterization of nitrogen-vacancy centers in diamond for magnetometry /","Azoto-vakansijų (NV) centrų deimante savybių tyrimas ir charakterizavimas magnetinio lauko matavimams."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:11:35Z"}