{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308320095"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308320095","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Polistireno mikro- ir nanodalelių citotoksiškumo ir genotoksiškumo tyrimai žmogaus alveolinės adenokarcinomos ląstelių linijoje (A549) in vitro /","abstract":"Polystyrene micro- and nanoparticles (PS-MNPs) are plastic particles widely distributed in the environment. Many studies with various test subjects have shown that polystyrene micro- and nanoparticles can enter living organisms, including humans, via multiple routes. This raises concerns about their potential adverse effects. In this work, the cytotoxicity and genotoxicity of 1 &#956;m polystyrene microparticles and 70 nm polystyrene nanoparticles were investigated in the human alveolar adenocarcinoma cell line A549 in vitro. A mixture of acridine orange and ethidium bromide dyes was used to determine the cytotoxic effects, the alkaline and enzyme-modified comet assay was used to determine primary and oxidative DNA damage. The cytokinesis-block micronucleus assay was used to determine chromosomal damage. Different concentrations of polystyrene micro- and nanoparticles were used: 5, 10, 20, 40, 60, 80, 100 &#956;g/mL. Viability analysis showed that none of the PS-MNP concentrations caused cytotoxicity. The genotoxicity assessment using the enzyme-modified comet assay showed that PS-MP concentrations of 20 and 100 &#956;g/mL caused a statistically significant change in oxidative DNA damage, whereas none of the PS-NP concentrations induced significant DNA damage. The cytokinesis-block micronucleus assay showed that none of the PS-MNP concentrations caused a significant increase in micronuclei frequency.","abstract_html":"Polystyrene micro- and nanoparticles (PS-MNPs) are plastic particles widely distributed in the environment. Many studies with various test subjects have shown that polystyrene micro- and nanoparticles can enter living organisms, including humans, via multiple routes. This raises concerns about their potential adverse effects. In this work, the cytotoxicity and genotoxicity of 1 &amp;#956;m polystyrene microparticles and 70 nm polystyrene nanoparticles were investigated in the human alveolar adenocarcinoma cell line A549 in vitro. A mixture of acridine orange and ethidium bromide dyes was used to determine the cytotoxic effects, the alkaline and enzyme-modified comet assay was used to determine primary and oxidative DNA damage. The cytokinesis-block micronucleus assay was used to determine chromosomal damage. Different concentrations of polystyrene micro- and nanoparticles were used: 5, 10, 20, 40, 60, 80, 100 &amp;#956;g/mL. Viability analysis showed that none of the PS-MNP concentrations caused cytotoxicity. The genotoxicity assessment using the enzyme-modified comet assay showed that PS-MP concentrations of 20 and 100 &amp;#956;g/mL caused a statistically significant change in oxidative DNA damage, whereas none of the PS-NP concentrations induced significant DNA damage. The cytokinesis-block micronucleus assay showed that none of the PS-MNP concentrations caused a significant increase in micronuclei frequency.","abstract_has_math":false,"creators":["Horbačauskaitė, Vaiva,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:12:38Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308320095&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308320095&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308320095","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Horbačauskaitė, Vaiva,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:308320095/308320095.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308320095&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Polystyrene micro- and nanoparticles (PS-MNPs) are plastic particles widely distributed in the environment. Many studies with various test subjects have shown that polystyrene micro- and nanoparticles can enter living organisms, including humans, via multiple routes. This raises concerns about their potential adverse effects. In this work, the cytotoxicity and genotoxicity of 1 &#956;m polystyrene microparticles and 70 nm polystyrene nanoparticles were investigated in the human alveolar adenocarcinoma cell line A549 in vitro. A mixture of acridine orange and ethidium bromide dyes was used to determine the cytotoxic effects, the alkaline and enzyme-modified comet assay was used to determine primary and oxidative DNA damage. The cytokinesis-block micronucleus assay was used to determine chromosomal damage. Different concentrations of polystyrene micro- and nanoparticles were used: 5, 10, 20, 40, 60, 80, 100 &#956;g/mL. Viability analysis showed that none of the PS-MNP concentrations caused cytotoxicity. The genotoxicity assessment using the enzyme-modified comet assay showed that PS-MP concentrations of 20 and 100 &#956;g/mL caused a statistically significant change in oxidative DNA damage, whereas none of the PS-NP concentrations induced significant DNA damage. The cytokinesis-block micronucleus assay showed that none of the PS-MNP concentrations caused a significant increase in micronuclei frequency."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Polistireno mikro- ir nanodalelių citotoksiškumo ir genotoksiškumo tyrimai žmogaus alveolinės adenokarcinomos ląstelių linijoje (A549) in vitro /","Analysis of in vitro cytotoxicity and genotoxicity of polystyrene micro- and nanoparticles in human alveolar adenocarcinoma cell line a549."]}]}],"canonical_facts":{"dc:creator":["Horbačauskaitė, Vaiva,"],"dc:date":["2026"],"dc:description":["Polystyrene micro- and nanoparticles (PS-MNPs) are plastic particles widely distributed in the environment. Many studies with various test subjects have shown that polystyrene micro- and nanoparticles can enter living organisms, including humans, via multiple routes. This raises concerns about their potential adverse effects. In this work, the cytotoxicity and genotoxicity of 1 &#956;m polystyrene microparticles and 70 nm polystyrene nanoparticles were investigated in the human alveolar adenocarcinoma cell line A549 in vitro. A mixture of acridine orange and ethidium bromide dyes was used to determine the cytotoxic effects, the alkaline and enzyme-modified comet assay was used to determine primary and oxidative DNA damage. The cytokinesis-block micronucleus assay was used to determine chromosomal damage. Different concentrations of polystyrene micro- and nanoparticles were used: 5, 10, 20, 40, 60, 80, 100 &#956;g/mL. Viability analysis showed that none of the PS-MNP concentrations caused cytotoxicity. The genotoxicity assessment using the enzyme-modified comet assay showed that PS-MP concentrations of 20 and 100 &#956;g/mL caused a statistically significant change in oxidative DNA damage, whereas none of the PS-NP concentrations induced significant DNA damage. The cytokinesis-block micronucleus assay showed that none of the PS-MNP concentrations caused a significant increase in micronuclei frequency."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308320095&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:308320095/308320095.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Polistireno mikro- ir nanodalelių citotoksiškumo ir genotoksiškumo tyrimai žmogaus alveolinės adenokarcinomos ląstelių linijoje (A549) in vitro /","Analysis of in vitro cytotoxicity and genotoxicity of polystyrene micro- and nanoparticles in human alveolar adenocarcinoma cell line a549."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:12:38Z"}