{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308118215"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308118215","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Dalelių rūšiavimo modeliavimas ir testavimas mikrofluidiniame kanale /","abstract":"The aim of this bachelor thesis was to design and experimentally evaluate a microfluidic particle sorting system based on hydrodynamic methods intended for organoid sorting. To achieve this goal the following objectives were set: literature review on microfluidics, sorting methods and chip fabrication techniques; design the chip geometry; analyze the sorting techniques by performing computational fluid dynamics simulations; fabricate the microfluidic chip and assemble the system; experimentally evaluate the sorting efficiency and analyze the results. Two sorting methods were investigated by computational simulations: a Koanda effect based design with an active membrane and a flow rate controlled design with three inlets and two outlets. The second sorting method for experimental realization was chosen due to its higher sorting efficiency and simpler fabrication. For the experimental realization, the system was scaled up to 3×3 mm cross-section and rapeseed oil was used as the working medium, since its kinematic viscosity preserves laminar flow conditions in the enlarged geometry. The chip was fabricated using CNC milling from PMMA. After assembling and testing the system the sorting efficiency was evaluated in four stages. In the first stage, with only the sample channel B active, particles distributed between the two outlets nearly equally – 48.1 ± 12.6 % to channel D and 51.9 ± 12.6 % to channel E, confirming that the system has no bias. In the OFF state &#951;_E with channels A and B active, sorting efficiency reached 98.5 ± 0.4 %. In the ON state with all three inlets active &#951;_D reached 77.2 ± 4.2 % and when channel A was turned off while B and C channels were working &#951;_D reached 90.9 ± 3.4 % efficiency, indicating that the sheath flow may disturb the sample trajectory and in the future it would be worth considering creating a system where both channels are turned off and on simultaneously for better efficiency.","abstract_html":"The aim of this bachelor thesis was to design and experimentally evaluate a microfluidic particle sorting system based on hydrodynamic methods intended for organoid sorting. To achieve this goal the following objectives were set: literature review on microfluidics, sorting methods and chip fabrication techniques; design the chip geometry; analyze the sorting techniques by performing computational fluid dynamics simulations; fabricate the microfluidic chip and assemble the system; experimentally evaluate the sorting efficiency and analyze the results. Two sorting methods were investigated by computational simulations: a Koanda effect based design with an active membrane and a flow rate controlled design with three inlets and two outlets. The second sorting method for experimental realization was chosen due to its higher sorting efficiency and simpler fabrication. For the experimental realization, the system was scaled up to 3×3 mm cross-section and rapeseed oil was used as the working medium, since its kinematic viscosity preserves laminar flow conditions in the enlarged geometry. The chip was fabricated using CNC milling from PMMA. After assembling and testing the system the sorting efficiency was evaluated in four stages. In the first stage, with only the sample channel B active, particles distributed between the two outlets nearly equally – 48.1 ± 12.6 % to channel D and 51.9 ± 12.6 % to channel E, confirming that the system has no bias. In the OFF state &amp;#951;_E with channels A and B active, sorting efficiency reached 98.5 ± 0.4 %. In the ON state with all three inlets active &amp;#951;_D reached 77.2 ± 4.2 % and when channel A was turned off while B and C channels were working &amp;#951;_D reached 90.9 ± 3.4 % efficiency, indicating that the sheath flow may disturb the sample trajectory and in the future it would be worth considering creating a system where both channels are turned off and on simultaneously for better efficiency.","abstract_has_math":false,"creators":["Beniušis, Simonas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:11:35Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308118215&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308118215&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308118215","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Beniušis, Simonas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:308118215/308118215.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308118215&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The aim of this bachelor thesis was to design and experimentally evaluate a microfluidic particle sorting system based on hydrodynamic methods intended for organoid sorting. To achieve this goal the following objectives were set: literature review on microfluidics, sorting methods and chip fabrication techniques; design the chip geometry; analyze the sorting techniques by performing computational fluid dynamics simulations; fabricate the microfluidic chip and assemble the system; experimentally evaluate the sorting efficiency and analyze the results. Two sorting methods were investigated by computational simulations: a Koanda effect based design with an active membrane and a flow rate controlled design with three inlets and two outlets. The second sorting method for experimental realization was chosen due to its higher sorting efficiency and simpler fabrication. For the experimental realization, the system was scaled up to 3×3 mm cross-section and rapeseed oil was used as the working medium, since its kinematic viscosity preserves laminar flow conditions in the enlarged geometry. The chip was fabricated using CNC milling from PMMA. After assembling and testing the system the sorting efficiency was evaluated in four stages. In the first stage, with only the sample channel B active, particles distributed between the two outlets nearly equally – 48.1 ± 12.6 % to channel D and 51.9 ± 12.6 % to channel E, confirming that the system has no bias. In the OFF state &#951;_E with channels A and B active, sorting efficiency reached 98.5 ± 0.4 %. In the ON state with all three inlets active &#951;_D reached 77.2 ± 4.2 % and when channel A was turned off while B and C channels were working &#951;_D reached 90.9 ± 3.4 % efficiency, indicating that the sheath flow may disturb the sample trajectory and in the future it would be worth considering creating a system where both channels are turned off and on simultaneously for better efficiency."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Dalelių rūšiavimo modeliavimas ir testavimas mikrofluidiniame kanale /","Microfluidic channel particle sorting: modeling and testing."]}]}],"canonical_facts":{"dc:creator":["Beniušis, Simonas,"],"dc:date":["2026"],"dc:description":["The aim of this bachelor thesis was to design and experimentally evaluate a microfluidic particle sorting system based on hydrodynamic methods intended for organoid sorting. To achieve this goal the following objectives were set: literature review on microfluidics, sorting methods and chip fabrication techniques; design the chip geometry; analyze the sorting techniques by performing computational fluid dynamics simulations; fabricate the microfluidic chip and assemble the system; experimentally evaluate the sorting efficiency and analyze the results. Two sorting methods were investigated by computational simulations: a Koanda effect based design with an active membrane and a flow rate controlled design with three inlets and two outlets. The second sorting method for experimental realization was chosen due to its higher sorting efficiency and simpler fabrication. For the experimental realization, the system was scaled up to 3×3 mm cross-section and rapeseed oil was used as the working medium, since its kinematic viscosity preserves laminar flow conditions in the enlarged geometry. The chip was fabricated using CNC milling from PMMA. After assembling and testing the system the sorting efficiency was evaluated in four stages. In the first stage, with only the sample channel B active, particles distributed between the two outlets nearly equally – 48.1 ± 12.6 % to channel D and 51.9 ± 12.6 % to channel E, confirming that the system has no bias. In the OFF state &#951;_E with channels A and B active, sorting efficiency reached 98.5 ± 0.4 %. In the ON state with all three inlets active &#951;_D reached 77.2 ± 4.2 % and when channel A was turned off while B and C channels were working &#951;_D reached 90.9 ± 3.4 % efficiency, indicating that the sheath flow may disturb the sample trajectory and in the future it would be worth considering creating a system where both channels are turned off and on simultaneously for better efficiency."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308118215&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:308118215/308118215.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Dalelių rūšiavimo modeliavimas ir testavimas mikrofluidiniame kanale /","Microfluidic channel particle sorting: modeling and testing."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:11:35Z"}