{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308150850"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308150850","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Neinvaziniais vaizdiniais tyrimais ir dirbtiniu intelektu suplanuotų aritmijų abliacijos procedūrų įvertinimas /","abstract":"Background Images from computed tomography (CT) imported into specialized image processing systems perform image segmentation and integration with electroanatomic maps. Integrating non-invasive artificial intelligence (AI) and decrement evoked potential (DEEP) mapping into ablation procedures may improve substrate targeting in ischemic ventricular tachycardia (VT) ablation. Methods Patients (n=4) with ischemic cardiomyopathy and scar-related VT were included between 2024 and 2025 into the pilot observational study. Pre-procedural CT scans were processed using an AI-guided imaging platform to identify scar distribution and predicted isthmuses. High-density DEEP mapping was performed intra-procedurally. Ablation primarily targeted DEEP sites co-localizing AI-defined isthmuses. Non-inducibility was tested after the ablation of all primary targets using the 400/S2/S3/S4 stimulation protocol and pharmacological provocation testing. Results All patients were male with a mean age of 69.2 ± 5.7 years, mean left ventricular ejection fraction (LVEF) of 32.2 ± 13.2%, and a mean number of 13,67 ± 18,93 discharges of implantable cardioverter-defibrillators (ICDs). Patients presented with an average scar volume of 26.59 ± 6.96 ml, 10.5 ± 5.72 pre-defined VT-dependent isthmuses and 2 ± 1.41 primary inducible VTs per patient. Pre-procedural PAINESD risk score averaged 14.75 ± 5.12. Primarily ablation tactic resulted in VT non-inducibility in all patients. During a median follow-up of 10 ± 2.83 months (range 6-12 months), no sustained VT recurrences were observed. Freedom from non-sustained VT was 50% at 7 months. Conclusion This pilot experience suggests that combining AI-derived anatomical isthmus prediction with DEEP functional mapping is feasible and may enhance substrate targeting in ischemic VT ablation. Larger comparative studies are required to determine its impact on long-term outcomes.","abstract_html":"Background Images from computed tomography (CT) imported into specialized image processing systems perform image segmentation and integration with electroanatomic maps. Integrating non-invasive artificial intelligence (AI) and decrement evoked potential (DEEP) mapping into ablation procedures may improve substrate targeting in ischemic ventricular tachycardia (VT) ablation. Methods Patients (n=4) with ischemic cardiomyopathy and scar-related VT were included between 2024 and 2025 into the pilot observational study. Pre-procedural CT scans were processed using an AI-guided imaging platform to identify scar distribution and predicted isthmuses. High-density DEEP mapping was performed intra-procedurally. Ablation primarily targeted DEEP sites co-localizing AI-defined isthmuses. Non-inducibility was tested after the ablation of all primary targets using the 400/S2/S3/S4 stimulation protocol and pharmacological provocation testing. Results All patients were male with a mean age of 69.2 ± 5.7 years, mean left ventricular ejection fraction (LVEF) of 32.2 ± 13.2%, and a mean number of 13,67 ± 18,93 discharges of implantable cardioverter-defibrillators (ICDs). Patients presented with an average scar volume of 26.59 ± 6.96 ml, 10.5 ± 5.72 pre-defined VT-dependent isthmuses and 2 ± 1.41 primary inducible VTs per patient. Pre-procedural PAINESD risk score averaged 14.75 ± 5.12. Primarily ablation tactic resulted in VT non-inducibility in all patients. During a median follow-up of 10 ± 2.83 months (range 6-12 months), no sustained VT recurrences were observed. Freedom from non-sustained VT was 50% at 7 months. Conclusion This pilot experience suggests that combining AI-derived anatomical isthmus prediction with DEEP functional mapping is feasible and may enhance substrate targeting in ischemic VT ablation. Larger comparative studies are required to determine its impact on long-term outcomes.","abstract_has_math":false,"creators":["Radavičius, Vytautas,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:11:38Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308150850&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308150850&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308150850","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Radavičius, Vytautas,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:308150850/308150850.