{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308118696"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308118696","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Flow-through detection and imaging in microfluidic systems via application of the fdml laser /","abstract":"This work investigated the applicability of a Fourier-domain mode-locked (FDML) laser as an illumination source for spectro-temporal scanning and asymmetric-detection imaging systems intended for flow-through measurements in microfluidic environments. The objective was to construct and experimentally evaluate an FDML-based spectro-temporal scanning system and assess its suitability for quantitative phase imaging based on the multi-ATOM principle. An FDML laser was constructed using a semiconductor optical amplifier and a fibre Fabry-Perot tunable filter. Stable wavelength sweeping was achieved at a centre wavelength of approximately 1080~nm, with a sweep bandwidth of approximately 11~nm and a sweep frequency of 544~kHz. A simplified spectro-temporal imaging system was also assembled, employing a diffraction grating for spatial wavelength encoding and knife-edge asymmetric detection for phase-gradient measurement. Experiments revealed that the primary limiting factor of the system was strong coherent interference artefacts arising from the high temporal coherence of the FDML source, polarisation instability, and the sensitivity of the optical system to mechanical and thermal perturbations. Although intensity variations correlated with sample position and knife-edge orientation were observed, the reconstructed quantitative phase images were not of sufficient quality for reliable interpretation. The results indicate that FDML lasers are applicable as sources in spectro-temporal scanning systems; however, successful asymmetric-detection quantitative phase imaging requires additional coherence management and suppression of interference artefacts.","abstract_html":"This work investigated the applicability of a Fourier-domain mode-locked (FDML) laser as an illumination source for spectro-temporal scanning and asymmetric-detection imaging systems intended for flow-through measurements in microfluidic environments. The objective was to construct and experimentally evaluate an FDML-based spectro-temporal scanning system and assess its suitability for quantitative phase imaging based on the multi-ATOM principle. An FDML laser was constructed using a semiconductor optical amplifier and a fibre Fabry-Perot tunable filter. Stable wavelength sweeping was achieved at a centre wavelength of approximately 1080~nm, with a sweep bandwidth of approximately 11~nm and a sweep frequency of 544~kHz. A simplified spectro-temporal imaging system was also assembled, employing a diffraction grating for spatial wavelength encoding and knife-edge asymmetric detection for phase-gradient measurement. Experiments revealed that the primary limiting factor of the system was strong coherent interference artefacts arising from the high temporal coherence of the FDML source, polarisation instability, and the sensitivity of the optical system to mechanical and thermal perturbations. Although intensity variations correlated with sample position and knife-edge orientation were observed, the reconstructed quantitative phase images were not of sufficient quality for reliable interpretation. The results indicate that FDML lasers are applicable as sources in spectro-temporal scanning systems; however, successful asymmetric-detection quantitative phase imaging requires additional coherence management and suppression of interference artefacts.","abstract_has_math":false,"creators":["Puškorius, Laurynas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:11:35Z","subjects":["FDML laser (Fourier-domain mode-locked laser) Spectro-temporal imaging Spectral encoding Time-stretch imaging Quantitative phase imaging (QPI) Multi-ATOM"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308118696&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308118696&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308118696","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Puškorius, Laurynas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:308118696/308118696.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FDML laser (Fourier-domain mode-locked laser) Spectro-temporal imaging Spectral encoding Time-stretch imaging Quantitative phase imaging (QPI) Multi-ATOM"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308118696&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work investigated the applicability of a Fourier-domain mode-locked (FDML) laser as an illumination source for spectro-temporal scanning and asymmetric-detection imaging systems intended for flow-through measurements in microfluidic environments. The objective was to construct and experimentally evaluate an FDML-based spectro-temporal scanning system and assess its suitability for quantitative phase imaging based on the multi-ATOM principle. An FDML laser was constructed using a semiconductor optical amplifier and a fibre Fabry-Perot tunable filter. Stable wavelength sweeping was achieved at a centre wavelength of approximately 1080~nm, with a sweep bandwidth of approximately 11~nm and a sweep frequency of 544~kHz. A simplified spectro-temporal imaging system was also assembled, employing a diffraction grating for spatial wavelength encoding and knife-edge asymmetric detection for phase-gradient measurement. Experiments revealed that the primary limiting factor of the system was strong coherent interference artefacts arising from the high temporal coherence of the FDML source, polarisation instability, and the sensitivity of the optical system to mechanical and thermal perturbations. Although intensity variations correlated with sample position and knife-edge orientation were observed, the reconstructed quantitative phase images were not of sufficient quality for reliable interpretation. The results indicate that FDML lasers are applicable as sources in spectro-temporal scanning systems; however, successful asymmetric-detection quantitative phase imaging requires additional coherence management and suppression of interference artefacts."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Flow-through detection and imaging in microfluidic systems via application of the fdml laser /","Pratakumo režimo aptikimas ir vaizdinimas mikrofluidinėse sistemose, pritaikant FDML lazerį."]}]}],"canonical_facts":{"dc:creator":["Puškorius, Laurynas,"],"dc:date":["2026"],"dc:description":["This work investigated the applicability of a Fourier-domain mode-locked (FDML) laser as an illumination source for spectro-temporal scanning and asymmetric-detection imaging systems intended for flow-through measurements in microfluidic environments. The objective was to construct and experimentally evaluate an FDML-based spectro-temporal scanning system and assess its suitability for quantitative phase imaging based on the multi-ATOM principle. An FDML laser was constructed using a semiconductor optical amplifier and a fibre Fabry-Perot tunable filter. Stable wavelength sweeping was achieved at a centre wavelength of approximately 1080~nm, with a sweep bandwidth of approximately 11~nm and a sweep frequency of 544~kHz. A simplified spectro-temporal imaging system was also assembled, employing a diffraction grating for spatial wavelength encoding and knife-edge asymmetric detection for phase-gradient measurement. Experiments revealed that the primary limiting factor of the system was strong coherent interference artefacts arising from the high temporal coherence of the FDML source, polarisation instability, and the sensitivity of the optical system to mechanical and thermal perturbations. Although intensity variations correlated with sample position and knife-edge orientation were observed, the reconstructed quantitative phase images were not of sufficient quality for reliable interpretation. The results indicate that FDML lasers are applicable as sources in spectro-temporal scanning systems; however, successful asymmetric-detection quantitative phase imaging requires additional coherence management and suppression of interference artefacts."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308118696&prefLang=en_US"],"dc:language":["eng"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:308118696/308118696.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:subject":["FDML laser (Fourier-domain mode-locked laser) Spectro-temporal imaging Spectral encoding Time-stretch imaging Quantitative phase imaging (QPI) Multi-ATOM"],"dc:title":["Flow-through detection and imaging in microfluidic systems via application of the fdml laser /","Pratakumo režimo aptikimas ir vaizdinimas mikrofluidinėse sistemose, pritaikant FDML lazerį."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:11:35Z"}