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/masterThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308150850&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Background Images from computed tomography (CT) imported into specialized image processing systems perform image segmentation and integration with electroanatomic maps. Integrating non-invasive artificial intelligence (AI) and decrement evoked potential (DEEP) mapping into ablation procedures may improve substrate targeting in ischemic ventricular tachycardia (VT) ablation. Methods Patients (n=4) with ischemic cardiomyopathy and scar-related VT were included between 2024 and 2025 into the pilot observational study. Pre-procedural CT scans were processed using an AI-guided imaging platform to identify scar distribution and predicted isthmuses. High-density DEEP mapping was performed intra-procedurally. Ablation primarily targeted DEEP sites co-localizing AI-defined isthmuses. Non-inducibility was tested after the ablation of all primary targets using the 400/S2/S3/S4 stimulation protocol and pharmacological provocation testing. Results All patients were male with a mean age of 69.2 ± 5.7 years, mean left ventricular ejection fraction (LVEF) of 32.2 ± 13.2%, and a mean number of 13,67 ± 18,93 discharges of implantable cardioverter-defibrillators (ICDs). Patients presented with an average scar volume of 26.59 ± 6.96 ml, 10.5 ± 5.72 pre-defined VT-dependent isthmuses and 2 ± 1.41 primary inducible VTs per patient. Pre-procedural PAINESD risk score averaged 14.75 ± 5.12. Primarily ablation tactic resulted in VT non-inducibility in all patients. During a median follow-up of 10 ± 2.83 months (range 6-12 months), no sustained VT recurrences were observed. Freedom from non-sustained VT was 50% at 7 months. Conclusion This pilot experience suggests that combining AI-derived anatomical isthmus prediction with DEEP functional mapping is feasible and may enhance substrate targeting in ischemic VT ablation. Larger comparative studies are required to determine its impact on long-term outcomes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Neinvaziniais vaizdiniais tyrimais ir dirbtiniu intelektu suplanuotų aritmijų abliacijos procedūrų įvertinimas /","Evaluation of arrhythmia ablation procedures planned using non-invasive imaging studies and artificial intelligence."]}]}],"canonical_facts":{"dc:creator":["Radavičius, Vytautas,"],"dc:date":["2026"],"dc:description":["Background Images from computed tomography (CT) imported into specialized image processing systems perform image segmentation and integration with electroanatomic maps. Integrating non-invasive artificial intelligence (AI) and decrement evoked potential (DEEP) mapping into ablation procedures may improve substrate targeting in ischemic ventricular tachycardia (VT) ablation. Methods Patients (n=4) with ischemic cardiomyopathy and scar-related VT were included between 2024 and 2025 into the pilot observational study. Pre-procedural CT scans were processed using an AI-guided imaging platform to identify scar distribution and predicted isthmuses. High-density DEEP mapping was performed intra-procedurally. Ablation primarily targeted DEEP sites co-localizing AI-defined isthmuses. Non-inducibility was tested after the ablation of all primary targets using the 400/S2/S3/S4 stimulation protocol and pharmacological provocation testing. Results All patients were male with a mean age of 69.2 ± 5.7 years, mean left ventricular ejection fraction (LVEF) of 32.2 ± 13.2%, and a mean number of 13,67 ± 18,93 discharges of implantable cardioverter-defibrillators (ICDs). Patients presented with an average scar volume of 26.59 ± 6.96 ml, 10.5 ± 5.72 pre-defined VT-dependent isthmuses and 2 ± 1.41 primary inducible VTs per patient. Pre-procedural PAINESD risk score averaged 14.75 ± 5.12. Primarily ablation tactic resulted in VT non-inducibility in all patients. During a median follow-up of 10 ± 2.83 months (range 6-12 months), no sustained VT recurrences were observed. Freedom from non-sustained VT was 50% at 7 months. Conclusion This pilot experience suggests that combining AI-derived anatomical isthmus prediction with DEEP functional mapping is feasible and may enhance substrate targeting in ischemic VT ablation. Larger comparative studies are required to determine its impact on long-term outcomes."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308150850&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:308150850/308150850.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Neinvaziniais vaizdiniais tyrimais ir dirbtiniu intelektu suplanuotų aritmijų abliacijos procedūrų įvertinimas /","Evaluation of arrhythmia ablation procedures planned using non-invasive imaging studies and artificial intelligence."],"dc:type":["info:eu-repo/semantics/masterThesis"]},"updated_at":"2026-11-19T10:11:38Z"}